Hier Klicken für das PDF Dokument!!!

    SpikeSafe SS200 Precision Pulsed Current Source

             High Performance DC and Pulsed
             · Precise Current Regulation - 0.1%
             · 1 ­ 8 channel configurations
             · Per channel
               - Constant Current to 10A
               - Pulsed Current to 10A/10uS ­ 1S
               - 200V compliance voltage
             · Series drive reduces energy cost/DUT
               ­ up to 62%
             · SpikeSafeTM protects DUTs                                  SpikeSafe 200 8 channel
                                                                           for up to 320 5V DUTS

                                                                                          Copyright 2009, Vektrex, Version 2.2 7/7/2009



 Overview ­ Industry Standard Current Source              Efficient Design Cuts Electricity Use 62%
 For applications that benefit from precisely regulated   In a typical high power burn-in application, the
 current and voltage, the industry standard SpikeSafe     lifetime cost of electricity used often exceeds the
 200 provides single or multiple drive channels at        cost of the equipment itself. The SS200's efficient
 voltages to 200V and currents from 0 to 10A. Flexible    digital power conversion technology wastes little
 operating modes support reliability protocols            power, reducing costs by 62% compared with
 including: DC, pulsed drive, thermal synchronization,    traditional sources.
 long duration flash tests, and user programmable
 waveforms. Precise current regulation meets LM-80        User configurable load tuning capability
 electronic requirements.                                 Programmable load tuning capability adjusts
                                                          internal drive circuitry to maintain pulse fidelity and
 SpikeSafe Protects Devices and Data                      fast transition times to accommodate a variety of
 Load protection algorithms continuously monitor drive    load conditions. Compensation settings include
 voltage and current for anomalies. If an anomaly is      tuning for cable length, load impedance, and rise
 detected, drive is terminated. This shutdown             time. User configurable load protection algorithms
 preserves the individual device for failure analysis,    protect devices.
 and it ensures other devices in the circuit are not
 damaged, ultimately improving overall reliability.
                                                          Applications:
 Modular to Fit Small or Large Applications                     LEDs, Laser Diodes, Solar Cells, Arrays
 The modular SS200 packaging may be configured to
                                                                Reliability test
 support your application. Packaging options include
                                                                Stress Screening
    · 2U bench top / rack chassis; 1-8 channels
    · 9U air-cooled rack crate; 1 ­ 64 channels                 Burn-in and Production Test
    · 19" air-cooled rack; 1 ­ 256 channels                     LM-80 Energy Star compliance
    · OEM to your needs                                         Characterization
 Each channel can power up to 40 series-connected               Tj, Thermal Resistance Measurement
 5V Devices Under Test (DUTs) for a total capacity of
 10,240 DUTs per system.



© Vektrex 2009                                              For more information see www.vektrex.com or call 858-558-8282
 SS200 Precision Pulsed Current Source
 Series Drive Capability Reduces Cost/DUT
 With 200V compliance, each SpikeSafe 200 channel
 can easily drive series circuits with dozens of devices
 under test (DUTs). SpikeSafe load protection assures
 remaining devices are protected even if one fails.
 Optional shunting hardware can automatically bypass
 the failed DUTs allowing the remainder to continue
 operating without user intervention.

 Flexible Power Choices
 In the 2U configuration, the SS200 can be powered
 from the AC mains. For larger applications such as
 volume LED burn-in, the SS200 uses bulk DC power
 provided by an external AC-DC supply. This flexibility
 simplifies facility wiring and reduces overall system
 cost.
                                                             LEDs In Series-Driven Reliability Test

 Simplified Output Cabling
 The SS200 was developed specifically to support DC and pulsed operation in demanding burn-in and life
 test situations in which the device under test is mounted in an external chamber or temperature platform.
 To keep cost/DUT low, the SS200's programmable load tuning capability adjusts internal drive circuitry to
 maintain pulse fidelity and fast transition times with simple twisted pair cables up to 10 meters in length.



