Hier Klicken für das PDF Dokument!!!

                                                     An                         Company




                                                                                    iM Series II
                                                                                AC Power Source
                                                                                    3 kVA-15 kVA
                                                                          Economical AC Power



                                           Powerful yet intuitive AC Power Source
 Easy to Use AC Power Source               The iM Series II represents is based on the popular iX Series AC source/analyzer but
    Simple menu operation                  is simpler in operation while offering the same voltage, current and power capability
                                           at a reduced price. By combining only the key AC capabilities of the iX Series, the iM
 3000 VA - 15000 VA of Output Power        Series II systems are capable of handling most generic AC power applications more
    Capable of handling a wide range of    economically.
    loads with 0 to 1 power factor         The iM Series II can be used as a bench top instrument and is also is rackmountable. It's
 Dual Voltage Ranges                       compact 4U chassis design minimizes required rack space for this power level. All AC
    Offers 150Vrms and 300Vrms output      input and output connections are made at the rear of the unit leaving a clean uncluttered
    ranges                                 front panel for the user to interact with.
 Constant Power Mode                       Using a state-of-the-art digital signal processor in conjunction with precision high
    Provides additional current at lower   resolution A/D converters, the iM Series II provides accurate output voltage and load
    voltages (See current voltage curve)   regulation.

 High Peak Current Capability              Easy To Use Controls
    Supports high crest factor loads and   The iM Series II is microprocessor controlled but retains a familiar `analog control' feel
    startup currents.                      using a large rotary knob to set output parameters. This knob is controlled by a dynamic
 Compact Design                            rate change algorithm that combines the benefits of precise control over small parameter
    5 KVA power in 7" (4U) Rack space      changes with quick sweeps through the entire range. Additional functions are grouped
                                           logically and are directly accessible from the keypad. A large backlit LCD display shows
 Remote Control                            setup parameters for operator feedback.
    Standard RS232 and USB interfaces




www.california-instruments.com
                                               An                    Company



   iM Series II - Specifications
 Operating Modes
Output Mode:                              AC
 AC Output
Frequency:                                Range: 16.00-1000 Hz (Note: Voltage on 300 V range derates from 300 Vrms max at 500 Hz to 150 Vrms max at 1000 Hz; See V-F rating chart. below)
Total Power:                              3001iM: 3000 VA, 5001iM: 5000 VA, 10001iM: 10000 VA, 15001iM: 15000 VA, 15003iM: 5000 VA/ø 3ø
Load Power Factor:                        0 to unity at full output VA
                                                                                            Load Regulation
                                                                                                                         < 0.2%
                                                                                            (with ALC on):
                                            Range:         V Low           V High
Voltage Ranges:                                                                             Load Regulation              < 0.5% DC to 100 Hz, < 0.6% 100 Hz to 500 Hz in high voltage range,
                                            AC             0-150 V         0-300 V          (with ALC off ):             < 2.2% 100 Hz to 500 Hz in low voltage range, < 3% 500 Hz to 1000 Hz
                                                                                            Line Regulation:             < 0.1% for 10% line change
Output Noise (20 kHz to 1 MHz): < 250 mVrms typ., < 500 mVrms max.
Harmonic Distortion (Linear):             < 1% from 16 - 66 Hz, < 2% at 400 Hz, < 3% at 800 Hz (Full resistive load)
DC Offset:                                < 20 mV                                 External Amplitude Modulation:                     Depth: 0 - 10 %, Frequency: DC - 2 KHz
Isolation Voltage:                        300 Vrms output to chassis
 AC Current
                                            Model                 3001iM            5001iM            10001iM            15001iM                  15003iM 3ø
                                            300 V range           11.1              18.5              37.0               55.5                     18.5
Steady State AC Current:
                                            150 V range           22.2              37.0              74.0               111.0                    37.0

                                          Note: Constant power mode provides increased current at reduced voltage (See chart below)

                                            Model                 3001iM            5001iM           10001iM            15001iM                       15003iM 3ø
Peak Repetitive AC Current:                 High range            96.0              96.0             192.0              288.0                         96.0
                                            Low range             110.0             110.0            220.0              330.0                         110.0

 Settings
                                          Voltage (rms): ± 0.2 of range, 16 to 1000 Hz, Frequency: ± 0.01 % of programmed value, Current Limit: ± 0.5 % of programmed
Accuracy:
                                          value, Phase: < 1.5° with balanced load at 50/60 Hz
                                          Voltage (rms): 100 mV, Frequency: 0.01 Hz from 16 - 81.91 Hz, 0.1 Hz from 82.0 - 819.1 Hz, 1 Hz from 820-1000 Hz, Current Limit:
Resolution:
                                          0.1 A, Phase, 0.1°
Output Relay:                             Push-button controlled or bus controlled output relay




   Constant Power AC Mode - Available Max. AC Current                                                                                    V-F Rating Chart - 300V Range

        100%                                                                                                                                          350

Current 90%                                                                                                                                           300
(RMS) 75%
                                                                                                                                                      250
                                                                                                                                         Volt (RMS)




                                                                                                                                                      200
                                                                                                                 Full
         50%
                                                                                                                Power
                                                                                                                                                      150


         25%                                                                                                                                          100


                                                                                                                                                       50

                                                                                                                                                        0
         0%          5%                 25%                       50%                       75%              90%       100%                                  16    200   400   500    600         800         1000
                                                                                                                                                                                                         Frequency (Hz)
                                                                                                  Voltage (RMS)




Note:    Specifications are subject to change without notice. Specifications are warranted over an ambient temperature range of 25°± 5° C. Unless otherwise noted, specifications are per phase for a sinewave with a resistive
         load and apply after a 30 minute warm-up period. For three phase configurations, all specifications are for L-N. Phase angle specifications are valid under balanced load conditions only.




