Open PCB Switching Power
Watt
Supplies 100 Watt Single Outputs
Auto Switching Input LPS-100
High Efficiency Series
Regulated Outputs
3000V Isolation
Single Outputs
Unit measures 2.4"W x 8.7"L x 1.4"H
MODEL SELECTIONS
Output Output Price
Model Number Voltage Amps (MAX) Min Load 1 25
SINGLE OUTPUT
LPS-100-3.3 3.3 VDC 20A 0A $49 $45
LPS-100-5 5.0 VDC 20A 0A $49 $45 Contact
LPS-100-7.5 7.5 VDC 13.3A 0A $49 $45
Factory
LPS-100-12 12VDC 8.4A 0A $49 $45
LPS-100-13.5 13.5VDC 7.5A 0A $49 $45 for
LPS-100-15 15VDC 6.7A 0A $49 $45 Volume
High Volume
LPS-100-24 24VDC 4.2A 0A $49 $45 Pricing
LPS-100-27 27VDC 3.8A 0A $49 $45
LPS-100-48 48VDC 2.1A 0A $49 $45
CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de
Open PCB Switching Power
All specifications are typical at 230VAC input, full load, and 25DegC
Watt
Supplies 100 Watt Single Outputs
unless otherwise noted
SPECIFICATIONS
INPUT SPECIFICATIONS ENVIRONMENTAL SPECIFICATIONS (CONT.)
ENVIRONMENTAL SPECIFICATIONS (CONT.)
Input Voltage Range 88~132/176~264 VAC EMC CISPR22(EN55022),
Auto Switching IEC1000-2,3,4
Input Current 2.3A/115V 1.5A/230V MTBF 122,000 Hrs
Frequency Range: 47-440 Hz
Inrush Current, typ: Cold Start 60A/230V * SPECIFICATIONS
PHYSICAL SPECIFICATIONS
Leakage Current <1mA/240VAC
Size 2.4" x 8.7" x 1.4"
SPECIFICATIONS
OUTPUT SPECIFICATIONS Construction Open Frame
Weight 13 oz, (370g)
Voltage and Current See Selection Chart
Load Regulation (0%-FL) +/- 2% Max of FS, typ MECHANICAL DIMENSIONS
Line Regulation +/- 0.5%, typ
Output V. Tolerance +/- 2-3%, typ
DC Voltage Adjust
3.3V 3-3.6V 15V 13.5-18V
5V 4.5-5.7V 24V 20-26V
7.5V 6-9V 27V 26-32V
12V 10-13.2 48V 41-56V
13.5V 12-15V
Temperature Coefficient +/-0.05%/°C (0-50°C)
Ripple/Noise
3.3, 24, 27, Vout 150mVp-p, typ
48 Vout 200mVp-p, typ
All other O/P's 100mVp-p, typ
Over Voltage Protection *
3.3,5,12,13.5,24 Vout 115%~135%
7.5,27 Vout 125%~145% Pin # Single Output
15,48 Vout 120%~140%
Overload Protection 105~140% Pulse Shtdwn, 1 + Output
Auto Recovery 2 + Output
Setup/Rise/Holdup 3 + Output
230 VAC 800mS/50mS/20mS 4 + Output
5 - Output
115 VAC 1.2S/50mS/20mS
6 - Output
SPECIFICATIONS
GENERAL SPECIFICATIONS 7 - Output
8 - Output
Input-Out Isolation I/P-O/P:3000VAC
I/P-G: 1500VAC DERATING CURVE
OUTPUT DERATING CURVE
O/P: 0.5KVAC
Isolation Resistance
I/P-O/P, I/P-G O/P-G: 500VDC/100M
Efficiency 78%, typ
Switching Frequency 135Khz, (fixed, typical)
Safety
EN60950 TUV File # R 9754834
UL1950 UL File # E183223
ENVIRONMENTAL SPECIFICATIONS
ENVIRONMENTAL SPECIFICATIONS
Oper. Temperature -10~+60°C(See Derate Curve)
Storage Temperature -20 to +85°C *
Relative Humidity 10% to 90%, non-cond *
Vibration 10~500Hz, 2G 10min./1cycle, Astrodyne products are not authorized or warranteed for
PERIOD FOR 60min. use as critical components in life support systems,
EACH AXES equipment used in hazardous environments, nuclear
CompuMess Elektronik GmbH · Lise-Meitner-Str.1 other mission-critical applications.
controls systems, or · 85716 Unterschleissheim
* These are stress ratings. Exposure of the devices to any of these conditions may
Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de
adversely affect long term reliability. Proper operation under conditions other than the
standard operating conditions is neither warranteed nor implied.