Hier Klicken für das PDF Dokument!!!

LF100ED Series
Lowest Cost, Dual Output
Ultra-Miniature 1W SMT
DC/DC Converters
                                Electrical Specifications
                                Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
                                 Input
Key Features:
                                 Parameter                                                              Conditions                           Min.       Typ.       Max.          Units
· 1W Output Power
                                                                                                                     3.3 VDC Input            3.0        3.3        3.6
· Ultra-Miniature SMT Case       Input Voltage Range                                                                    5 VDC Input           4.5        5.0        5.5           VDC
· UL Approved (File E245422)                                                                                          12 VDC Input           10.8       12.0       13.2
· Dual Outputs                   Reverse Polarity Input Current                                                                                                     1.0             A
· Low 0.29" Profile              Input Filter                                                                                      Capacitor
· 1,000 VDC Isolation            Output
                                 Parameter                                                              Conditions                           Min.       Typ.       Max.          Units
· >3.5 MHour MTBF
                                 Output Voltage Accuracy                                                                                                ±3.0                       %
· 3.3V, 5V, & 12V Inputs
                                 Output Voltage Balance                                                            Balanced Loads                       ±1.0                       %
· LOWEST COST!
                                 Line Regulation                                                          For Vin Change of 1%                                     ±1.2            %
                                 Load Regulation (Note 1)                                                              See Model Selection Guide
                                 Ripple & Noise (20 MHz) (Note 2)                                                                                        50         75         mV P - P
                                 Temperature Coefficient                                                                                                          ±0.03          %/ºC
                                 Output Short Circuit                                                                      Momentary (0.5 Sec.)
                                 General
                                 Parameter                                                              Conditions                           Min.       Typ.       Max.          Units
                                 Isolation Voltage                                                                       60 Seconds         1,000                                 VDC
                                 Isolation Resistance                                                                        500 VDC        1,000                                 M
                                 Isolation Capacitance                                                                  100 kHz, 1V                      70                        pF
                                 Switching Frequency                                                                                                    100                       kHz
                                 Environmental
                                 Parameter                                                              Conditions                           Min.       Typ.       Max.          Units
                                 Operating Temperature Range                                                                 Ambient          -40       +25        +85             ºC
                                 Storage Temperature Range                                                                                    -55                  +125            ºC
                                 Cooling                                                                                    Free Air Convection
                                 Humidity                                                                   RH, Non-condensing                                      95             %
                                 Physical
                                 Case Size                                                                                 0.60 x 0.29 x 0.24 Inches (15.24 x 7.5 x 6.0 mm)
MicroPower Direct                Case Material                                                                                      Non-Conductive Black Plastic (UL94-V0)
292 Page Street
Suite D                          Weight                                                                                                                                   0.05 Oz (1.5g)
Stoughton, MA 02072              Reliability Specifications
USA                              Parameter                                                              Conditions                           Min.       Typ.       Max.          Units
T: (781) 344-8226                MTBF                                                    MIL HDBK 217F, 25ºC, Gnd Benign                      3.5                              MHours
F: (781) 344-8481                Safety Standards                                                                    UL 1950, EN 60950, IEC 60950
E: sales@micropowerdirect.com    Safety Approvals                                                                       UL, cUL; File No. E245422
W: www.micropowerdirect.com
                                 Absolute Maximum Ratings
                                 Parameter                                                              Conditions                           Min.       Typ.       Max.          Units
                                                                                                                     3.3 VDC Input           -0.7                   7.0
                                 Input Voltage Surge (1 Sec)                                                            5 VDC Input          -0.7                   7.0           VDC
                                                                                                                      12 VDC Input           -0.7                  15.0
                                 Lead Temperature                                               1.5 mm From Case For 10 Sec                                       260.0            ºC
                                 Internal Power Dissipation                                                               All Models                                450           mW
                                      Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.

