Hier Klicken für das PDF Dokument!!!

     GPC140 Commercial/GPM140 Medical
     140 Watt Global Performance Switchers
                                                                        FEATURES:
                                                                        · Wide-range ac input 85-264 Vac
                                                                        · 2-year warranty
                                                                        · Conducted EMI exceeds FCC Class B and CISPR 22
                                                                          Class B (Commercial models) and CISPR 11 Class B
                                                                          (Medical models)
                                                                        · Single outputs
                                                                        · Commercial Approved to UL1950, IEC950,
                                                                          EN60950 and CSA22.2-234 L3
                                                                        · Medical Approved to UL2601-1, IEC601-1 and
                                                                          CSA22.2 No. 601
                                                                        ·     marked to LVD


     SPECIFICATIONS:
     Ac Input                                                           Output Noise
     85-264 Vac, 47-63 Hz single phase.                                 0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential
                                                                        mode. Measured with noise probe directly across output
     Input Current                                                      terminals of the power supply.
     Maximum input current at 120 Vac, 60 Hz with full rated
     output load: 3.7 A                                                 Transient Response
                                                                        Main output--500 µs typical response time for return to
     Hold-Up Time                                                       within 0.5% of final value for a 50% load step change. i/
     20ms minimum from loss of ac input at full load, nominal           t<0.2 A/µs. Maximum voltage deviation is 3.5%. Startup/
     line (115 Vac).                                                    shutdown overshoot less than 3%.
     Output Power                                                       Remote Sense
     140 W convection; 160 W with air flow. Peak ratings are            Provided as a standard feature.
     for 60 s maximum duration, 10% duty cycle.
                                                                        Voltage Adjustment
     Overload Protection                                                Built-in potentiometer adjusts voltage ±5%.
     Fully protected against short circuit and output overload.
     Short circuit protection is cycling type power limit on            Overload Protection
     output 1. Recovery after fault is automatic.                       Factory set to begin power limiting at approximately 175 W.
     Overvoltage Protection                                             EMI/EMC Compliance
     Main outputs: 130% ± 15% typical.                                  All models include built-in EMI filtering to meet the
                                                                        following emissions requirements:
     Efficiency                                                         EMI SPECIFICATIONS           COMPLIANCE LEVEL
     70% at full rated load, nominal input voltage, depending           Conducted Emissions GPC140   EN55022 Class B; FCC Class B
     on model and load distribution.                                    Conducted Emissions GPM140   EN55011 Class B; FCC Class B
                                                                        Static Discharge             EN61000-4-2, 6 kV contact, 8 kV air
     Input Protection                                                   RF Field Susceptibility      EN61000-4-3, 3 V/meter
     Internal ac fuse provided. Designed to blow only if a              Fast Transients/Bursts       EN61000-4-4, 2 kV, 5 kHz
     catastrophic failure occurs in the unit.                           Surge Susceptibility         EN61000-4-5, 1 kV diff., 2 kV com.

     Inrush Current                                                     Commercial Leakage Current
     Inrush is limited by internal thermistors. Inrush at 240 Vac,      0.95 mA 254 Vac @ 60 Hz input.
     averaged over the first ac half-cycle under cold start
     conditions will not exceed 60 A.                                   Commercial Safety
                                                                        Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950
     Temperature Coefficient                                            and EN60950. UL file #E135803 commercial; CSA
     0.03%/°C typical on all outputs.                                   #LR46516 all models. The output(s) are intended for
                                                                        safety earthed Signal Output and Intermediate Circuits
     Thermal Shutdown                                                   only. All dc outputs are SELV under normal and single
     Provided as a standard feature. Designed to protect unit           fault conditions.
     from prolonged overtemperature.
                                                                        Medical Leakage Current
     Environmental                                                      60 µA 254 Vac @ 60 Hz input.
     Designed for 0 to 50°C operation at full rated output
     power; derate output current and total output power by             Medical Safety
     2.5% per °C above 50°C. See Environmental and                      Approved to UL2601, CSA22.2 No. 601 Level 3 and
     Packaging Specifications on next page.                             IEC601. UL file E116994; CSA #LR46516. The output(s)
                                                                        are intended for safety earthed Signal Output and
     Power Fail                                                         Intermediate Circuits only. The output(s) are not accept-
     TTL- or CMOS-compatible output goes low (< 0.5 V) 5 ms             able for patient connection without additional isolation. All
     before output voltage drops more than 4% below                     dc outputs are SELV under normal and single fault
     nominal voltage upon loss of ac power. The signal is               conditions.
     factory set to trip on 84 to 94 Vac brown-out depending
     upon incoming line impedance and distortion. Other
     settings are available to the user through adjustment of
     built-in potentiometer.

                            CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
                               Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de

56
GPC140 Commercial/GPM140 Medical 140 Watt Multiple Output

 Commercial            Medical                                  Output                 Output                    Output
 Model                 Model                  Output           Minimum               Maximum (B)               Maximum (C)                Peak           Noise P-P           Total Regulation (A)
 GPC140-5              GPM140-5                  5V                 0A                     26 A                      30 A                 32 A              50 mV                    2%

 GPC140-12             GPM140-12                 12 V               0A                    11.7 A                    13.4 A               14.6 A            120 mV                    2%

 GPC140-15             GPM140-15                 15 V               0A                     9.3 A                    10.7 A               11.7 A            150 mV                    2%

 GPC140-24             GPM140-24                 24 V               0A                     5.8 A                     6.7 A                7.3 A            240 mV                    2%

 GPC140-28             GPM140-28                 28 V               0A                      5A                       5.7 A                6.3 A            280 mV                    2%

A.Total regulation is defined as the maximum deviation from the nominal voltage for all steady-state conditions of initial voltage setting, input line voltage and output load.
B. Unrestricted natural convection cooling.
C. Requires 26cfm moving air.




GPC140/GPM140 MECHANICAL SPECIFICATIONS




 Environmental
                                     Operating                        Non-operating
 Specification
 Temperature (A)               See individual specs                     -40 to +85oC
 Humidity (A)                       0 to 95% RH                         0 to 95% RH
                                                                                                          A. Units should be allowed to warm up/operate under non-condensing conditions
 Shock (B)                              20 gpk                              40 gpk                           before application of power.
                                                                                                          B. Random vibration--10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3
 Altitude                        -500 to 10,000 ft                   -500 to 40,000 ft                       orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating.
                                                                                                          C. Shock testing--half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes,
 Vibration (C)                 1.5 grms, 0.003 g2/Hz                5 grms, 0.026 g2/Hz
                                                                                                             total 6 shocks.


                             CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
                                   Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de