Hier Klicken für das PDF Dokument!!!

     GPC41 Commercial/GPM41 Medical
     41 Watt Global Performance Switchers
                                                                         FEATURES:
                                                                         · Ultra small (2.00" x 4.00" x 1.50")
                                                                         · Wide-range ac input 85-264 Vac
                                                                         · 2-year warranty
                                                                         · Conducted EMI exceeds FCC Class B and CISPR 22
                                                                           Class B (Commercial models) and CISPR 11 Class B
                                                                           (Medical models)
                                                                         · Commercial Approved to UL1950, IEC950, EN60950
                                                                           and CSA22.2-234 L3
                                                                         · Medical Approved to UL2601-1, IEC601-1
                                                                           and CSA22.2 No. 601
                                                                         ·     marked to LVD
     SPECIFICATIONS:
     Ac Input
     85-264 Vac, 47-63 Hz single phase.

     Input Current
     Maximum input current at 120 Vac, 60 Hz with full rated              Output Noise
     output load: 1.3 A                                                   0.5% rms, 1% pk-pk, 20 MHz bandwidth, differential
                                                                          mode. Measured with noise probe directly across output
     Hold-Up Time                                                         terminals of the power supply.
     20 ms minimum from loss of ac input at full load, nominal
     line (115 Vac).                                                      Transient Response
                                                                          Main output--500 µs typical response time for return to
     Output Power                                                         within 0.5% of final value for a 50% load step change. i/
     40 W continuous, 50 W peak. Peak ratings are for 60 s                t<0.2 A/µs. Maximum voltage deviation is 3.5%. Startup/
     maximum duration, 10% duty cycle. During peak load                   shutdown overshoot less than 3%.
     condition, output regulation may exceed total regulation
     limits.                                                              EMI/EMC Compliance
                                                                          All models include built-in EMI filtering to meet the
     Overload Protection                                                  following emissions requirements:
     Fully protected against short circuit and output overload.           EMI SPECIFICATIONS           COMPLIANCE LEVEL
     Short circuit protection is cycling type power limit.                Conducted Emissions GPC41    EN55022 Class B; FCC Class B
     Recovery after fault is automatic. Factory set to begin              Conducted Emissions GPM41    EN55011 Class B; FCC Class B
     power limiting at approximately 55 W. See output ratings             Static Discharge             EN61000-4-2, 6 kV contact, 8 kV air
     chart for additional notes or conditions.                            RF Field Susceptibility      EN61000-4-3, 3 V/meter
                                                                          Fast Transients/Bursts       EN61000-4-4, 2 kV, 5 kH
     Overvoltage Protection                                               Surge Susceptibility         EN61000-4-5, 1 kV diff., 2 kV com.
     See output ratings chart.
                                                                          Commercial Leakage Current
     Efficiency                                                           60 µA single fault; 60 Hz input.
     69-77% at full rated load, nominal input voltage, depend-
     ing on model.                                                        Commercial Safety
                                                                          Approved to UL1950, CSA22.2 No. 234 Level 3, IEC950
     Turn-on Time                                                         and EN60950. UL file #E135803 commercial; CSA
     Less than 1 s at 120 Vac, 25°C (inversely proportional to            #LR46516 all models. The output is intended for safety
     input voltage).                                                      earthed Signal Output and Intermediate Circuits only. All
                                                                          dc outputs are SELV under normal and single fault
     Input Protection                                                     conditions.
     Requires external ac line fusing. A 2.5 A, 250 V rated fuse
     with I2t > 20 is recommended.                                        Medical Leakage Current
                                                                          35 µA , 254 Vac 10 Hz input.
     Inrush Current
     Inrush is limited by internal thermistor. Inrush at 240 Vac          Medical Safety
     under cold start conditions will not exceed 34 A.                    Approved to UL2601, CSA22.2 No. 601 Level 3, IEC601.
                                                                          UL file E116994; CSA #LR46516. The output(s) are
     Temperature Coefficient                                              intended for safety earthed Signal Output and Intermedi-
     0.03%/°C typical on all outputs.                                     ate Circuits only. The output(s) are not acceptable for
                                                                          patient connection without additional isolation. All dc
     Environmental                                                        outputs are SELV under normal and single fault condi-
     Designed for 0 to 50°C operation at full rated output                tions.
     power; derate output current and total output power by
     2.5% per °C above 50°C. See Environmental and
     Packaging Specifications on next page.



                            CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
                                 Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de

28
GPC41 Commercial/GPM41 Medical 41 Watt Single Output
Commercial        Medical                                      Minimum        Load               Initial Setpoint           OVP
Model             Model               Output    Current         Load        Regulation              Tolerance              Setpoint          Ripple and Noise
GPC41-5           GPM41-5               5.1 V     6.0 A             0.15        0.75%                    2%               6.2 ± 0.6 V                  1%

GPC41-12          GPM41-12              12 V      3.3 A             0.03        0.75%                    2%                14 ± 1.0 V                  1%

GPC41-15          GPM41-15              15 V      2.7 A             0.03        0.75%                    2%                19 ± 1.5 V                  1%

GPC41-24          GPM41-24              24 V      1.7 A             0.01        0.75%                    2%                28 ± 2.5 V                  1%

GPC41-28          GPM41-28              28 V      1.4 A             0.01        0.75%                    2%                34 ± 2.8 V                  1%




GPC41/GPM41 MECHANICAL SPECIFICATIONS




Environmental
                            Operating            Non-operating
Specification
Temperature (A)      See individual specs         -40 to +85oC
Humidity (A)            0 to 95% RH               0 to 95% RH
                                                                           A. Units should be allowed to warm up/operate under non-condensing conditions
Shock (B)                    20 gpk                   40 gpk                  before application of power.
                                                                           B. Random vibration--10 to 2000Hz, 6dB/octave roll-off from 350 to 2000Hz, 3
Altitude              -500 to 10,000 ft         -500 to 40,000 ft             orthogonal axes. Tested for 10 min./axis operating and 1 hr./axis non-operating.
                                        2
                                                                           C. Shock testing--half-sinusoidal, 10 ± 3 ms duration, ± direction, 3 orthogonal axes,
Vibration (C)        1.5 grms, 0.003 g /Hz      5 grms, 0.026 g2/Hz           total 6 shocks.



                    CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
                        Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de