Hier Klicken für das PDF Dokument!!!

MEASURINGPAD
                                                                                                                                                                             MEASURING
 SPECIFICATIONS
Scanning, Monitoring, and Recording                                                                      Test /Process Interface                        (continued)
Scan Rate: 10 kHz per analog input; 40 kHz per digital input                                               Thermocouple
16-bit A/D conversion



                                                                                                                                                                                  PAD
                                                                                                              Accepts Types B, E, J, K, N, R, S, and T
Overall Accuracy (All Measurements): ±0.1% of full scale or better                                            Resolution: 0.1 degree
Overrange (All Measurements): 10% of full scale                                                               Input linearization via NIST table
Logging Modes:                                                                                                Input Impedance: 10 M (differential); 1 M (common-mode)
  Manual: A single "snapshot" record taken via touchscreen button                                             Accuracy: ±0.1% of full scale DC ± 0.5° C cold-junction
  Timed: Records taken automatically between specified start and                                              compensation
  stop times; user-specified rate from one second to 24 hours
  Event-Triggered: Records taken while any triggering limit violation
                                                                                                              Connection: Mini jacks                                         A versatile, short-term data acquisition solution
                                                                                                         Digital Inputs (All Pods)
  or digital input occurs; user-specified rate from one millisecond to
  24 hours, or "burst" speed (as fast as possible); overrides timed
                                                                                                           Maximum Frequency: 20 kHz                                                    for maintenance, troubleshooting and
                                                                                                           Minimum Time Interval (for timed inputs): 1 msec
  logging, and may include "pretrigger" data, if desired
User-enabled beeper for setpoint violation alert
                                                                                                           VL: 0 to 0.6 VDC                                                                 energy measurement applications
                                                                                                           VH: 4.5 to 24 VDC
                                                                                                           RIN: 6.0 k, approximate
Test /Process Interface
                                                                                                           Isolation: Optically isolated to 750 VAC RMS, common-mode
Up to four external sensor interface pods per MeasuringPAD
                                                                                                           Protected to ±100 VDC or 120 VAC
unit (ordered separately)
                                                                                                           Software-selectable hysteresis debounce when digital inputs
Four DC-coupled differential analog inputs of the same type per
                                                                                                           are used as logging triggers
pod (see below)
                                                                                                           Frequency and quadrature inputs configurable for limit logic
Two digital inputs per pod (see below)
                                                                                                           Connection: Five-way binding posts
EEPROM per pod, for ID and storage of calibration values
Analog Inputs
  Low Voltage Pod
                                                                                                         General Specifications
     Operating Range (Differential and Common-Mode): ±0 to                                               Dimensions (HWD): 12" x 2.5" x 8" (30 cm x 6.4 cm x 20.3 cm)
     30 VDC or 0 to 24 VAC RMS                                                                           Weight: 4.2 lb. (1.9 kg)
     Resolution: Millivolts                                                                              Operating Temperature: -10° to 50° C (14° to 122° F)
     Input Impedance: 4 M (differential); 1 M (common-mode)                                              Storage Temperature: -40° to 85° C (-40° to 185° F)
     Accuracy: ±0.1% of full scale up to 400 Hz; ±1.0% of full                                           Humidity: 95%, noncondensing
     scale up to 6 kHz                                                                                   System Time Clock: Crystal-controlled; 1-second resolution
     Connection: Five-way binding posts                                                                  Display: Contrast-adjustable 320 x 240 LCD color touchscreen with
  High Voltage Pod                                                                                       audible feedback and programmable backlight timeout; available
     Operating Range (Differential and Common-Mode): ±0 to                                               languages include English, French, Italian, German, Spanish
     600 VDC or 0 to 480 VAC RMS                                                                         Memory Card: Compact flash 32M supplied
     Resolution: Hundredths of a volt                                                                    AC Power Adapter supplied (90-264 VAC, 47-63 Hz)
     Input Impedance: 40 M (differential); 10 M (common-mode)                                            Supporting easel and carry strap supplied
     Accuracy: ±0.1% of full scale up to 400 Hz; ±1.0% of full
     scale up to 6 kHz                                                                                   Optional Accessories
     Connection: Safety banana jacks                                                                     Low Voltage and High Voltage Cable Sets
  Low Current                                                                                            Soft-Sided Carrying Case
     Operating Range (Differential): ±0 to 20 mADC or 0 to 20                                            Field-Replaceable Battery Pack
     mAAC RMS
                                                                                                         External Battery Charger
     Resolution: Microamps
                                                                                                         Weatherproof Container
     Input Impedance: 250  (differential); 1 M (common-mode)
                                                                                                         Reusable Shipping Container
     Accuracy: ±0.1% of full scale up to 400 Hz; ±1.0% of full
                                                                                                         Lockable Portable Case
     scale up to 6 kHz
                                                                                                         Memory Cards (32M, 64M, and 128M)
     Connection: Five-way binding posts
                                                                                                         USB Flash Card Reader


