                                                                                                                                                                               146-1944




                                                                                                                                         Series HSF 600W /1200W /1500W




             HIGH DENSITY LOW COST
                 HOT SWAP POWER SUPPLIES FROM KEPCO
      Two 1200/1500 Watt and five 600                              a-c input mains voltage. Output                               system. The rack housing has space
      Watt high-power models join the                              power ranges from just under 900W                             for four modules allowing users
      Kepco HSF-group of plug-in,                                  for the 48V model running on                                  to configure various redundant
      redundant-capable, hot-swappable                             85-132V a-c, to just over 1500W for                           systems: two 1+1 redundant systems
      power supplies. Offered in 12 Volt and                       the 48V model running on                                      of up to 1500 watts each, or a single
      higher output models, using efficient                        170-265V a-c mains. The 600 Watt                              3+1 redundant system for up to
      high frequency forward conversion                            models offer full power operation                             4500 watts, or a single parallel
      with power factor correction, they                           from 85-264V a-c input.                                       combination producing up to 6,000
      operate from nominal 100V a-c or                                                                                           watts of d-c power. Built-in current
      240V a-c power mains without                                 These Kepco HSF models plug into                              balancing and OR-ing
      switching. The power rating of the                           a standard 3U x 19" housing, model                            diodes allow all these
      two 1200/1500 Watt models depends                            RA 19-4C, to facilitate hot swapping                          configurations.
      on the model (24V or 48V) and the                            in a fault-tolerant redundant power


       HSF 600W MODEL TABLE
NEW
                                                     ADJUSTMENT               EXTERNAL                     OVP                OUTPUT                  CURRENT
                                    OUTPUT            RANGE ((1)        PROGRAMMING RANGE((2)            SETTING             CURRENT                  LIMIT (3)       RIPPLE/NOISE
        MODEL                        Volts              Volts                   Volts                     Volts                Amps                    Amps              mV p-p

        HSF 12-53                     12               0-13.8                 0-14.4                  16.8-19                    53                  55.6-68.9         180/220
        HSF 15-43                     15               0-17.4                 0-18.0                     21-24                   43                  45.1-55.9         180/220
        HSF 24-27                     24               0-28.2                 0-28.8                 33.6-38.4                   27                  28.3-35.1         220/320
        HSF 28-23                     28               0-33.0                 0-33.6                  39.2-44                    23                  24.1-29.8         220/320
        HSF 48-13                     48               0-52.2                 0-52.8                  57.6-60                    13                  13.7-16.9         220/320
      (1) Front panel trimpot.   (2) 0-6V External voltage source (0-5.5V for 48 Volt model).    (3) Square type. After cause is removed, output voltage restored automatically.



       HSF 1200W /1500W MODEL TABLE
                                              ADJUSTMENT          OVP          OUTPUT             OUTPUT            OUTPUT              OUTPUT              CURRENT
                                 OUTPUT          RANGE          SETTING       CURRENT            CURRENT            POWER               POWER                LIMIT      RIPPLE/NOISE
        MODEL                     Volts           Volts          Volts          Amps               Amps              Watts               Watts               Amps          mV p-p
        Condition, a-c input                                                  85-132V a-c       170-265V a-c       85-132V a-c        170-265V a-c
        HSF 24-50                  24         16.8-30.5         32-35           37.5                50                900               1200                 55-65       250/350
        HSF 48-32                  48         33.6-54.0         56-60           18.7                32               897.6              1536              33.6-36.8      350/450

                                                                   CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
                                                                   Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
                                                                   info@compumess.de · www.compumess.de · www.netzteile.de
  HSF 600W /1200W /1500W GENERAL SPECIFICATIONS                                                                     HSF 600W /1200W /1500W INPUT CHARACTERISTICS
          SPECIFICATION                            600W           1200W/1500W                 CONDITION                  SPECIFICATION             600W       1200W/1500W            CONDITION

