Hier Klicken für das PDF Dokument!!!

TW Series
AC Power Sources
TrueWave
AC Power Sources
Applications
The TrueWave (TW) is designed for
testing today's complex electronics,
including military and commercial
applications requiring DC and
sine wave testing. The TW is ideal
for testing electronic equipment
for compliance to new European
Standards such as harmonics. Other
applications include:                    Output Current Per Phase: 13A to                        MEASUREMENTS
                                         135V in 156V range; 6.5A to 270V in
· Test environments that require field   312V range (1750 VA max.)                      ·  Phase to Phase RMS Output Voltages
   configurable parallel operation       Power Factor of Load: 0 lagging to
                                                                                        ·  RMS Output Currents
· Testing for real world DC single       0 leading                                      ·  Peak Current
   or polyphase AC power conditions                                                     ·  Output Frequency
                                         Crest Factor: 4.0 (peak output current
· Automatic Test Equipment (ATE)         to RMS output current)                         ·  1ø to 3ø Power
· General AC and DC Avionics                                                            ·  1ø to 3ø VA
                                         Output Frequency Range: 40 Hz to
   Testing                               500 Hz                                         ·  Power Factor
· Power Supply testing for AC-DC,                                                       ·  Output Phase Angles Relative to
                                         Max. Total Harmonic Distortion (Full
   DC-DC converters and UPS's                                                              Phase A
                                         Linear Load or No Load): 0.3% max.
· Testing to European Standards                                                         Measurement Accuracy: All at 25°± 5°C
   including EN 61000-3-2                AC Noise Level: 60 dB RMS below
                                         full output voltage                            Power: 2.5% of full scale
· AC Ballast testing
   (IES LM-41-1985)                      Amplitude Stability With Remote                Voltage: 0.3% of full scale + 0.2%
                                         Sense: ±0.1% of full scale over 24             of reading
                                         hours at constant line, load and               Current: 0.3% of full scale + 0.5%
Specifications                           temperature                                    of reading
                                         Line Regulation: 0.05% of full scale
             OUTPUT                      ±10% change
                                                                                        Apparent Power: 2.5% for output
Output Power: 1750, 3500 or                                                             > 200 VA
5250 VA                                  Load Regulation: 0.15% of full scale           Frequency: 0.25%
Output Phase: 1750 VA, 1 phase;          Voltage Accuracy: ±0.01% of full scale         Phase: 0.5°
3500 VA, 1 or 2 phase; 5250 VA, 1, 2     Voltage Resolution: 0.03% of full scale
or 3 phase
                                         Frequency Resolution: 0.1 Hz
AC Output Voltage: 0 to 156 VRMS,
L-N low range; 0 to 312V RMS L-N         Phase Accuracy, Phase-to-Phase
high range                               Balanced Linear Resistive Load: ±1°