                                  1.800.372.6832                          sales@dranetz-bmi.com
                                  tel 732.287.3680 · fax 732.248.1834 · 1000 New Durham Road · Edison, New Jersey 08818 USA
                                  ©2005 Dranetz-BMI. All rights reserved. Printed in the United States. Specifications are subject to change without notice.
      CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
dranetz-bmi.com
             Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de
For temporary but critical on-site data acquisition, the portable, high-speed MeasuringPADTM offers a convenient, economical alternative
to an elaborate test and measurement installation. This sturdy hand-held instrument can be used in a wide range of manufacturing,
laboratory, plant operations, and quality control applications. Rapidly collecting, monitoring, and displaying multiple sensor inputs, it
is ideal for troubleshooting, maintenance, process tuning, fault recording, trend analysis, and much more. Configured and operated
through an easy-to-use color touchscreen interface, MeasuringPAD continuously scans all active inputs, digitizing with 16-bit A/ D while
checking for limit-violation triggers and refreshing its memory buffer at 10 kHz per input.



Real-Time Data Monitoring
MeasuringPAD provides live readout of up to sixteen differential analog inputs and
up to eight logic-level digital inputs. As numerical measurements are monitored
                                                                                                 M EASURING
for exact conformance to user-entered setpoints, the vivid color-coded status display
                                                  lets you size up your test or process
                                                  at a glance. To ensure true
                                                  "finished-answer" readability, analog
                                                  signals are easily scalable to desired
                                                                                                       PAD
                                                  engineering units.

                                                 Convenient input "pods" allow fast
                                                 and easy hookup of machine- or
                                                 process-dedicated sensors ­ including
                                                 DC/AC Low and High Voltage sources
                                                 (from 100 mV to 300 V), DC/AC
                                                 Low Current sources (4 to 20 mA),
                                                 and most Thermocouple types.
                                                 Digital inputs are standard TTL-level
                                                 signals from switches, contacts,
                                                 encoders, pickups, and other
                                                 frequency-generating devices. They
                                                 may be used to trigger the logging
                                                 of data, to perform programmable                                                                                                                                                                                        Using MeasurePAD's unique
                                                 counting and timing operations,
                                                 and to monitor frequency and                                                                                                                                                                                            touchscreen pages, setting up the
                                                 quadrature. Up to eight internal
                                                                                                                                                                                                                                                                         instrument literally takes seconds. Simple user selections and clear,
cross-channel math calculations can also be set up to display and monitor additional
process variables such as horsepower, efficiency, and corrected flow ­ plus signal                                                                                                                                                                                       intuitive pathing make the setup process both easy to use and easy to
max /min and average values.
                                                                                                                                                                                                                                                                         learn. Once created, multiple test-specific setups can be stored for
High-Speed Data Recording                                                                                                                                                                                                                                                instant reloading.
You can instruct MeasuringPAD to sample scaled measurements at a regular time
interval ­ or, immediately on detection of any specified trigger event, to begin
recording at a special rate that can be up to a microsecond-level "burst" speed.
Instantly stored on a standard CF memory card in a simple and universally compatible
ASCII text format, data records are both time- and trigger-stamped, and may be             Multichannel Data Display
directly imported by all kinds of third-party programs for post-analysis and report        For instant operator interpretation of measurement results, the backlit color LCD furnishes real-time display of measured and calculated values in a number of programmable formats, including
generation, without the need for special drivers or version-dependent operating
                                                  systems. If desired, records of data     · bargraph, for rapid visual comparison of up to sixteen
                                                  values as they existed just prior to a     active parameters
                                                  triggering event can be included in      · trend, for simultaneous, independent timeplotting of up to four
                                                  the stored data file. The touch of a       active parameters. Ideal for comparing energy and process /
                                                  button will display a scrollable           production parameters for energy reduction studies.
                                                  spreadsheet report of all currently
                                                  logged data, including time and          · scope, for live display of up to four active waveform inputs in
                                                  event indication.                          a conventional oscilloscope mode
                                                                                           · discrete Fourier transform (DFT), for harmonic analysis
                                                                                             of a selected analog input.