 Temperature                 Operating                   -10 to +40°C                 See the power                 Nominal Input                   100-120V a-c,                 0~100% load,
                               Start Up                  -20 to -10°C               rating plot for oper.           Voltage                         200-240V a-c                  -10 to +40°C
                                                                                     at reduced power
                                Storage                  -30 to +75°C                                               Input Voltage                    85~264V a-c                    Rated load
                                                                                     up to 65°C, Fig 1              Range                           110-370V d-c
 Humidity           Operating/Storage                10 to 95% RH                     Non-condensing                Input Frequency                    47~63Hz                      Rated load
 Safety                                      UL: UL60950-1; UL: UL60950-1;             Ambient temp                 Range
                                               1st Edition    3rd Edition              50°C maximum                 Input Current max           8.4A rms       12A rms             100-120V a-c
                                              CSA: C22.2      CSA: C22.2
                                                                                                                                        max     4.2A rms    10A rms
                                             No. 60950-1-03; No. 60950-00;
                                              1st Edition     1st Edition                                                                      (8A for 24V (8A for 24V             200-240V a-c
                                                  TUV:           TUV:                                                                            model)      model)
                                              EN60950-1;      EN60950-1;
                                                                 2000                                               Surge Current        typ      15A                15A            100V a-c,
                                                  2001
                                                                                                                                                30A first          20A first     100% load, 25°C
 Conducted Noise                             FCC Class B; VCCI Class B                                                                           surge              surge
                                              EN55011-B EN55022-B
                                                                                                                                         typ      30A                30A            240V a-c,
 Radiated Noise                              FCC Class B; VCCI Class B                                                                          60A first          20A first     100% load, 25°C
                                              EN55011-B EN55022-B                                                                                surge              surge
 Input Harmonics                Current              EN61000-3-2                                                    Leakage                    0.45 mA typ 0.30 mA typ          at 120V a-c 60 Hz
                                                                                                                    Current                    0.75 mA max 0.75 mA max              EN60950
 Immunity                                          EN50082-2
                                                                                                                                                     0.60 mA typ                at 240V a-c 60 Hz
  ESD Immunity                                  EN61000-4-2 level 4                  Normal operation                                                0.75 mA max                    EN60950
   Radiation Field Immunity                     EN61000-4-3 level 3                  Normal operation               Power Factor         typ                0.99                    100V a-c,
   Fast Transient/Burst Immunity                EN61000-4-4 level 3                  Normal operation                                                                              rated output
                                                                                                                                         typ                0.95                    240V a-c,
   Surge Immunity                               EN61000-4-5 level 4                      No damage                                                                                 rated output
   Conducted Noise Immunity                     EN61000-4-6 level 3                  Normal operation               Switching           nom           140 KHz
   Magnetic Field Immunity                      EN61000-4-8 level 4                  Normal operation               Frequency
   Voltage Dips/Short                               EN61000-4-11                     Normal operation               Input Fuse                 250V, 15A      250V, 25A
   Interruption Immunity                                                                                            Value
 Withstand             Input to output                    3.0KV a-c                    Cutout current
 Voltage                                                 for 1 minute                    20 mA (1)
                      Input to ground                                                  Cutout current
                                                                                                                    HSF 600W /1200W /1500W OUTPUT CHARACTERISTICS
                                                          2.0KV a-c
                                                         for 1 minute                    20 mA (1)                      SPECIFICATION              600W       1200W/1500W            CONDITION

                    Output to ground                       500V a-c                    Cutout current               Source               typ              ±0.1%                   85-132V a-c or
                                                         for 1 minute                   100 mA (1)                  Effect               max              ±0.2%                    190-264V a-c
 Dimensions                         mm          132.5 x 108.9 x 482.6                                               Load                 typ     ±0.3%             ±1.5%           0% to 100%
 HxWxD                           inches         5.2" x 4.228" x 16.86"                                              Effect                                                        load changes
                                                                                                                                         max     ±0.6%             ±2.0%
 Weight                                             4.1 Kg, 9.0 lbs.
                                                                                                                    Temperature          typ              ±0.5%
 Cooling                                         Forced air flow, fan                                               Effect                                                         -10 to +40°C
                                                                                                                                         max              ±1.0%
 Mounting                                        Plug-in rack housing                 Model: RA19-4C
                                                                                                                    Combined             typ              ±0.9%                Includes source, load
(1) Temperature: 15°C to 35°C and humidity: 10% to 85% RH.                                                          Effect                                                       and temperature
                                                                                                                                         max              ±1.8%
                                           FIGURE 1                                                                 Time Effect          typ              0.2%                     0.5-8 hr.
                              Output Power vs. Ambient Temperature                                                  (drift)              max                                     max load, 25°C
                                                                                                                                                          0.5%
100%                                                       100%
                                                                                                                    Transient                                                      50% to rated
80%                                                        80%
                                                                                                                    Recovery                 ±4%                                  output current
                                                                                                                    Characteristic                                                Transient time
60%                                                        60%                                                      Recovery Time max         1ms                                    >50µsec

                600W Models                                                1200W /1500W                             Start Up Time     280 msec 300 msec
40%                                                        40%
                                                                              Models                                                     typ      typ                                100V a-c
20%                                                        20%
                                                                                                                                      350 msec 450 msec
                                                                                                                                        max       max
                                                                                                                                      100 msec 250 msec
  -20°C -10°C   0   10°C 20°C 30°C 40°C 50°C 60°C 65°C       -20°C -10°C   0   10°C 20°C 30°C 40°C 50°C 60°C 65°C
                                                                                                                                         typ      typ                                200V a-c
                          THE POWER SUPPLY WILL START UP BETWEEN -20 TO -10°C                                                         150 msec 400 msec
                              BUT MAY NOT MEET PUBLISHED SPECIFICATIONS
                                                                                                                                        max       max
                     AN ISO 9001 COMPANY                                                                            Hold Up Time         typ     30ms              10ms
                                                                                                                                                                                     100V a-c
                                                                                                                                         min     20ms               7ms
                                                                                                                                         typ     40ms              10ms
                                                                                                                                                                                    200V a-c
                                                                                                                                         min     20ms               7ms
                                                                                                                    Efficiency 100V a-c               80% min.                       100V a-c
                                                                                                                                 200V a-c             84% min.                       200V a-c

                                                                                    CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
                                                                                    Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
                                                                                    info@compumess.de · www.compumess.de · www.netzteile.de