Hier Klicken für das PDF Dokument!!!

Smart Choice for power




SmartWave Control Suite Version 3




                                                                                                                                     AC and DC Power Bus Simulation
                                                                                                                                     AC Input Compliance Testing
                                                                                                                                     Avionics Test




SmartWaveTM Control Suite (SWCS) version 3.0 puts the power of the SmartWave Series of
AC power sources in your hands. Controlling a SmartWaveTM has never been easier!

                                                                                                                                                Programmable Division
Version 3 Improvements                                                                                                                          Xantrex Technology Inc.
                                                                                                                                                9250 Brown Deer Road
      -On-the-flywaveformediting                                                                                                                San Diego, CA
      - View actual waveforms in sequences                                                                                                      USA 92121
      -Easysequencesetup:insert,addsteps,viewsteps,globalmodifications                                                                          800 733 5427 Toll Free
      - Supports Applications Test suites and Elgar Avionics Compliance System                                                                  858-450-0085 Main
                                                                                                                                                858 458 0267 Fax
SWCS is a Windows-based software package for computer control of the SmartWaveTM series of AC pro-
grammable power sources. With SWCS 3.0, you have complete control of the instrument including setup,
programming, waveform and sequence creation. SWCS enhances the standard SmartWave features with
an additional harmonic waveform analysis capability with data logging features for all measurements.
Version3hasbeendesignedfromthegrounduptoallowmoreflexibilityinwaveformandsequence
creationwhilereducingtheprogramsize.Inaddition,itsupportsallcurrentandfutureapplicationspecific
testsuitesandcompliancesystems,suchasthoserequiredfortestingtoAirbusandBoeingspecifications
(see below). SWCS ships as standard with all SmartWaveTM series of AC programmable power sources.
An upgrade is also available for existing customers.


Applications Test Suites
Applications Test Suites provide an automatic method to generate standards-based stimulus waveforms
through the SmartWaveTM series of AC programmable power sources. These software packages save
hundreds of hours of development time allowing users to simply select and execute either single tests or a
sequence of tests compliant with the standard.
      - Automated compliance test waveforms
      - Save hundreds of hours in developing and verifying waveforms.
      - Simulate AC or DC Buses or any combination.
FromSWCS3.0,theuserselectstherequiredtestspecification.TheTestSuiteautomaticallyliststhe
                                                                                                                                                www.programmablepower.com
                                                                                                    CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
                                                                                                    Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
© 2007 Xantrex Technology Inc. All rights reserved. Xantrex is a registered trademark of Xantrex International.

                                                                                                    info@compumess.de · www.compumess.de · www.netzteile.de
  Smart Choice for power



testsavailableforthatspecification.Onceselected,thetestsmaybelooped,
                                                                                                  Applications Test Suite Ordering Information
single stepped, or multiple tests selected and run in a series. During execu-
                                                                                                  Part Number         Specification        Description
tion, test status is displayed in three progress windows with total test time,
individual or sequence time and progress within a test, or segment time.                          ABD100TSS-A         Airbus ABD100        Table A tests only (115VAC/400Hz)
                                                                                                  ABD100TSS-B         Airbus ABD100        Table B tests only (26VAC/400Hz)
Test Selector also allows the user to easily build a test sequence from the
                                                                                                  ABD100TSS-C         Airbus ABD100        Table C tests only (115VAC/variable freq)
library of compliance tests. Detailed descriptions of each test are provided
for convenience as well as the capability of saving a test sequence for future                    ABD100TSS-DE        Airbus ABD100        Table D & E tests only (Conventional and
                                                                                                                                           NBPT dc)
recall.Individualtestscanbeeasilymodifiedandsavedformargintesting.
                                                                                                  AMD24T-SVF/SCF      Airbus AMD24         Table SVF/SCF only
                                                                                                  AMD24T-TVF/TCF      Airbus AMD24         Table TVF/TCF only
Elgar Avionics Compliance System
                                                                                                  AMD24T-LDC          Airbus AMD24         Table LDC only
The EACS is a targeted test system which generates power bus test
                                                                                                  AMD24T-FULL         Airbus AMD24         Tables SVF/SCF, TVF/TCF, LDC
stimulus/anomalies, device under test (DUT) measurement (voltage, current,
                                                                                                  B787PQ-1PH          Boeing 787           Single phase AC tests (115V and 235V)
timing, digital I/O) and reporting in one easy-to-use package.
                                                                                                  B787PQ-3PH          Boeing 787           Three phase AC tests for 115V and 235V
     - Automatically generate test reports
                                                                                                  B787PQ-28V          Boeing 787           Tests for 28V DC bus
     - Save data for each test for later recall
                                                                                                  B787PQ-270V         Boeing 787           Tests for 270V DC bus
     - Approve each test result during report generation
                                                                                                  B787PQ-FULL         Boeing 787           Single phase, 3 phase, 28VDC, 270VDC
At the click of a few buttons, you can now fully test your avionics subsystem                                                              tests for Boeing 787
according to Airbus, Boeing, DO-160 or MIL-STD 704 requirements. Utilizing                        EN2282T-AC          BSI                  AC tests for Characteristics of Aircraft
the SmartWave AC power source, applicable SmartWave Control Suite                                                                          Electrical Supplies