                                                                                                                                        www.california-instruments.com
                                                                                                                                            An               Company



  iM Series II - Specifications
 Measurement
Measurements:               Not available. Refer to i Series for AC power source models with measurement functions.
 Storage
Non Volatile Mem. storage: 16 instrument setups
 Waveforms
Waveform Types:              Sine
User defined waveform
                             Not available. See iX Series II datasheet for power sources witharbitrary waveform capabilities
storage:
 System Interface
Inputs:                     Remote shutdown, External Sync, Clock/Lock (option)
Outputs:                    Function Strobe, Clock/Lock (option)
 Protection
Over Load:                   Constant Current or Constant Voltage mode
Over Temperature:            Automatic shutdown
 Remote Control
USB Interface:              USB 1.0. Max baud rate 460800 bps, IEEE-488.2 SCPI Syntax (USB cable not included).
                            9 pin D-shell connector, Handshake: CTS, RTS, Data bits: 7,8, Stop bits: 1, 2, Baud rate: 9600, 19200, 38400, 57600, 115200, IEEE-488.2
RS232C Interface:
                            SCPI Syntax (Supplied with RS232C cable).
 AC Input
                            3001iM: 208-240 ± 10% Vac, (L-N, 1ø), All other models: Standard: 208-240 ± 10% Vac, (L-L, 3ø), Option -400: 400-480 ± 10% Vac, (L-L,
Voltage:
                            3ø) (Input range must be specified when ordering).

                             Model            3001iM        5001iM       10001iM    15001iM        15003iM
Input Line Current (per
                             187-264V         25 A          23 A         46 A       69 A           69 A
phase):
                             360-528V         N/A           12 A         24 A       36 A           36 A

Inrush Current per chassis: < 100 Apk for 100 µs at 208-240 V, < 50 Apk for 100 µs at 400-480 V
Line Frequency:             50-60 Hz ± 10 %
Efficiency:                 75% typical
Power Factor:               0.6 typical
 AC Service
Regulatory:                 IEC61010, EN50081-2, EN50082-2, CE EMC and Safety Mark requirements
RFI Suppression:            CISPR 11, Group1 , Class A
                            AC Input & Output terminal block with cover, 9 pin D-Shell RS232C and USB connector*, Remote voltage sense terminal block, Sys-
Rear Panel Connectors:
                            tem Interface Connector, *RS232 DB9 to DB9 cable supplied
 Physical Dimensions
Dimensions:                 Height: 7" (178 mm), Width: 19" (483 mm), Depth: 24" (610 mm) (depth includes rear panel connectors)
Weight:                     per 5001iM Chassis: Net: 61 lbs / 28 Kg, Shipping: 115 lbs / 52 Kg
Vibration and Shock:        Designed to meet NSTA project 1A transportation levels
Air Intake/Exhaust:         Forced air cooling, side air intake, rear exhaust.
Operating Humidity:         0 to 95 % RAH, non condensing.
Temperature:                Operating: 0 to 40° C, Storage: -20 to +85° C




www.california-instruments.com
                                                                            An                                 Company

   Ordering Information
Available Models:
    Model                          Output Phase                          Max. current per phase                                      Input      Model
                                    Power Output                       Low V range High V range                                     Voltage1       Refer to table shown for model num-
                                       AC                              AC       DC      AC      DC                                                 bers and configurations.
    3001iM                           3 kVA  1                           22      15.6    11       7.8                                208-240V    Supplied with
    5001iM                              5 kVA             1              37            26              18.5           13            208-240V       User Manual, Programming Manual, (all
                                                                                                                                                   on CD ROM), RS232C serial cable.
    5001iM-400                          5 kVA             1              37            26              18.5           13            400-480V
                                                                                                                                                Options
    10001iM                          10 kVA               1              74            52              37             26            208-240V
                                                                                                                                                -400       400-480 Volt Line to Line AC
    10001iM-400                      10 kVA               1              74            52              37             26            400-480V               input.
    15001iM                          15 kVA               1            111             78              55.5           39            208-240V    -EXS       External Sync
                                                                                                                                                -LKM       Clock/Lock Master
    15001iM-400                      15 kVA               1            111             78              55.5           39            400-480V
                                                                                                                                                -LKS       Clock/Lock Auxiliary
    15003iM                          15 kVA               3              37            26              18.5           13            208-240V    -LNS       Internal AC Line Sync.
    15003iM-400                      15 kVA               3              37            26              18.5           13            400-480V    -RMS       Rackmount Slides.
                                                                                                                                                -XLS       External AC Line Sync adaptor.
Note (1): All input voltage specifications are for Line to Line three phase except 3001iM which requires single phase input only.
                                                                                                                                                           (-LNS and XLS are mutually
                                                                                                                                                           exclusive)
     iM Series II Rear Panel                                                                                                                    Cabinets   Multi box iM Series systems can
                                                                                                                                                           be factory installed and wired
                                                                                                                                                           in 19 inch cabinets. Cabinet
                                                                                                                                                           configurations can be ordered
                                                                                                                                                           by preceeding the model num-
                                                                                                                                                           ber with a "C1-C4" prefix. See
                                                                                                                                                           Cabinet data sheet.




   9689CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 ·
       Towne Centre Drive, San Diego, CA 92121-1964 l (858) 677-9040                                                                    D-85716(858) 677-0940 l sales@calinst.com
                                                                                                                                         l FAX: Unterschleißheim
   © Copyright 2007-2008, California Instruments Corp.                                      Specifications subject to change without notice            Printed in the USA        iMSII 09/08
                Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11 · www.compumess.de · www.netzteile.de