 Easy To Use Control Software
 The Ethernet-controlled SpikeSafe 200 includes
 an interactive Control Panel application that may
 be used to control and operate from one to eight
 source channels. The Control Panel supports all
 source modes and it displays voltage and current
 readings read back from each source channel. For
 larger systems, optional SpikeSafe Test and
 Reliability Software ­ STARS ­ is available to
 control up to 256 source channels. Custom
 applications, such as part characterization and
 production test, can also be developed using
 available .Net and LabVIEW drivers.

                                                       SpikeSafe Test And Reliability Software
 FailSafe Temperature Monitoring
 In-situ temperature monitoring combined with STARS failsafe rapidly shuts down power to devices when
 device temperature exceeds user set thresholds.

 Available Stand-Alone or as Turn-Key System
 The SS200 can be provided as a stand-alone unit or as part of an integrated system. Integrated systems
 may include software and signal distribution hardware that can provide signal expansion to many DUTs
 and automatic failed DUT bypass. In-situ Vf, If, Tj, and R monitoring is also supported with available
 scanning and logging modules.


© Vektrex 2009                                                 For more information see www.vektrex.com or call 858-558-8282
    SS200 Precision Pulsed Current Source
    Targeted SpikeSafe Models Available For Many Applications
    The versatile SS200 is used for many applications ranging from quantum cascade laser burn-in to high
    power laser bar characterization. SS200 models are available to support many common uses. For
    applications outside of these, a custom model can be tailored to match a specific requirement. Contact
    Vektrex or a Vektrex representative to determine which source is best for a particular application.

     Models                     Features                                                  Typical Application
     SS200                      Standard unit, supports 10uS pulsing,                     Laser diodes, LED test and burn-in,
                                5A/channel                                                characterization
     SS200 - 10A                Standard unit, 10A maximum pulsed current,                High current devices
                                channel
     SS200 - 500mA DC           500mA maximum, improved low current                       Low current DC LED life test, low current devices
                                performance, DC only
     SS200 - Common Anode       1-6 channels                                              Production test of multi-chip modules with common
                                10A/channel                                               anode connection
                                Rapid current startup, floating output
     SS200FP ­ Fast Pulse       Standard unit with extended minimum pulse                 Laser diodes, LED test and characterization,
     (See separate datasheet)   width to 1uS,                                             quantum cascade lasers
                                adds low inductance output section
     SS200HC ­ High Current     High current model. Channels combined to                  Laser diode burn-in, rapid characterization, high
     (See separate datasheet)   supports up to 533A, 100V                                 voltage laser stacks


     Options                    Description                                               Typical Application
     Tj Measurement             Adds low current 0-25mA measurement                       Tj, R measurements
                                current source
     Modulated Current          Adds modulated current capability                         Rectifier ripple simulation, camera flash
                                                                                          sequences, power cycling test protocols




                                             Modulated Current Option
                                             The SS200 can provide arbitrary current waveforms with the
                                             Modulated Current Option. This option allows sequences of current
                                             steps to be defined and downloaded. Each step defines the current
                                             amplitude as a percentage of the set point and the step duration.
                                             Sequences can be nested and repeated to support applications
                                             such as rectifier ripple or a camera "red-eye" flash.


    Rectifier Ripple Waveform
                                                                                              Cooling Curve (Actual T ~ 20deg C)

    Tj Measurement Option                                                           40
                                                                                    35
    The Tj Measurement Option adds an adjustable low
                                                                     Temp (deg C)




                                                                                    30
    current measurement current source along with                                   25
    additional   firmware that   supports   junction                                20
                                                                                    15
    temperature (Tj) and thermal resistance (R)                                     10
    measurements using the JESD51-1 Electrical Test                                  5
    Method (ETM). For more information see the                                       0
                                                                                     0.0001     0.001      0.01              0.1   1          10
    SpikeSafe Tj Measurement Option datasheet.
                                                                                                                  Time (s)