                                                             CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
                                                             Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
                                                             info@compumess.de · www.compumess.de · www.netzteile.de
Model Selection Guide
                               Input                          Output             Load                                            Fuse Rating
  Model                                                                                                             Efficiency
               Voltage (VDC)           Current (mA)  Voltage Current  Current Regulation                                          Slow-Blow
 Number                                                                                                              (%, Typ)
             Nominal    Range      Full-Load No-Load (VDC) (mA, Max) (mA, Min) (%, Max)                                              (mA)
LF101ED         5      4.5 - 5.5      277        30   ±5.0   ±100.0   ±10.0       12.0                                  72            500
LF102ED         5      4.5 - 5.5      250        30   ±9.0    ±56.0    ±6.0        8.0                                  75            500
LF103ED         5      4.5 - 5.5      256        30  ±12.0    ±42.0    ±5.0        8.5                                  78            500
LF104ED         5      4.5 - 5.5      253        30  ±15.0    ±33.0    ±4.0        7.0                                  79            500
LF111ED        12     10.8 - 13.2     112        15   ±5.0   ±100.0   ±10.0       12.0                                  74            200
LF112ED        12     10.8 - 13.2     110        15   ±9.0    ±56.0    ±6.0        8.0                                  76            200
LF113ED        12     10.8 - 13.2     105        15  ±12.0    ±42.0    ±5.0        8.5                                  78            200
LF114ED        12     10.8 - 13.2     104        15  ±15.0    ±33.0    ±4.0        7.0                                  79            200
LF151ED        3.3    3.0 - 3.6       452        55   ±5.0   ±100.0   ±10.0       12.0                                  67            750
LF152ED        3.3    3.0 - 3.6       445        55  ±12.0    ±42.0    ±5.0        8.5                                  68            750
LF153ED        3.3    3.0 - 3.6       432        55  ±15.0    ±33.0    ±4.0        7.0                                  70            750
Notes:
1. Output load regulation is specified for a load change of 20% to 100%.
                                                                                         Derating Curve
2. When measuring output ripple, it is recommended that an external 0.33 µF ce-
   ramic capacitor be placed from the +Vout pin to the -Vout pin for single output
   units and from each output to common for dual output units.
3. During operation, care must be taken not to exceed the specified input range
   of the unit or to allow the output load to drop below the specified minimum
   (10% of full load). Operating the unit under either of these conditions could
   cause damage to the unit.
4. These converters are specified for operation without external components. How-
   ever, in some applications the addition of input/output capacitors will enhance
   stability and reduce output ripple. Recommended capacitor values are:
                Input                  Output
      Vin                   Vout
              Capacitor               Capacitor
    5 VDC       4.7 µF      5 VDC      4.7 µF
    12 VDC      2.2 µF      9 VDC      2.2 µF
    24 VDC      1.0 µF     12 VDC      1.0 µF
                           15 VDC      0.47 µF        Pin Connections
   For applications requiring very low output noise     Pin   Description        Pin   Description    Recommended Solder Profile
   levels, a simple LC filter should be effective.       1       -Vin         6       NC
5. It is recommended that a fuse be used on the          2       +Vin         7      +Vout
   input of a power supply for protection. See the
                                                         3        NC          8       NC
   Model Selection table above for the correct
   rating.                                               4     Common         9       NC
                                                         5      -Vout        10       NC
Mechanical Dimensions                                             NC = No Connection




                                                                                                                 Board Layout




                                                  Notes:
                                                  · All dimensions are typical in inches (mm)
                                                  · Tolerance x.xx = ±0.01 (±0.25)
                                                  · Pin 1 is marked by a "dot" or indentation on the unit



                         MicroPower Direct
                                            www.micropowerdirect.com GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
                                                        CompuMess Elektronik
                      292 Page Street Ste D Stoughton, MA 02072             ·   Telefon (089) 32 15 01 - 0 · Telefax (089) 32· E-Mail: sales@micropowerdirect.com
                                                                                  TEL: (781) 344-8226 · FAX: (781) 344-8481 15 01 - 11
                                                                                info@compumess.de · www.compumess.de · www.netzteile.de