MEAN WELL PPQ-1003
SWITCHING POWER SUPPLY SERIES
ISO-9001 CERTIFIED MANUFACTURER
.LOW COST, HIGH RELIABILITY .COMPACT SIZE, LIGHT WEIGHT
.105ºC OUTPUT CAPACITOR .100% FULL LOAD BURN-IN TEST
.INTERNATIONAL AC INPUT RANGE .BUILT IN EMI FILTER, LOW RIPPLE NOISE
.HIGH EFFICIENCY, LOW WORKING TEMPERATURE
.SOFT-START CIRCUIT, LIMITING AC SURGE CURRENT
.SHORT CIRCUIT, OVERLOAD, OVER VOLTAGE PROTECTED
MODEL PPQ-1003A PPQ-1003B
SPECIFICATION CH1 CH2 CH3 CH4 CH1 CH2 CH3 CH4
DC OUTPUT VOLTAGE 3.3V 5V 12V -5V 3.3V 5V 12V -12V
OUTPUT V. TOLERANCE ±3% ±3% ±6% ±6% ±3% ±3% ±6% ±6%
OUTPUT RATED CURRENT 10A 10A 2A 0.3A 10A 10A 2A 0.3A
OUTPUT CURRENT RANGE 0-15A 2-15A 0.2-3A 0-1A 0-15A 2-15A 0.2-3A 0-1A
RIPPLE & NOISE(Vp-p) 100m 100m 150m 100m 100m 100m 150m 120m
LINE REGULATION ±1% ±1% ±2% ±1% ±1% ±1% ±2% ±1%
LOAD REGULATION ±2% ±2% ±6% ±1% ±2% ±2% ±6% ±1%
DC OUTPUT POWER 108.5W 110.6W
EFFICIENCY 72%
DC VOLTAGE ADJ. CH1,2:+10%,-5%
INPUT VOLTAGE RANGE 90~264VAC 47~63Hz; 127~370VDC
AC CURRENT 1.65A/115V 0.85A/230V
INRUSH CURRENT COLD START 40A
LEAKAGE CURRENT <1mA/240VAC
OVERLOAD PROTECTION 105%~135% RESET:AUTO RECOVERY
OVER VOLTAGE PROTECTION CH1:3.6~4.3V, CH2:5.75~6.75V
OVER TEMP. PROTECTION ----------
TEMP. COEFFICIENT ±0.03% / ºC (0~50 ºC)
SETUP, RISE, HOLD UP TIME 800ms, 50ms, 16ms
POWER FACTOR PF>0.95/230VAC, PF>0.98/115VAC
VIBRATION 10~500Hz, 2G 10min./1cycle, PERIOD FOR 60min. EACH AXES
WITHSTAND VOLTAGE I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:500VDC / 100M Ohms
WORKING TEMP., HUMIDITY -10 ºC~+60 ºC (REFER TO OUTPUT DERATING CURVE), 20%~90% RH @ @
STORAGE TEMP., HUMIDITY -20 ºC~+85 ºC, 10%~95% RH
DIMENSION 7"*4.25"*1.6" (177.8 *107.95*40.64mm)
WEIGHT 0.5Kgs
SAFETY STANDARDS MEET UL1950, TUV EN60950
EMC STANDARDS MEET CISPR22 (EN55022) CLASS B
NOTE : 1.ALL PARAMETERS ARE SPECIFIED AT 230VAC INPUT, RATED LOAD, 25ºC 70% RH. AMBIENT.
2.TOLERANCE GINCLUDE SET UP TOLERANCE, LINE REGULATION, LOAD REGULATION.
3.RIPPLE & NOISE ARE MEASURED AT 20MHz BY USING A 12" TWISTED PAIR TERMINATED WITH A 0.1uF & 47uF CAPACITOR.
4.LINE REGULATION IS MEASURED FROM LOW LINE TO HIGH LINE AT RATED LOAD.
5.LOAD REGULATION IS MEASURED FROM 20% TO 100% RATED LOAD, AND OTHER OUTPUT AT 60% RATED LOAD.
6.EACH OUTPUT PROVIDE UP TO MAXIMUM CURRENT, BUT TOTAL LOAD CAN NOT EXCEED MAX. OUTPUT POWER. 2000-11-02