                                                                    Cooling Curve Generated with Tj Option



© Vektrex 2009                                                                      For more information see www.vektrex.com or call 858-558-8282
SS200 Precision Pulsed Current Source

Standard SS200 Specifications

                           Output Configuration                                                     Pulse Performance
                    Current Sources:     1-8 channels/module                                         Modes:     DC, Single Pulse, Continuous
                               Type:     Differential drive, available floating                                 Pulse, DC Dynamic, Continuous
                                         or ground-referenced                                                   Dynamic
                   Output connector:     16 pin Molex Mini-fit JR                       Time base Accuracy:     +/-50 ppm
                              Remote Control                                             Pulse Width Range:     10uS ­ 1S
                            Physical:    100-base T Ethernet                          Pulse Width Resolution:   10nS
                            Protocol:    TCP/IP                                   Pulse Repetition Frequency    0.0025 Hz ­ 33 kHz
                     Command Set:        SCPI                                          Pulse Width Accuracy:    +/- 0.1% +/- 1uS, measured at 1A
                             Drivers:    .NET, LabVIEW                                        Rise/Fall Time:   1-10uS depending upon
            Read back Capability:        Voltage, current for each channel,                                     compensation settings*
                                         fault conditions                                       SpikeSafe Load Protection
                            Power Conversion                                                  Startup Shock:    Eliminated with 1S soft ramp-up
                               Type:     DSP-controlled two-stage step                      Current Anomaly:    Typically limited to less than
                                         down regulator                                                         400mA peak. Controlled to 5% of
                      Output Power:      1000W/channel maximum                                                  setpoint within 3uS
                             Losses:     20W/channel losses typical, 2-3x         Current Anomaly Shutdown:     Automatic shutdown when
                                         higher during current start-up                                         anomaly exceeds programmed
                         Duty Cycle:     Rated for continuous operation                                         threshold, shutdown within 3-10uS

                            Cooling:     Forced air                                         Voltage Anomaly:    Detected and logged, optional

                       Current Source Performance                                                               automatic channel shutdown

           Output Current Range:         0 ­ 5A per channel, see other                     Edge Undershoot:     Limited to ­100uA

                                         models for higher or lower currents                Edge Overshoot:     Limited to 20% for fast edge

    Maximum Compliance Voltage:          200V                                                                   setting; 0% slow edge setting

                 Setpoint Resolution:    100uA                                              Leakage Current:    Shutdown within 20mS of

                 Absolute Accuracy:      0.1%+2mA 0-5A, +/-1mA typical                                          cathode/anode current imbalance

                   Setpoint Stability:   +/- 50 ppm after 8 minute warm-up
            Output Current Ripple:       0.2% p-p typical, 200kHz, at 1A
                                Input Power
                   AC (2U Chassis):      90-240V, 400W maximum
                               Logic:    15VDC, 1.5A
           Bulk (If DC Bulk Used):       0-220V, 40A maximum
                     Bulk connector:     2 pin Molex Mini-fit SR
                                  Physical
                             Weight:     27 lbs
                                Size:    2U rack mount 24.5"vx 19" x 3.5"
                                    Other
                     Trigger Output:     Active low, 13uS after pulse start            *Typical 5A, 10 uS current pulse
                    Isolated Disable:    Halts current output                         showing 1uS rise time, flat top, and
                                                                                             controlled fall time

                   CompuMess Elektronik GmbH
              For more information see www.vektrex.com
         Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
       Telefon (089) 32Contact: Melissa Ford 32 15 01 - 11
                         15 01 - 0 · Telefax (089)
           info@compumess.de · 558-8282 x6
                      Phone: (858) www.compumess.de
                        melissa@vektrex.com
                          www.netzteile.de
© Vektrex 2009                                                                    For more information see www.vektrex.com or call 858-558-8282