Specifications typical @ +25°C, 230 VAC input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice.
Key Features: Input
· 15W Output Power Parameter Conditions Min. Typ. Max. Units
· Universal 85-264 VAC Input 85 264 VAC
Input Voltage Range
120 370 VDC
· EN 60950 Compliant
Input Frequency 47 63 Hz
· Single, Dual & Triple Outputs Input Current See Model Selection Guide
· Meets EN55022 B 115 VAC 10.0
Inrush Current A Pk
230 VAC 20.0
· >200 kHour MTBF EMI Meets CISPR Pub. 22/FCC Class B
· Compact PC Mount Case 115 VAC 0.1
Safety Ground Leakage Current mA
230 VAC 0.3
Output
Parameter Conditions Min. Typ. Max. Units
Output Voltage See Model Selection Guide
Output Current See Model Selection Guide
Output Voltage Accuracy ±2.0 %
Line Regulation ±0.5
Load Regulation See Model Selection Guide
Ripple & Noise (20 MHz) 50 mV Pk - Pk
115 VAC 20
Hold-Up Time mSec
230 VAC 80
RoHS Compliant Temperature Coefficient ±0.02 %/°C
Short Circuit Protection Continuous (Autorecovery)
Overload Protection Typ. 110% of Output Power
General
Parameter Conditions Min. Typ. Max. Units
Input to Output 3,000
Isolation Voltage Input to Ground 1,500 VAC
Output to Ground 500
EMI/RFI Conducted EN 55022 Level B
Electrostatic Discharge (ESD) IEC/EN 61000-4-2 Level 3
RF Field Susceptibility IEC/EN61000-4-3
EMC Compliance
Electrical Fast Transients/Bursts On Mains IEC/EN 61000-4-4 Level 3 2 kV
Surge IEC/EN 61000-4-5 Level 3 1kV/2 kV
MicroPower Direct Switching Frequency 150 kHz
292 Page Street Environmental
Suite D Parameter Conditions Min. Max. Typ. Units
Stoughton, MA 02072 Ambient -20 +70 +25 °C
USA Operating Temperature Range
Case +90 °C
Storage Temperature Range -25 +105 °C
T: (781) 344-8226
Cooling Free Air Convection (See Derating Curve)
F: (781) 344-8481
E: sales@micropowerdirect.com Humidity RH, Non-condensing 85 %
W: www.micropowerdirect.com Physical
Case Size 2.44 x 1.77 x 0.88 Inches (62.0 x 45.0 x 22.5 mm)
Case Material Non-Conductive Black Plastic (UL94-V0)
Weight 5.11 Oz (145g)
Reliability Specifications
Parameter Conditions Min. Typ. Max. Units
MTBF MIL HDBK 217F, 25°C, Gnd Benign 200 kHours
Safety Standards IEN 60950, IEC 60950
Safety Approvals (Pending) IEN 60950, IEC 60950
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Model Selection Guide
Input Output 1 (Vout 1) Output 2 (Vout 2) Output 3 (Vout 3)
Model Current (A) Current (A) Over Volt. Current (A) Over Volt. Current (A) Efficiency
Number Voltage Voltage Voltage (%, Typ)
(VDC)
Load Protection (VDC) Load Protection (VDC) Load
115 VAC 230 VAC Typ. (VDC)
Typ. (VDC)
Typ.
Reg. Reg. Reg.
MPM-15S-03 0.25 0.14 3.3 3.000 ±1.0% 6.5 80
MPM-15S-05 0.25 0.14 5.0 2.800 ±1.0% 6.5 80
MPM-15S-12 0.25 0.14 12.0 1.250 ±1.0% 20.0 80
MPM-15S-15 0.25 0.14 15.0 1.000 ±1.0% 20.0 80
MPM-15S-24 0.25 0.14 24.0 0.625 ±1.0% 30.0 80
MPM-15S-48 0.25 0.14 48.0 0.320 ±1.0% 30.0 80
MPM-15D-05 0.25 0.14 +5.0 +1.50 ±2.0% 6.5 -5.0 -1.50 ±2.0% 6.5 80
MPM-15D-12 0.25 0.14 +12.0 +0.65 ±2.0% 20.0 -12.0 -0.65 ±2.0% 20.0 80
MPM-15D-15 0.25 0.14 +15.0 +0.50 ±2.0% 20.0 -15.0 -0.50 ±2.0% 20.0 80
MPM-15T-0505 0.25 0.14 5.0 2.60 ±3.0% 6.5 +5.0 +0.20 ±5.0% -5.0 -0.20 ±5.0% 80
MPM-15T-0512 0.25 0.14 5.0 2.00 ±3.0% 6.5 +12.0 +0.20 ±5.0% -12.0 -0.20 ±5.0% 80
MPM-15T-0515 0.25 0.14 5.0 1.80 ±3.0% 6.5 +15.0 +0.20 ±5.0% -15.0 -0.20 ±5.0% 80
MPM-15T-0524 0.25 0.14 5.0 2.00 ±3.0% 6.5 +24.0 +0.10 ±5.0% -24.0 -0.10 ±5.0% 80
Notes:
1. Load regulation is measured for an output change of 10% to 90% at nominal input Typical Connection
line. For multiple output models, the loads are balanced.
2. The MPM-15 series is specified for operation over the wide operating temperature
range of -20°C to +55°C without derating. For operation over +55°C, derate the
power linearly by 3.75%/°C from +55°C to +70°C.
3. It is recommended that a fuse be used on the input of a power supply for protection.
For the MPM-15 series, a 2A/250 VAC slow blow should be used.
Mechanical Dimensions
Notes:
· All dimensions are typical in inches (mm)
· Tolerance x.xx = ±0.01 (±0.25)
Pin Connections
Pin Single Dual Triple
Typical Component Values
Vout C1, C3, C5 C2, C4, C6 Fuse TVS
1 AC-Ground AC-Ground AC-Ground
3.3 330 ~ 1,000 µF/16V P6KE6.8A
2 AC-Neutral AC-Neutral AC-Neutral
5.0 330 ~ 1,000 µF/16V P6KE6.8A
3 AC-Line AC-Line AC-Line 220 µF/25V
2A/
12.0 0.1 µF/50V P6KE16A
4 -Vo 1 -Vo 2 -Vo 1 250 VAC
15.0 220 µF/25V Ceramic P6KE20A
5 No Pin No Pin +Vo 1 Slow Blow
24.0 120 µF/35V P6KE33A
6 No Pin Common -Vo 2 48.0 68 µF/63V P6KE62A
7 No Pin No Pin Common Notes:
8 +Vo 1 +Vo 1 +Vo 2 1. C1, C3 and C5 are high frequency, low resistance electrolytic capacitors.
Refer to the suppliers specifications for capacitance/current ratings.
2. Voltage derating on all capacitors should be
MicroPower Direct 80% or higher.
3. C2, C4 and C6 eliminate high frequency noise.
4. The TVS is recommended to protect load
www.micropowerdirect.com circuitry in the event of a module failure.
292 Page Street Ste D Stoughton, MA 02072 · CompuMess ElektronikFAX: (781)·344-8481 · E-Mail: sales@micropowerdirect.com
TEL: (781) 344-8226 · GmbH Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de