MPA800R Series
Industrial 800W
Single Output
Power Factor Corrected NEW
Industrial
AC/DC Power Supplies Power!!
Key Features: Electrical Specifications
Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
· 800W Output Power
Input
· 180-264V AC Input Parameter Conditions Min. Typ. Max. Units
· PFC to EN61000-3-2 "D" Input Voltage Range 180 264 VAC
· UL, cUL, TUV Approvals Input Frequency 47 63 Hz
· CE Certified Input Current, Full Load 200 - 240 VAC 6 A
· FCC Class B Emissions Inrush Current, Cold Start 220 VAC 35 A
· 12 - 56 V Output Voltages Leakage Current (Note 1) 240 VAC 1.5 mA
Power Factor Correction Active, Meets EN61000-3-2 Class D
· N+1 Current Share Option
Input Protection T10A/250V Fuse
· Three Mechanical Options
Output
Parameter Conditions Typ. Min.
Max. Units
Output Voltage Adjustment By Trim Pot ±5.0 %
Output Regulation (Note 2) ±1.0 %
Hold Time 220 VAC, 80% Load 20 mSec
Ripple & Noise (20 MHz) (Note 3) See Model Selection Guide
Overload Protection Power Limit 110 140 %
Over Voltage Protection >130% of Rated Output Voltage. Recycle AC Input.
Over Temperature Protection >+85ºC Ambient with Autorecovery
Temperature Coefficient ±0.04 %/ºC
Transient Recovery Time (Note 4) 2.5 mS
50% Load Change
Transient Response Deviation 5 %
Overshoot/Undershoot At Turn On/Off 5.0 %
Turn On Delay 220 VAC 1 S
Output Short Circuit Continuous With Autorecovery
General
Parameter Conditions Min. Typ. Max. Units
Input - Output 3,000
Isolation Voltage Input - FG (Frame Ground) 1,500 VAC
Primary - Core 1,500
Switching Frequency Fixed 23 kHz
Interface Signals
Power Supply On Green LED (LED1) on the PCB
PG on CN3. Goes TTL high 100 to 500 mS after regulation. Goes low at
Power Good Signal
least 1 mS before the loss of regulation. Will sink 100 mA.
MicroPower Direct CSH on CN3. Single wired, forced current sharing option. Up to four
292 Page Street Current Sharing
units may be connected in parallel within 10% accuracy at full load.
Suite D CMN on CN3. A 0.5V to 3.0V output that represents 0% to 100% of the
Stoughton, MA 02072 Current Monitor
unit output current
USA RS + and RS- on CN3. Compensates for up to a 0.5V line drop. (not on
Remote Sense
models with current share option)
T: (781) 344-8226 Remote On/Off RSW on CN3. A TTL low signal inhibits the output
F: (781) 344-8481 Environmental
E: sales@micropowerdirect.com Parameter Conditions Min. Typ. Max. Units
W: www.micropowerdirect.com Operating Temperature Range Ambient 0 +25 +50 ºC
Output Derating 2.5%/ ºC from +50 ºC to + 70 ºC
Storage Temperature Range -20 +85 ºC
Cooling See Model Selection Guide
Operating Humidity RH, Non-condensing 90 %
Reliability Specifications
Parameter Conditions Min. Typ. Max. Units
MTBF MIL HDBK 217F, 30ºC, Gnd Benign 150 kHours
Safety Standards UL 60950; CSA C22.2 No. 60950; TUV EN60950; CB Report (IEC 60950)
EMI Compliance Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,3
EMS Immunity Compliance EN6100-4-2,3,4,5,6,8,11; EN55024,; CE Marked (LVD)
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
Model Selection Guide
Output Voltage Output Current (Notes 6, 7, 8) Input Connector CN1:
Model Ripple & Efficiency U-Chassis (U,C)
Factory ( U" units) Max.
" "F" Units Howder Terminal Block No. HD-121-3P (3-pin) or
Number Range (Note 5) Min Noise (Note 7)
PreSet with 30 CFM Int. Fan Mating Molex Part No. 09-91-0700 (7 pin, 5 used)
MPA800Rx-12zz 12 VDC 12.0 - 15.0 VDC 62.50A 0.0A 62.50A 1% p-p 80% or equivalent.
MPA800Rx-18zz 18 VDC 16.0 - 21.0 VDC 50.00A 0.0A 50.00A 1% p-p 83% Enclosed with Fan (F)
Dinkle Terminal Block No. DT-35-A02W-3 (3-pin) or
MPA800Rx-24zz 24 VDC 22.0 - 30.0 VDC 36.36A 0.0A 36.36A 1% p-p 83% IEC 320 or equivalent snap-in mounting type.
MPA800Rx-36zz 36 VDC 31.0 - 47.0 VDC 25.80A 0.0A 25.80A 1% p-p 83% Output Connector CN2:
MPA800Rx-48zz 48 VDC 48.0 - 56.0 VDC 16.66A 0.0A 16.66A 1% p-p 83% Howder Terminal Block No. HD-121-8P (8-pin) or
Mating Molex Part No. 09-91-2000 (20 pin) or
Notes: 5. The full output range (see table above) is covered in the safety agency certification. Stan- equivalent.
1. Models are available with leakage current specified as low as 750 µA. dard models are factory set to the "Preset" voltage. This may be set to other levels within
Contact the factory for details. the range without affecting the agency certification. Contact the factory for details. Output Pin Assignment:
2. Output regulation includes line & load. 6. A minimum load of 1% is required to maintain load regulation and ripple specifications. Howder Molex
3. Ripple & noise is measured from 10 Hz to 20 MHz. Measurement 7. Output current is given for the factory preset voltage. With the exception of the "12"
connection to the unit is made with a 0.1 µF ceramic capacitor & a 22 (750W) output model, the maximum continuous output power level is 800W with 30 Pins 1 ~ 4: V+ Pins 1 ~ 10: V+
µF electrolytic capacitor connected in parallel. CFM. For more information, contact the factory. Pins 5 ~ 8: V- Pins 11 ~ 20: V-
4. Transient recovery is measured to within a 1% error band for a load 8. Units will provide peak power of 900W for 500 µS. For units capable of longer durations,
step change of 50% to 100%. contact the factory.
Logic Signal Connector CN3:
Mating JST XHP-7 or equivalent (CHYAO
SHIUNN JS-2001-07).
Mechanical Dimensions: U-Chassis (U Suffix) Fan driver connector (FAN):
12 VDC / 500 mA is available to drive an
external fan. Mating JST XHP-2 or equiv-
alent (CHYAO SHIUNN JS-2001-02).
Enclosure With Fan (F Suffix) U-Chassis Cover (C Suffix)
MicroPower Direct
www.micropowerdirect.com GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
CompuMess Elektronik
292 Page Street Ste D Stoughton, MA 02072 · Telefon
TEL: (781) 344-8226 FAX: 01 - 344-8481
(089) 32 15 (781)0 · Telefax (089) 32 15 01 - 11
· · E-Mail: sales@micropowerdirect.com
info@compumess.de · www.compumess.de · www.netzteile.de