A NEW PARADIGM IN THE DESIGN OF A-C TO D-C PROGRAMMABLE POWER SUPPLIES.



   CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
     Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11 · www.compumess.de · www.netzteile.de


                                           AN ISO 9001 COMPANY
TALK . LISTEN.
                                 ETHERNET                 KEPCO'S KLP IS PROGRAMMABLE IN MANY LANGUAGES,
                                                          USING MANY COMMON INTERFACES.
Models with the -1.2K suffix provide a LAN port
which is an LXI-approved Ethernet- based interface        There are two versions of KLP offered, with differing digital
allowing multiple-user access via a standard web          programming options. Models with the suffix -1200 are
browser. The factory default LAN settings on the          equipped with GPIB (IEEE-488.2) and RS-232 digital programming
KLP are DCHP on, AUTOIP on. When the power                ports. Models with the suffix -1.2K are equipped with a LAN
supply is powered up, it will try to find a DCHP          (Ethernet, RJ-45) connector in place of the RS-232. The LAN
server and get an IP address, If a server is not found,
the KLP will use AUTOIP to get an address.                interface is an LXI-approved ethernet-based                    TM
                                                          interface that allows multiple-user access via a
                                                          standard web browser.

                                                          The GPIB port accepts addresses 1 to 31 (factory default is 6). The
                                                          RS-232 operates at baud rates up to 38,400 (default). All digital
                                 IEEE-488                 programming ports provide SELV (Safety Extra Low Voltage)
                                                          isolation for operator and equipment protection. The format is
In all models, the GPIB port accepts a standard           compatible with SCPI, offering programming resolution of
GPIB connector and communicates bi-directionally          0.024% with a readback accuracy of 0.1% of Emax or Ilim.
with a GPIB host computer interface. The GPIB input
supports LabView G which provides a "soft" panel          All KLP models may be controlled by analog signals, a variable
visible on the driving computer. VXI plug&play is         voltage or a variable resistance. These analog inputs are fully
also supported. This also provides a "soft" panel         isolated from the output and the chassis.
display on the host computer. These functions are
described in the KLP Developer's Guide.                   The KLP offers storage
                                                          of user-programmed
                                                          active settings. In ad-
                                                          dition to adding single
                                                          steps, a user may
                                                          add multiple steps
                                 RS-232
                                                          to produce voltage                       Rear view, Ethernet (LAN) port, -1.2K version
Models with the -1200 suffix support RS-232               or current ramps.
operating at baud rates up to 38,400 (default).
                                                          Kepco provides three
The format is compatible with SCPI, offering
programming resolution of 0.024% with a readback          instrument drivers:
accuracy of 0.1% of Emax or Ilim.                         IVI-COM, LabView G
                                                          and VXI plug&play,
                                                          which simplify pro-
                                                          gramming of the KLP
                                                                                                 Rear view, RS-232 port, -1200 version
                                                          power supply via the
                                                          digital interfaces. These drivers and sample programs are supplied
                                 ANALOG I/O               on a CD shipped with each unit and may be downloaded from the
The input defaults are 0 to 10V d-c voltage or
                                                          Kepco website at: www.kepcopower.com/drivers.
0 to 10K ohms resistive. Both voltage setting and
current setting are controllable by these analog
signals. The maximum levels can be set in the
                                                          Call us to     TALK about the Series KLP Power Supplies.
calibration routine to match whatever a user has
available (0-5V, 0-3.3V etc.) Readback is a 0-10V             KEPCO, INC. · 131-38 Sanford Avenue · Flushing, NY 11355 USA
proportional signal. Isolated form-C relay contacts                     Tel: (718) 461-7000 · Fax: (718) 767-1102
provide a composite status flag.                             Email: hq@kepcopower.com · www.kepcopower.com/klp.htm
                                                          Data subject to change without notice.                © 2007 KEPCO, INC.   Litho in USA
                     Using high-frequency switch-mode topology for high efficiency and small size, the KLP provides 1200 watts
                       of well-regulated, controllable d-c power in a 1U (1.75 inch high) by 19 inch rack-mountable package.


