Hier Klicken für das PDF Dokument!!!
115 WATTS
NO MINIMUIM ORDER REQUIRED
SRW-115 SERIES OUTPUT SPECIFICATIONS
Features Total Output Power 110W
at 50o C
Universal 85-264 VAC Input Output Voltage Output 1: +/-1.0%
High Efficiency Centering Output 2: +/-5.0%
Compact 4025" X 7" X 1.25" Size Output 3: +/-5.0%
Output 4: +/-5.0%
2 Year Warranty
(All outputs at 50% rated load)
Fits 1U Applications Source Regulation Outputs 1-4: 0.5%
One to Four Outputs Load Regulation Output 1: 1.0% (10-100%
EN 60950 ITE Certification Load Change)
Class B Emissions Per EN 55022 Output 2: 5.0% (10-100%
Optional Chassis & Cover Load Change)
Output 3: 5.0% (10-100%
Load Change)
Output 4: 5.0% (10-100%
Load Change)
Cross Regulation Output 2: 5.0% Output 1
load
varied
50-100%
Output 3: 5.0%
Output 4: 5.0%
Output Voltage Output 1: 95-105%
GENERAL SPECIFICATIONS Adjust Range
Output Noise Outputs 1-4: 1%
Dielectric Strength
Turn On Overshoot None
Reinforced Insulation4242 VDC, Primary to Transient Response Outputs 1-4
Secondary, 1 Sec.
Voltage Deviation 5.0%
Basic 2121 VDC, Primary to
Recovery Time 2mS
InsulationGround, 1 Sec. Load Change 50% to 100%
Operational Insulation500 VDC, Secondary to Output Overvoltage Output 1: 110% to 150%
Ground, 1 Sec.
Protection (Optional)
Power Fail Signal Logic low with input power
Output Overpower Outputs 1-4: 110% Min
(optional) failure 2mS minimum prior Protection Outputs cycle on/off, auto
to output 1 dropping 1% recovery
Mean Time Between 150,000 Hours min.,
Hold Up Time 16 mS min., 115W, 120V Input
Failures MIL-HDBK-217F, 25oC, GB
Start Up Time 1 Second
Weight 1.30 Lbs. Open Frame
2.25 Lbs. Chassis and
Cover
INPUT SPECIFICATIONS ENVIRONMENTAL SPECIFICATIONS
Source Voltage 85-264 Volts AC Ambient Operating 0 oC to +70oC Derating:
Frequency Range 47-63 Hz Temperature Range See Power Rating Chart
SourceCurrent Ambient Storage Temp.
-40 oC to +85oC
True RMS 3.5A at 85V Input Range
Peak Inrush o
40A Temperature Coefficient Outputs 1-4: 0.02%/ C
Efficiency .72-.80 (Varies by model) Conducted Emissions En55022 Class B
CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de
ELECTROMAGNETIC COMPATIBILITY
Electrostatic Discharge EN 61000-4-2 +/-8kV Contact Discharge
+/-8kVAir Discharge
Radiated Electro-magnetic Field EN 61000-4-3 80MHz-2.5GHz, 10V/m, 80% AM
EFT/Bursts EN 61000-4-4 +/-2kV
Surges EN 61000-4-5 +/-1 kV Differential Mode
+/-2 kV Common Mode
Conducted Immunity EN 61000-4-6 .15-80MHz., 10V, 80% AM
Voltage Dips and Interruptions EN 61000-4-11 30% Reduction
95% Reduction
60% Reduction
95% Reduction
Radiated Emissions EN 55011/22 Class B
Conducted Emissions EN 55011/22 Class B
Harmonic Current Emissions EN 61000-3-2
Voltage Fluctuations and Flicker EN 61000-3-3
MODEL LISTING
Model Output 1 Output 2 Output 3 Output 4
SRW-115-4001 +5V/12A -5V/4A +12V/4A -12V/2A
SRW-115-4002 +5V/12A +24V/1A +12V/4A -12V/2A
SRW-115-4003 +5V/12A -5V/4A +15V/3A -15V/2A
SRW-115-4004 +5V/12A +24V/1A +15V/3A -15V/2A
SRW-115-4005 +5V/12A +12V/1A +24V/3A -12V/1A
SRW-115-4006 +5V/12A +12V/3A +15V/2A -15V/2A
SRW-115-4007 +5V/12A +12V/2.5A +24V/2A -5V/1A
SRW-115-4008 +24V/12A +5V/3A +5V/2A -24V/2A
SRW-115-4011 +5V/5A +15V/1A +24V/5A -15V/1A
SRW-115-4013 +5V/13A +5V/5A +12V/3A -5V/3A
SRW-115-4012 +5V/5A +12V/1A +24V/3A -12V/1A
SRW-115-4014 +3.3V/12A +5V/4A +15V/3A -15V/2A
SRW-115-4015 +3.3V/12A +5V/4A +12V/4A -12V/2A
SRW-115-4016 +5.2V/12A +12V/4A -12V/2A -2V/9A
SRW-115-4017 5V/8A 19V/1A 19V/2A 54.5V/.5A
SRW-115-4019 15V/3A -15V/2A +24V/2A 3.3V/1A
SRW-115-4020 15V/3A -15V/2A +36V/1.5A 3.3V/1A
SRW-115-4102 5V/12A 12V/2A +12V/4A -12V/25A
SRW-115-3001 +5V/12A +12V/4A -12V/2A
SRW-115-3002 +5V/12A +15V/4A -15V/2A
SRW-115-3003 +5V/12A +24V/3A -12V/1A
SRW-115-3004 +5V/12A +24V/1A +12V/6A
SRW-115-3005 +15V/3A -15V/2A +24V/2A
