MPA200L Series
Low Profile 200W
Single Output
Power Factor Corrected Only
6.8 x 3.8 x
AC/DC Power Supplies 1.5 in!!
Key Features: Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
h
· 200W Output Power
Input
· Universal 90-264V AC Input Parameter Conditions Min. Typ. Max. Units
· PFC to EN61000-3-2 "D" Input Voltage Range Universal 90 264 VAC
· UL, cUL, TUV Approvals Input Frequency 47 63 Hz
· CE Certified Input Current, Full Load 100 VAC 4 A
· FCC Class B Emissions Inrush Current, Cold Start 110 VAC 35 A
· 3.3, 5, 12, 24 & 48 V Outputs Leakage Current (Note 1) 240 VAC 1.5 mA
· Peak Power to 600W Power Factor Correction Active, Meets EN61000-3-2 Class D
Input Protection T5A/250V Fuse
Output
Parameter Conditions Typ. Min.
Max. Units
Output Voltage Adjustment By Trim Pot ±5.0 %
Output Regulation (Note 2) ±1.0 %
Hold Time 80% Load 20 mSec
Ripple & Noise (20 MHz) (Note 3) See Model Selection Guide
Overload Protection Hiccup Mode, Auto Recovery 110 140 %
Over Voltage Protection >130% of Rated Output Voltage. Recycle AC Input.
Over Temperature Protection >+85ºC Ambient with Autorecovery
Temperature Coefficient ±0.04 %/ºC
Transient Recovery Time (Note 4) 500 µS
50% Load Change
Transient Response Deviation 5 %
Overshoot/Undershoot At Turn On/Off 5.0 %
Turn On Delay 120 VAC 1 S
Output Short Circuit Continuous With Autorecovery
General
Parameter Conditions Min. Typ. Max. Units
Input - Output 3,000
Isolation Voltage Input - FG (Frame Ground) 1,500 VAC
Primary - Core 1,500
Switching Frequency Fixed 23 kHz
Interface Signals
Power Supply On Green LED (LED1) on the PCB
MicroPower Direct
PG on CN3. Goes TTL high 100 to 500 mS after regulation. Goes low at
292 Page Street Power Good Signal
least 1 mS before the loss of regulation. Will sink 100 mA.
Suite D
Stoughton, MA 02072 Remote Sense RS + and RS- on CN3. Compensates for up to a 0.5V line drop.
USA Remote On/Off REMO on CN3. A TTL low signal inhibits the output
Environmental
T: (781) 344-8226 Parameter Conditions Min. Typ. Max. Units
F: (781) 344-8481 Operating Temperature Range Ambient 0 +25 +50 ºC
E: sales@micropowerdirect.com Output Derating 2.5%/ ºC from +50 ºC to + 70 ºC
W: www.micropowerdirect.com Storage Temperature Range -20 +85 ºC
Cooling See Model Selection Guide
Operating Humidity RH, Non-condensing 90 %
Reliability Specifications
Parameter Conditions Min. Typ. Max. Units
MTBF MIL HDBK 217F, 30ºC, Gnd Benign 100 kHours
Safety Standards UL 60950; CSA C22.2 No. 60950; TUV EN60950; CB Report (IEC 60950)
EMI Compliance Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,3
EMS Immunity Compliance EN6100-4-2,3,4,5,6,8,11; EN55024,; CE Marked (LVD)
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Model Selection Guide
Output Voltage Output Current (Notes 6, 7, 8) Input Connector CN1:
Model Ripple & Efficiency U-Chassis (U,C)
Factory With Mating Molex Part No. 09-91-0500 (5 pin, 3 used)
Number Range (Note 5) ( U" units) Max.
" Min Noise (Note 7)
PreSet 17 CFM or Howder Terminal Block No. FTB-702-3P (3-pin)
MPA200Lx-03z 3.3 VDC 3.0 - 4.0 VDC 22.00A 0.0A 30.00A 50 mV p-p 70% or equivalent.
MPA200Lx-05z 5 VDC 5.0 - 6.0 VDC 22.00A 0.0A 40.00A 50 mV p-p 75% Output Connector CN2:
Mating Molex Part No. 09-91-1200 (12 pin) or Howder
MPA200Lx-12z 12 VDC 12.0 - 18.0 VDC 12.50A 0.0A 16.66A 1% p-p 80% Terminal Block No. HD-301-4P (4-pin) or equivalent.
MPA200Lx-24z 24 VDC 24.0 - 36.0 VDC 6.25A 0.0A 8.33A 1% p-p 83% Output Pin Assignment:
MPA200Lx-48z 48 VDC 36.0 - 56.0 VDC 3.12A 0.0A 4.16A 1% p-p 83%
Howder Molex
Notes: 5. The full output range (see table above) is covered in the safety agency certification.
1. Models are available with leakage current specified as low as 750 µA. Standard models are factory set to the "Preset" voltage. This may be set to other levels Pins 1 ~ 2: V+ Pins 1 ~ 6: V+
Contact the factory for details. within the range without affecting the agency certification. Contact the factory for Pins 3 ~ 4: V- Pins 7 ~ 12: V-
2. Output regulation includes line & load. details.
3. Ripple & noise is measured from 10 Hz to 20 MHz. Measurement 6. A minimum 1% load is required to maintain load regulation and ripple specifications. Logic Signal Connector CN3:
connection to the unit is made with a 0.1 µF ceramic capacitor & a 22 7. Output current is given for the factory preset voltage. For more information, contact the Mating JST XHP-6 or equivalent (CHYAO SHIUNN
µF electrolytic capacitor connected in parallel. factory.
4. Transient recovery is measured to within a 1% error band for a load 8. Units will provide peak power of 600W for 500 µS. For units capable of longer dura- JS-2001-06).
step change of 50% to 100%. tions, contact the factory. Fan driver connector (FAN):
12 VDC / 500 mA is available to drive an external fan.
Mating JST XHP-2 or equivalent (CHYAO SHIUNN
JS-2001-02).
Mechanical Dimensions: U-Chassis (U Suffix)
U-Chassis Cover (C Suffix)
MicroPower Direct
www.micropowerdirect.com GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
CompuMess Elektronik
292 Page Street Ste D Stoughton, MA 02072 · Telefon (089) 32 15(781) 0 · Telefax (089) 32 15 01 - 11
TEL: (781) 344-8226 · FAX: 01 - 344-8481 · E-Mail: sales@micropowerdirect.com