KLP REPLACES THE NEED FOR MULTIPLE POWER                                          KEPCO IS NOT JUST AHEAD OF THE CURVE, WE'VE FORMED
SUPPLIES BY EXPANDING THE OPERATING REGION.                                       A WHOLE NEW ONE.
THE BREAKTHROUGH OF A HYPERBOLIC POWER LIMIT                                      The KLP output locus is not limited to the familiar rectangular
DELIVERS A FULL 1200 WATTS OVER AN EXPANDED                                       CV/CC shape used by most laboratory-type power supplies. KLP
OPERATING RANGE, NOT JUST A SINGLE POINT.                                         features a hyperbolic power limit formed by an infinite number
                                                                                  of volt-ampere combinations that remain within the power
             V                                                                    supply's overall 1200 watt power limit. The KLP continuously
                                                                                  calculates what the maximum current can be at a given voltage
        75                                A                  KEPCO KLP'S          setting to stay within its 1200 watt power envelope.
                                                             1200 WATT
                    ADDITIONAL                               EXTENDED             The result is two loci of constant voltage and constant current
                    OPERATING                                MAXIMUM
                      REGION                                 POWER                forming a third locus by intersecting in a constant power
                                                     B       RANGE                hyperbolic curve. This hyperbolic curve opens a much wider
                                                             "A" THRU "C"
                                                                                  operating range of reduced current at higher voltage and
                                                                                  reduced voltage at higher current ­ operating regions that are
                                                                    C             unavailable in conventional power supplies.
VOLTS




        36            CONVENTIONAL
                      POWER SUPPLY'S                                              Because the range of possible outputs from a single KLP model
                        MAXIMUM
                       POWER POINT                                                is so much greater than what is customary, KLP supports the
                                                     ADDITIONAL                   idea of a virtual model ­ a user-defined maximum programmable
                                                     OPERATING
                                                       REGION                     voltage and current profile, within the 1200 watt power limit
                      CONVENTIONAL
                     OPERATING REGION                                             and the KLP's voltage and current maxima. Once established,
                                                                                  the KLP will not accept programmed values outside of these limits
                                                                          I
                                                                                  whether from the front panel in local mode, or from the digital
         0                          16                             33             (GPIB, RS-232, or LAN) ports, or the analog input ports in remote
                                  AMPERES                                         mode. The virtual-model settings are password protected.


    KLP MODEL TABLE

                               RATED VOLTAGE   MAXIMUM CURRENT      MINIMUM PROGRAMMABLE    RATED CURRENT    MAXIMUM VOLTAGE    RIPPLE AND   EFFICIENCY
    MODEL                        RANGE (1)     FOR RATED VOLTAGE           CURRENT            RANGE (1)     FOR RATED CURRENT    NOISE (2)   @115V a-c

    KLP 10-150-1.2K (3)           0-10V         120A@10V                      3.2A            0-150A          8V@150A           75 mV          80%

    KLP 20-120-1.2K (3)           0-20V          60A@20V                      1.6A            0-120A          10V@120A          75 mV          82%

    KLP 36-60-1.2K (3)            0-36V         33.3A@36V                     0.8A             0-60A          20V@60A           125 mV         83%

    KLP      75-33-1.2K (3)       0-75V          16A@75V                      0.4A            0-33.3A        36V@33.3A          125 mV         84%

    KLP      150-16-1.2K (3)     0-150V          8A@150V                      0.2A             0-16A          75V@16A           125 mV         86%

    KLP 300-8-1.2K (3)           0-300V          4A@300V                      0.1A              0-8A          150V@8A           300 mV         87%

    KLP      600-4-1.2K (3)      0-600V          2A@600V                      0.05A             0-4A          300V@4A           400 mV         88%

(1) The maximum current and voltage are constrained by the 1200 watt power limitation.
(2) Bandwidth: 20MHz; low frequency ripple may be higher at loads less than 30 Watts.
(3) Models shown with the suffix -1.2K refer to the LAN (LXI) interface. RS-232 interface                           AN ISO 9001 COMPANY
    models use the suffix -1200. All specifications apply to both types of models.