SRW-115-3006 +15V/3A -15V/2A +36V/1.5A
SRW-115-3007 +15V/14A -5V/4A +12V/4A
SRW-115-2001 +5V/12A +24V/3A
SRW-115-2002 +12V/5A -12V/5A
SRW-115-2003 +15V/5A -15V/5A
SRW-115-2004 +24V/2.5A -24V/2.5A
SRW-115-2005 +5V/12A +15V/5A
SRW-115-2006 +5V/12A +12V/5A
SRW-115-2007 +17V/3.4A -17V/3.4A
SRW-115-2008 +9.25V/6A -9.25V/6A
SRW-115-2010 +7.5V/10A -7.5V/6A
SRW-115-2011 +28V/2A -28V/2A
SRW-115-2012 +12V/8A 12V/2A
CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de
Notes
Consult factory for alternate output configurations.
Consult factory for positive, negative or floating outputs.
Refer to Application Information for complete output power ratings.
All specifications are maximum at 25o C unless otherwise stated and are subjected to change without
notice.
Specify optional chassis and cover, power fail, overvoltage protection or DC Input when ordering.
TUV only: SRW-115-3004, SRW-115-3005, SRW-115-4016, SRW-115-4019, SRW-115-4020
UL, CUL only: SRW-115-2011, SRW-115-4007, SRW-115-4008, SRW-115-4012
SAFETY SPECIFICATIONS
General Protection Class: I
Overvoltage Category: II
Pollution Degree: 2
Underwriters UL 60950, Third Edition
Laboratories
File E137708
UL Recognition Mark for CAN/CSA-C22.2 No. 60950:00
Canada
File E137708
TUV EN 60950:2000
Low Voltage Directive
CB Report per IEC 950(1991)
Second Edition A1, A2 and
All national deviations
SRW-115 SERIES MECHANICAL SPECIFICATIONS
CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de
CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim
Tel 089-321501-0 · Fax 089-321501-11 · www.compumess.de · www.netzteile.de
APPLICATIONS INFORMATION
1. Each output can deliver its rated load but total Maximum Output Power vs. Ambient
output power must not exceed 115 watts. Temperature
2. Semiconductor case temperatures must not
exceed 110o C.
3. Sufficient area must be provided around the
convection cooled power supplies to allow
natural movement of air to develop.
4. This product is intended for use as
professionally installed component within
information technology and medical equipment.
5. A minimum load of 20% is required on output
one to insure proper regulation of remaining
outputs.
6. Peak to peak output ripple and noise is
measured directly at the output terminals of CONNECTOR SPECIFICATIONS
the power supply, without the use of the probe .156 friction lock header mates with
ground lead or retractable tip, 20 MHz Molex 09-50-3051 or equivalent crimp
bandwidth. AC Input
TB1 terminal housing with Molex
7. This product was type tested and safety 08-50-0189 or equivalent crimp
certificated using the the dielectric strength terminal.
test voltages listed in Table V .156 friction lock header mates with
of UL 60601-1. In consideration of clause Molex 09-50-3101 or equivalent crimp
20.4g, care must be taken to insure the voltageTB1 DC terminal housing with Molex
applied to a reinforced insulation Output
08-50-0189 or equivalent crimp
does not over stress basic insulation. terminal.
Secondary to ground capacitors may need to bePF power fail signal
removed prior to performing TB2-7,8 power fail signal return
a dielectric strength type test on the end RECOMMENDED AIR FLOW DIRECTION
product. It is highly recommended that the DC
1.Optimum 2.Good 3.Fair
test voltages listed in DVB.1. Annex DVB are
not exceeded during a production-line dielectric
strength
test of the assembled end product. Please
consult factory for further information.
8. This power supply has been safety approved
and final tested using a DC dielectric strength
test. Please consult factory before performing
an AC dielectric strength test.
9. Maximum screw penetration into chassis
mounting holes is .250 inches.
CompuMess Elektronik GmbH · Lise-Meitner-Str.1 · 85716 Unterschleissheim