MPM-30IS Series
B
Board Mount, 30W
dM t
Single, Dual & Triple Out
AC/DC Power Supplies
Key Features: Electrical Specifications
Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
· 30W Output Power
Input
· Universal 85-265 VAC Input
Parameter Conditions Min. Typ. Max. Units
· EN 60950 Approved Input Voltage Range 85 265 VAC
· Meets IEC Safety Class II Input Frequency 47 440 Hz
· Industry Standard Pin-Out Input Current See Model Selection Guide
· Single, Dual & Triple Outputs 115 VAC 20.0
Inrush Current A Pk
230 VAC 40.0
· Meets EN55022 B
EMI Meets CISPR Pub. 22/FCC Class B
· >250 kHour MTBF 115 VAC 0.1
Safety Ground Leakage Current mA
Chassis Mount Models 230 VAC 0.3
& DIN Rail Mount Output
Option Available! Parameter Conditions Min. Typ. Max. Units
Output Voltage See Model Selection Guide
Output Current See Model Selection Guide
Output Voltage Accuracy, Note 1 ±1.0 ±2.0 %
Line Regulation VIN = Min to Max ±0.2 ±1.0 %
Load Regulation, Single Output IO = Min to Max ±0.5 ±1.0 %
Load Regulation, Dual Output IO = Min to Max ±2.5 ±5.0 %
Load Regulation, Triple Output - Primary IO = Min to Max ±2.5 ±5.0 %
Load Regulation, Triple Output - Aux. IO = Min to Max ±4.0 %
3.3 & 5.0 VDC Output 1.5 1.8
Ripple & Noise (20 MHz) %VP-P of VO
All Other Outputs 1.0 1.3
Hold-Up Time 115 VAC, 60 Hz 20 mSec
Temperature Coefficient ±0.02 %/°C
Over Voltage Protection Zener Diode Clamp 120 % of VO
Short Circuit Protection, Note 4 Continuous (Autorecovery)
Overload Protection, Note 5 Typ. 120% to 180% of Output Power
General
Parameter Conditions Min. Typ. Max. Units
Isolation Voltage Input to Output 3,000 VAC
Isolation Test Voltage Input to Output, Flash Tested For 60S 4,700 VAC
Isolation Resistance 500 VDC 100 M
EMI/RFI Conducted EN 55022 Level B
Electrostatic Discharge (ESD) IEC/EN 61000-4-2 Level B
MicroPower Direct EMC Compliance
RF Field Susceptibility IEC/EN61000-4-3
292 Page Street Electrical Fast Transients/Bursts On Mains IEC/EN 61000-4-4 Level 3 2 kV
Suite D Surge IEC/EN 61000-4-5 Level 3 1kV/2 kV
Stoughton, MA 02072 Switching Frequency 100 kHz
USA Environmental
Parameter Conditions Min. Typ. Max. Units
T: (781) 344-8226 Operating Temperature Range Ambient-25 +25 +71 °C
F: (781) 344-8481 Storage Temperature Range -40 +85 °C
E: sales@micropowerdirect.com Cooling Free Air Convection (See Derating Curve)
W: www.micropowerdirect.com Humidity RH, Non-condensing 95 %
Physical
Case Size 3.50 x 2.50 x 0.85 Inches (88.9 x 63.5 x 21.5 mm)
Case Material Non-Conductive Plastic& Fiberglass (UL94-V0)
Weight 6.23 Oz (177g)
Reliability Specifications
Parameter Conditions Min. Typ. Max. Units
MTBF MIL HDBK 217F, 25°C, Gnd Benign 250 kHours
Safety Standards IEN 60950, IEC 60950
Safety Approvals IEN 60950, IEC 60950
Safety Class IEC 61140 Class II
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Model Selection Guide
Input Output 1 (Vout 1) Output 2 (Vout 2) Output 3 (Vout 3)
Capacitive
Model Current (A) Current (A) Current (A) Current (A) Efficiency
Voltage Voltage Voltage Load
Number (%, Typ)
115 VAC 230 VAC (VDC) Max. Min. (VDC) Max. Min. (VDC) Max. Min. (µF, Max)
MPM-30S-05IS 0.557 0.14 5.0 6.000 0.600 8,000 78
MPM-30S-12IS 0.543 0.14 12.0 2.500 0.250 3,900 80
MPM-30S-15IS 0.543 0.14 15.0 2.000 0.200 3,900 80
MPM-30S-24IS 0.543 0.14 24.0 1.250 0.125 1,500 80
MPM-30S-48IS 0.543 0.14 48.0 0.625 0.063 1,000 80
MPM-30D-12IS 0.565 0.14 +12.0 +1.300 +0.130 -12.0 -1.300 -0.130 ±1,500 80
MPM-30D-15IS 0.543 0.14 +15.0 +1.000 +0.100 -15.0 -1.000 -0.100 ±1,500 80
MPM-30T-0512IS 0.572 0.14 5.0 3.000 +0.600 +12.0 +0.600 +0.120 -12.0 -0.600 -0.120 See Note 6 76
MPM-30T-0512ISA 0.572 0.14 5.0 3.000 +0.600 +12.0 +1.000 +0.200 -12.0 -0.250 -0.050 See Note 6 76
MPM-30T-0515IS 0.572 5.0 3.000 +0.300 +15.0 +0.500 +0.050 -15.0 -0.500 -0.050 See Note 6 76
MPM-30T-5312IS 0.588 5.0 4.500 +0.900 +3.3 +1.000 +0.220 +12.0 +0.250 +0.050 See Note 6 71
MPM-30T-3512IS 0.483 3.3 4.000 +0.800 +5.0 +1.500 +0.300 +12.0 +0.250 +0.050 See Note 6 71
Other output combinations are available Derating Curve
CompuMess Elektronik GmbHthe factory for·details Unterschleißheim
Contact · Lise-Meitner-Str. 1 D-85716 at:
sales@micropowerdirect.com
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11 · www.compumess.de · www.netzteile.de
Notes:
1. For triple output models, the output voltage accuracy of the
auxilliary outputs is typically ±4%.
2. Load regulation is measured for an output change of 0% to
100% at nominal input line. For multiple output models, the
loads are balanced.
3. Operation at no-load will not damage these units. However,
they may not meet all specifications.
4. Output short circuit protection is provided by a "hiccup mode"
circuit. The unit recovers automatically when the fault condition
is removed.
5. Output overload protection is provided by a fold back current
limiting circuit.
6. For triple output models, the maximum capacitive load for 5
VDC and 3.3VDC outputs is 2,200 µF. For all other outputs it is
±1,500 µF.
7. The MPM-30IS series includes a built-in 3.5A/250 VAC fuse. It
is recommended that an external 1.5A slow blow fuse also be
used on the input for protection.
Mechanical Dimensions
Pin Connections
Pin Single Dual Triple
1 AC-Neutral
2 AC-Line
3 +Vo +Vo +Vo 2
4 NP NP +Vo 1
5 -Vo Common Common 2/3
6 NP NP -Vo 1
7 NP -Vo +Vo 3
NC = No Connection
MicroPower Direct
Notes:
· All dimensio are typical in inches (mm)
dimensions
· Tolerance x. = ±0.01 (±0.25)
x.xx
www.micropowerdirect.com GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
CompuMess Elektronik
292 Page Street Ste D Stoughton, MA 02072 · Telefon (089) 32 15 01 - 0 · Telefax (089) 32 · E-Mail: sales@micropowerdirect.com
TEL: (781) 344-8226 · FAX: (781) 344-8481 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de