DC Output Voltage: 0 to 223V low         Phase Angle Resolution: 0.1°
                                                                                   CompuMess Elektronik GmbH
range; 0 to 445V high range              Remote Output Voltage Sense: 5V RMS         Lise-Meitner-Str.1, 85716 Unterschleissheim
                                         total lead drop, max.                          Tel 089-321501-0 Fax 089-321501-11
                                                                                   http://www.compumess.de oder http://www.netzteile.de
              INPUT                     Shipping Weight: US/International
                                        · TW 1750A - 130 lbs. (59 kg)
                                                                                                                  OTHER STANDARD
Input Voltage Ranges: Factory config-
                                        · TW 3500A - 153 lbs. (69.5 kg)                                              FEATURES
ured 187 to 264 VRMS, 3ø L-L
(3 wire), or 342 to 457 VRMS,           · TW 5250A - 178 lbs. (80.9 kg)                                  · 1ø to 3ø programmable
3ø L-L (4 wire). A chassis ground is                                                                     · IEEE 488.2 interface and RS 232
also required.                                          GENERAL                                            SCPI protocol
                                        Cooling: Air is drawn in primarily                               · Waveform trigger output
Input Power Factor: 0.6 (0.99 with
input PFC option, 0.35 for European     from the front, but also from the
                                        top, bottom, and sides and exhausted                               (1 Meg Load Drive)
rectifier input)                                                                                         · Sync out
                                        through the rear.
Input Frequency Range: 47 to 63 Hz                                                                       · Analog remote control
                                        Operating Temperature: 0°C to 45°C
Efficiency: 70% min., at full load      (32°F to 113°F)                                                  For programmed settings:
Ride Through: 3 msec, min. for recti-   Storage Temperature: -40°C to 70°C                               · Sync out selections are:
fier input; 10 msec, min., with PFC     (-40°F to 158°F)                                                   Even Cycle A phase (on)
option                                                                                                   · None (off)
                                        Humidity (non-condensing): 0 to 85%,
 PROTECTION AND SAFETY                  31°C (88°F); derate to 50% at 40°C                               · When change in programmed
                                        (104°F)                                                             parameters occur (event)
Overvoltage Shutdown:
Programmable for 20V to 255V            Altitude: Operating 6,500 ft.,                                   · External Summing Node 0 to 5V
peak, 156V range; 40V to 510V           non-operating 40,000 ft.                                           RMS provides 0 to 100% output
peak, 312V range                        Certifications: CE marked and FCC                                                  OPTIONS
Programmable Current Limit              compliant
Shutdown: Settable to 1% of range                                                                        · Input power factor correction to
                                        Calibration Interval: 1 year
(0.5A to 13A for 156V range; 0.5A                                                                          0.99 (-3 or -4 model numbers
to 6.5A for 312V range)                                                                                    only)
Programmable Current Limit with
Timed Shutdown: Settable to 1% for
range. The timeout is settable from     Ordering Information
10 msec to 10 sec.
Programmable Constant Current:            Model Number       Output Power Rating                     AC Input                Power Factor Correction
Settable to 1% of range (0.5A to 13A
for 156V range; 0.5A to 6.5A for          TW 1750-1                 1750 VA1              187-264 VRMS (L-L), 3-wire                   no
312V range). For all current accura-      TW 1750-2                 1750 VA   1
                                                                                          342-457 VRMS (L-L), 4-wire                   no
cies, add ±1.5%/kHz above 500 Hz.
For paralleled amplifiers, add ±1%.       TW 1750-3                 1750 VA1              187-264 VRMS (L-L), 3-wire                  yes
                                                                              1
Overtemperature Shutdown:                 TW 1750-4                 1750 VA               342-457 VRMS (L-L), 4-wire                  yes
(automatic, not programmable)             TW 3500-1                 3500 VA2              187-264 VRMS (L-L), 3-wire                   no
PHYSICAL SPECIFICATIONS                   TW 3500-2                 3500 VA   2
                                                                                          342-457 VRMS (L-L), 4-wire                   no
Height: 8.75 in (222 mm)                  TW 3500-3                 3500 VA2              187-264 VRMS (L-L), 3-wire                  yes
Width: 19 in (483 mm)                     TW 3500-4                 3500 VA   2
                                                                                          342-457 VRMS (L-L), 4-wire                  yes
Depth: 23.5 in (597 mm)                   TW 5250-1                 5250 VA   3
                                                                                          187-264 VRMS (L-L), 3-wire                   no
Weight:                                   TW 5250-2                 5250 VA3              342-457 VRMS (L-L), 4-wire                   no
· TW 1750A - 60 lbs. (27.3 kg)            TW 5250-3                 5250 VA   3
                                                                                          187-264 VRMS (L-L), 3-wire                  yes
· TW 3500A - 83 lbs. (37.7 kg)            TW 5250-4                 5250 VA3              342-457 VRMS (L-L), 4-wire                  yes
· TW 5250A - 108 lbs. (49 kg)
                                         1. 1495 VA at 230V output, 2. 2990 VA at 230V output, 3. 4485 VA at 230V output




                                                      CompuMess Elektronik GmbH
                                                        Lise-Meitner-Str.1, 85716 Unterschleissheim
                                                           Tel 089-321501-0 Fax 089-321501-11
                                                      http://www.compumess.de oder http://www.netzteile.de                                    TW0800