Hier Klicken für das PDF Dokument!!!

     GPFC250 Commercial/GPFM250 Medical
     250 Watt Global Performance Switchers
                                                                        FEATURES:
                                                                        ·   3.6 watts/cu.in. power density
                                                                        ·   Compact size (5.0" x 8.0" x 1.75")
                                                                        ·   Power factor corrected to IEC 1000-3-2, Class A
                                                                        ·   Less than 300 µA leakage
                                                                        ·   Conducted EMI exceeds FCC Class B and CISPR 22
                                                                            Class B (Commercial models) and CISPR 11 Class B
                                                                            (Medical models)
                                                                        ·   Commercial Approved to UL1950, IEC950, EN60950
                                                                            and CSA 22.2 No. 950
                                                                        ·   Medical Approved to UL2601-1, IEC601-1/60601-1
                                                                            and CSA-C22.2 No. 601.1
                                                                        ·   2-year warranty
     SPECIFICATIONS:                                                    ·       marked to LVD
     Ac Input
     85-264 Vac, 47-63 Hz single phase.                                 EMI/EMC Compliance
     Input Current                                                      All models include built-in EMI filtering to meet emissions
     Maximum input current 3.7 A at 90 Vac, 60 Hz with                  requirements:
     full rated load. Input current harmonic content meets              EMI SPECIFICATIONS          COMPLIANCE LEVEL
     the requirements of IEC1000-3-2 Class A for all                    Conducted Emissions GPFC250 EN55022 Class B; FCC Class B
     load conditions.                                                   Conducted Emissions GPFM250 EN55011 Class B; FCC Class B
                                                                        Static Discharge            EN61000-4-2, 6 kV contact, 8 kV air
     Hold-upTime                                                        RF Field Susceptibility     EN61000-4-3, 3 V/meter
     25 ms minimum from loss of ac input at full load, nominal          Fast Transients/Bursts      EN61000-4-4, 2 kV, 5 kHz
     line (115 Vac).                                                    Surge Susceptibility        EN61000-4-5, 1 kV diff., 2 kV com.
     Minimum Load: No minimum load required                             Inrush Current
     Output Power                                                       Inrush 240 Vac is less than 37 A, averaged over the first
     250 W fan cooled, 180 W convection                                 ac half-cycle under cold start conditions. Limiting pro-
     Overload Protection                                                vided by internal thermistors.
     Fully protected against short circuit and output overload.         Fan Output
     Short circuit protection is cycling type power limit or            An additional 12 Vdc, 250 mA output suitable for power-
     foldback type depending on model and output. Recovery              ing a dc fan is included in all models.
     after fault is automatic. Individual output current limits are     Thermal Shutdown
     a function of load distribution and degree of overload.            Provided as a standard feature. Designed to protect unit
     Output Noise                                                       from prolonged over temperature.
     0.5% rms, 1% pk-pk, 20 MHz Bandwidth, differential                 Power Fail
     mode. Measured with noise probe directly across output             TTL or CMOS compatible output goes low (<0.5 V) 8 ms
     terminals of the power supply.                                     before output voltage drops more than 4% below nominal
     Transient Response                                                 voltage upon loss of ac power. The signal is factory set to
     Main Output­500 ms typical response time for return to             trip when input power can no longer sustain the output.
     within 0.5% of final value for a 50% load step change, Di/         Temperature Coefficient
     Dt< 0.2 A/ms. Maximum voltage deviation is 3.5%. Load              0.03% / °C typical on all outputs.
     must not go below stated minimum.
                                                                        Leakage Current
     Remote Sense                                                       70µA under normal conditions (132 Vac @ 60 Hz).
     Provided as a standard feature. Capable of compensating            Maximum under single fault conditions (254 Vac @ 50
     for 0.25 V total of cabling losses in voltage.                     Hz), 130 µA.
     Overvoltage Protection                                             Power Good
     Built in on all models. Output voltage decay is dependent          TTL/CMOS compatible output goes high more than 100
     upon loading.                                                      ms after V1 reaches the under voltage threshold and
     Voltage Adjustment                                                 should assure that sufficient energy is stored in the input
     Main output ±5%.                                                   section to provide normal power fail/shutdown. The signal
     Efficency                                                          will fall to a low state (<0.5 V) when V1 goes below 95%
     Minimum 80% on 12-48 V units, 75% on 5 & 3.3 V units at            of the rated voltage.
     full rated load.                                                   External Off
     Input Protection                                                   TTL/CMOS compatible input shuts down power converter.
     Internal ac fuses provided on all models. Fuses do not             A logic high (>2.7 V with 400 uA source) shuts down the
     blow on overload or short circuit--fuses blow only if              power converter. A logic low (<0.5 V) or an open circuit
     catastrophic failure occurs in the unit.                           allows the supply to run.
                           CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
                               Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de