(SWCS) Application Test Suite and a Yokogawa ScopeCorder, just connect                            EN2282T-DC          BSI                  AC tests for Characteristics of Aircraft
                                                                                                                                           Electrical Supplies
your unit for test, click through the software to run the tests and generate a
                                                                                                  EN2282T-FULL        BSI                  All tests for Characteristics of Aircraft
compliance report.                                                                                                                         Electrical Supplies

                                                                                                  Elgar Avionics Compliance System Ordering Information
                                                                                                  Part Number         Description
                                                                                                  EACS-ABD100-1F      ABD100TSS-ABCDE, SWCS 3, 6 Channel Yokogawa Scope-
                                                                                                  EACS-ABD100-1F-EU   Corder, Report generator/storage utility/drivers

                                                                                                  EACS-ABD100-3F      ABD100TSS-ABCDE, SWCS 3, 10 Channel Yokogawa Scope-
                                                                                                  EACS-ABD100-3F-EU   Corder, Report generator/storage utility/drivers

                                                                                                  EACS-ABD100-S       ABD100TSS-ABCDE, SWCS 3, Report generator/storage util-
                                                                                                  EACS-ABD100-S-EU    ity/drivers

                                                                                                  EACS-AMD24-1F       AMD24-FULL, SWCS 3, 6 Channel Yokogawa ScopeCorder,
                                                                                                  EACS-AMD24-1F-EU    Report generator/storage utility/drivers

                                                                                                  EACS-AMD24-3F       AMD24-FULL, SWCS 3, 10 Channel Yokogawa ScopeCorder,
                                                                                                  EACS-AMD24-3F-EU    Report generator/storage utility/drivers

                                                                                                  EACS-AMD24-S        AMD24-FULL, SWCS 3, Report generator/storage utility/drivers
    Smartwave Control Suite sequence screen                                                       EACS-AMD24-S-EU
                                                                                                  EACS-B787-1F        B787PQ-FULL, SWCS 3, 6 Channel Yokogawa ScopeCorder,
                                     GPIB
                                                                                                  EACS-B787-1F-EU     Report generator/storage utility/drivers
                                   Connection


                   SWCS 3.0
                                                Output        F1     1   2   3
                Report Generator
                                                                                                  SmartWave Control Suite 3.0 Ordering Information
                                                              F2     4   5   6

                 Database Mgr.                                F3     7   8   9

                    Drivers                                   Help   .   0   +/-   Enter   Menu




                                                                                                  Part Number          Description
                                                                                                  SWCS3.0              SmartWave Control Suite 3.0 included with purchase of a
                                                                                                                       SmartWave AC power source.
    Ethernet                                                                                      SWCS-UPG             Upgrade from a previous version of SWCS to current version.
   Connection


                                                                                                  Minimum System Requirements
                                               V/I/F
                                            Measurement                                               - SWCS 3.0 or higher for Test Suites and Compliance Systems
                                                                                                      - SmartWaveTM, ECDI rev. 5.05 or higher, DWSB rev. 2.4
                                                                                                      - Computer with Pentium II 500MHz, 256MB, 500MB available
                                                   UUT                             UUT                   on hard disk, CD-ROM, Windows XP/2000
                                                Measurement
                                                                                                      - Internet Explorer 5.0 or higher
    EACS System Diagram                                                                               - National Instruments GPIB card and interface cable