                          KEPCO, INC. · 131-38 Sanford Avenue · Flushing, NY 11355 USA
                                    Tel: (718) 461-7000 · Fax: (718) 767-1102
                         Email: hq@kepcopower.com · www.kepcopower.com/klp.htm
                                                  KLP INPUT CHARACTERISTICS
                                                      SPECIFICATIONS                           RATING/DESCRIPTION           CONDITION

                                                  a-c                        nominal            100-240V a-c             Single phase
                                                  Voltage
                                                                                range           100-255V a-c             Wide range
                                                  d-c                           range           125-420V d-c            No regulatory
                                                  Voltage                                                              agency approval
                                                  Frequency         nominal range                 50-60 Hz               Single phase
FEATURES
                                                                           maximum                45-440 Hz            Increased leakage
                                                                                                                          above 66 Hz
Switch mode topology for cool,                    Power Factor                 typical               0.99             Meets EN 61000-3-2
efficient operation
                                                  Maximum                   120V a-c               13A rms                Rated load
                                                  Input Current                                                            (1200W)
GPIB and isolated analog programming                                        240V a-c              6.5A rms
standard on all models                            Inrush                    265V a-c                 40A
                                                  Current                                                                    Peak
                                                                            132V a-c                  20A
-1200 models have an RS-232 interface             Input Fusing                                 Circuit Breaker              2-line
                                                  Low a-c Protection                            Self Protected          No fixed limits
-1.2K models replace the RS-232 interface
with an Ethernet (RJ-45) connector                Output Hold Up               typical         10 milliseconds           Ride through
supporting LAN (LXI)                              Leakage        115V a-c, 60 Hz                     5mA
                                                  Current
                                                                 230V a-c, 50 Hz                    10mA
1U panel height at 1200 watts

Front to back air flow allows full power          KLP OUTPUT CHARACTERISTICS
operation without spacers between supplies
                                                          SPECIFICATIONS                       RATING/DESCRIPTION          CONDITION

Seven models:                                     Stabilizer Type                                 CV/CC                Voltage/Current
KLP 10-150-*, KLP 20-120- *, KLP 36-60- *,        Adjustment                 voltage     0-100% of rated voltage         No minimum
KLP 75-33- *, KLP 150-16- *, KLP 300-8- *,        Range                                                                 load required
                                                                             current min-100% of rated current (1)
KLP 600-4- *
                                                  Source Effect              voltage            0.01% Emax                Over full
* -1200 suffix includes RS-232 interface                                     current            0.01% lmax              source range
* -1.2K suffix includes LAN (LXI) interface
                                                  Load Effect                voltage            0.01% Emax              Over full load
                                                                           current(2)           0.02% lmax              current range
Wide-range a-c input, 100-255V a-c with PFC
                                                  Temperature                voltage             0.2%/ºC
                                                  Effect                                                                   0-50ºC
Dimensions: HxWxD                                                            current              0.2%/ºC
1.75" x 19" x 17.5"                               Time Effect                voltage            0.05%/24hr             After 30 minute
44.45 x 482.6 x 443.7 mm                          (drift)
                                                                             current            0.05%/24hr                 warmup
                                                  Error Sensing                             0.25 volts per wire       Above rated output
Weight:
15 lbs., 6.82kg                                   Isolation Voltage                          600V d-c or peak            Either output
                                                                                                                      terminal to ground

                                                  Transient            excursion                1% of Emax             50% load step
                                                  Recovery for                                                         2A/µsec max
FOR FULL SPECS :                                  Load Change
                                                                           recovery               2 msec               Return to 0.1%
                                                                                                                         of setting
www.kepcopower.com/klp.htm                        Turnon/turnoff Overshoot                   Same as load transient response limits
                                                  Overvoltage                voltage         20-120% of Emax           User selectable
                                                  Protection                                                              recovery
                                                  Overcurrent                current          72-120% of Imax          User selectable
                                                  Protection                                                              recovery
              AN ISO 9001 COMPANY
                                                  Overtemperature                                Shutdown              User selectable
                                                  Protection                                                              recovery
                                                  Output Lead Fault                             Shutdown               User selectable
                                                  Protection                                                              recovery
                                                  Parallel Operation                     Active load sharing within     Up to 5 units
       KEPCO, INC. · 131-38 Sanford Avenue                                                     5% of I0 rated           maximum (3)