68
GPFC250 Commercial/GPFM250 Medical 250 Watt Single Output

 Commercial       Medical                                              Voltage       Output              Output
 Model            Model               Output No.    Output            Adjustment   Maximum (A)          Peak (B)        OVP Setpoint         Total Regulation          Notes
 GPFC250-3.3      GPFM250-3.3               1        3.3 V                ±5%         36 A                50 A            6.2 ± 0.6 V               2%                       C

 GPFC250-5        GPFM250-5                 1        5.1 V                ±5%         36 A                50 A            6.2 ± 0.6 V               2%                       C

 GPFC250-12       GPFM250-12                1        12 V                 ±5%         15 A                21 A            14 ± 1.1 V                2%                       C

 GPFC250-15       GPFM250-15                1        15 V                 ±5%         12 A               16.7 A          18.5 ± 1.5 V               2%                       C

 GPFC250-24       GPFM250-24                1        24 V                 ±5%         7.5 A              10.5 A           28 ± 2.5 V                2%                       C

 GPFC250-28       GPFM250-28                1        28 V                 ±5%         6.5 A               9A              34 ± 2.8 V                2%                       C

 GPFC250-48       GPFM250-48                1        48 V                 ±5%         3.8 A              5.3 A            55 ± 4.0 V                2%                       C
A. Output rating with unrestricted convection cooling.
B. Output rating with 26cfm airflow.
C. Add "C" suffix for factory installed cover with fan option.

GPFC250/GPFM250 MECHANICAL SPECIFICATIONS
INPUT:
TB1
  6-32, 3 PIN TERMINAL BLOCK
  PIN 1) AC LINE
  PIN 2) AC NEUTRAL
  PIN 3) AC GROUND

SIGNALS: J2
  AMP P.C.B. HEADER P/N 640456-5
  MATING CONNECTOR P/N640440-5
  PIN 1) DC GOOD
  PIN 2) POWER FAIL
  PIN 3) EXT OFF
  PIN 4) +SENSE
  PIN 5) -SENSE
FAN
  AMP P.C.B. HEADER P/N 640456-2
  MATING CONNECTOR P/N 640440-2
  PIN 1) -
  PIN 2) +
OUTPUT:
TB2
  6-32, 4 PIN TERMINAL BLOCK 0.375
          [9.53mm]CTR
  AN OPTIONAL BUS BAR WITH 10-32
  SCREWS ON HIGH-CURRENT MODELS
  IS AVAILABLE BY ADDING -B TO
  MODEL NUMBER
  PINS 1-2) +Vout
  PINS 3-4) RETURN
  16A MAXIMUM RECOMMENDED
CURRENT PER CONNECTOR PIN.
  MAX. SCREW PROTRUSION ABOVE
  CHASSIS =0.120" [3.05MM].
OPTIONAL: COVER/FAN ASSEMBLY #09-250CF
CAN BE INCLUDED BY ADDING -C TO
MODEL NUMBER                           CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
WEIGHT: 2.9 LBS. [1.32 kg] MAX.          Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de
TOLERANCES: X.XX=0.030 [0.76mm]
                 X.XXX+0.010 [0.25 mm]
 Environmental
                                Operating                Non-operating
 Specification
 Temperature (A)                 0 to 50oC                  -40 to +85oC
 Humidity (A)                  0 to 95% RH                  0 to 95% RH             A. Units should be allowed to warm up/operate under non-condensing conditions
                                                                                       before application of power. Derate output current and total output power by 2.5%
 Shock (B)                         20 gpk                        40 gpk                per °C above 50°C.
                                                                                    B. Random vibration--10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3
 Altitude                    -500 to 10,000 ft          -500 to 40,000 ft
                                                                                       orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating.
 Vibration (C)              1.5 grms, 0.003 g2/Hz      5 grms, 0.026 g2/Hz          C. Shock testing--half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes,