Slimline Plug & Play Power Supply Series 200W/400W/600W
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
lite
Slimline
Slimline Power Supply patents pending
User Configurable 1U size
The Xlite family of power supplies provides up to 600W in a slimline 1U x 260 x
PLUG & PLAY POWER 89mm package. Providing up to 8 isolated outputs, the Xlite family is the most
next generation power source flexible power supply in its class and brings affordable configurable power to the
200-600W market.
FEATURES The slimline product boasts unrivalled power density saving valuable system space.
Combine with ultra high efficiencies, the Xlite family provides system designers with
· Slimmest 600W configurable power
flexible instant solutions that significantly shorten and simplify system design-in time.
· 750W available (see XLD datasheet)
· Extra low profile: 1U height (40mm) The Xlite family consists of 3 powerPac models in 200W, 400W and 600W power levels.
· All outputs fully floating Each powerPac model may be populated with up to 4 powerMods selected from the
· Ultra high efficiency, up to 89% table of powerMods shown below.
· Plug & Play Power
All configurations carry full safety agency approvals, UL60950, EN60950 and are CE
- allows fast custom configuration marked. For alternative power interfaces contact support@excelsys.com CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
- allow easy logistics info@compumess.de · www.compumess.de · www.netzteile.de
· FLEXIMOUNT Flexible mounting system
powerMods powerPacs
· Few electrolytic capacitors (all long life)
MODEL Vmin(4) Vnom Vmax(4) Imax Watts MODEL Watts
· Visual LED indicators Vtrim Vpot
· Series / Parallel of multiple outputs XLA 200W
Xg1 1.0 1.5 2.5 3.6 50A 125W
· 5V bias standby voltage provided XLB 400W
· Individual output control signals Xg2 1.5 3.2 5.0 6.0 40A 200W
XLC 600W
Xg3 4.0 6.0 12.0 15.0 20A 240W
XLD 750W
APPLICATIONS INCLUDE Xg4 8.0 12.0 24.0 30.0 10A 240W
· Industrial machines See XLD datasheet
Xg5 8.0 24.0 48.0 58.0 6A 288W
· Test and measurement Xg7 5.0 5.0 24.0 28.0 5A 120W
· Automation equipment
Xg8 V1 5.0 5.0 24.0 28.0 3A 72W
· Printing V2 5.0 5.0 24.0 28.0 3A 72W
· Telecommunications
· For Medical applications see Xmite
EFFICIENCY (typical) MECHANICAL SPECIFICATIONS
93 1
92 Third angle projection
91 50.00 97.75
Efficiency %
90
46.00 122.00 92.00
89
J1
70C MAX OPERATING TEMPERATURE
SEE INSTRUCTION MANUAL
INPUT AC 100V-240V 50/60Hz
88 23.50
SLOT D
87
J2
SLOT C
42.00 19.00 89.00
86 TOP VIEW
SLOT B
85
23.50 SLOT A
84
70 85 100 115 130 145 160 175 190 205 220 235 260
Line Voltage VAC
40.40 29.50
All dimensions in mm.
Mounting Holes
4 M4 threaded holes on Base. Max screw penetration is 6mm from Base.
Series Fleximount Side Mounting Slots
Use with self-clinching studs type FH-M4-X or FH-832-X (X= stud length) from PEM, or equivalent
Alternatively, use Xgen Side Clamps from Excelsys. Part No. Z165 (drawing 61401)
200W/400W/600W Slimline Plug & Play Power Supply Series
SPECIFICATION applies to configured units consisting of powerMods modules plugged into the appropriate powerPac
INPUT
Parameter Conditions/Description Min Nom Max Units
Input Voltage Range Universal Input 85 264 VAC
120 380 VDC
Input Frequency Range 47 63 Hz
Slimline
Power Rating XLA/XLB/XLC Derate linearly from 600W at 180VAC to 400W at 85VAC 200/400/600 W
Input Current XLA/XLB/XLC 85VAC in 4.0 4.0/6.0/7.5 A
Inrush Current 230VAC @ 25°C 50 A
Undervoltage Lockout Shutdown 65 74 VAC
Fusing XLA 250V 5 x 20mm F5A HRC
XLB 250V 5 x 20mm F6.3A HRC
XLC 250V 5 x 20mm F8A HRC
OUTPUT
Parameter Conditions/Description Min Nom Max Units
powerMod Power As per powerMod table
Output Adjustment Range Manual: Multi-turn potentiometer. As per powerMod table
Electronic: See Xgen Designers' Manual
Minimum Load 0 A
Line Regulation For ±10% change from nominal line ±0.1 %
Load Regulation For 25% to 75% load change ±0.2 %
Cross Regulation ±0.2 %
Transient Response For 25% to 75% load change Voltage Deviation 10 %
Settling Time 250 µs
Ripple and Noise 20MHz Bandwidth 1.0 % pk-pk
Overvoltage Protection Two-level. 1st level: Vset Tracking. 2nd level: Vmax (Latching) 110 125 %
Overcurrent Protection Straight line with hiccup activation at <30% of Vnom 110 120 %
See Designer's Manual for full details
Remote Sense Max. line drop compensation. (except Xg7, Xg8) 0.5 VDC
Overshoot 2 %
Turn-on Delay From AC In / Enable signal 600 / 30 ms
Rise Time Monotonic 5 ms
Hold-up Time For nominal output voltages at full load 20 ms
Output Isolation Output to Output / Output to Chassis 500 / 500 VDC
GENERAL
Parameter Conditions/Description Min Nom Max Units
Isolation Voltage Input to Output 3000 VAC
Input to Chassis 1500 VAC
Efficiency 230VAC, 400W @ 24V 89 %
Safety Agency Approvals EN60950, UL60950, CSA22.2 No.950 UL File No. E181875
Leakage Current 250VAC, 60Hz, 25°C 1.5 mA
Signals See Xgen Series datasheet
Bias Supply Always ON. Current 250mA 4.8 5.0 5.2 VDC
Reliability Failures per million hours at 25°C and full load powerMod 0.98 fpmh
See Designers' Manual. powerPac excludes fans powerPac 0.92 fpmh
EMC
Parameter Standard Level Units
Emissions
Conducted EN55011, EN55022, FCC Level B
Radiated EN55011, EN55022, FCC Level B
Harmonic Distortion EN61000-3-2 Compliant
Flicker and Fluctuation EN61000-3-3 Compliant
Immunity
Electrostatic Discharge EN61000-4-2 Level 4
Radiated RFI EN61000-4-3 Level 3
Fast Transients - burst EN61000-4-4 Level 4
Input Line Surges EN61000-4-5 Class 4
Conducted RFI EN61000-4-6 10 V/m
Voltage Dips EN61000-4-11 (EN55024) 10 ms
2 ENVIRONMENTAL
Parameter Conditions/Description Min Nom Max Units
Operating Temperature -20 +70 °C
Storage Temperature -40 +85 °C
Derating 2.5% per °C above 40°C. See Designers Manual for full deratings
Relative Humidity Non-condensing 5 95 %RH
Shock 3000 Bumps, 10G (16ms) half sine
Vibration 1.5G 10 200 Hz
NOTES 1. This product is not intended for use as a stand alone unit and must be installed by qualified personnel.
2. The specifications contained herein are believed to be correct at time of publication and are subject to change without notice.
3. All specifications at nominal input, full load, 25°C unless otherwise stated.
4. Vmin and Vmax voltages achieved when using Vtrim function on powerMod or the on board potentiometer. Vtrim is the lowest voltage that can be
achieved using Vtrim pin on powerMod. Vpot is the minimum voltage that can be achieved using the on-baord potentiometer. See Xgen series
Designers' Manual for full details on Vtrim and adjustment ranges.
5. When powering inductive or capacitive loads, it is recommended to use a blocking diode on the output.
Doc. 40038 rev. 08 11/09
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Xgen FLEXIBILITY and SIGNALS
Voltage Adjustment - Local Temperature Alarm (Option 01)
The multi-turn potentiometer that adjusts each output within the speci- Open collector signal indicating excessive powerPac temperatures due
fied range may be accessed via the output panel of the power supply. to fan failure or operation beyond ratings. This signal is activated at
Clockwise rotation increases output voltage. Resolution is approximate- least 10ms prior to system shutdown.
ly 5% of nominal voltage (Vnom) per turn.
Fan Fail (Option 01)
Voltage Adjustment - Remote (resistive / electronic) Open collector signal indicating that at least one of the system fans
The output voltage may be adjusted or trimmed by means of an exter- have failed. This does not cause system shutdown.
nal resistor or potentiometer network connected to the Vtrim pin. Linear
Electronic programming is also possible and may be implemented
according to the formula Vout = K Vcontrol. See Xgen series
Designers' Manual for full details.
Paralleling
To achieve increased current capacity, simply parallel outputs using the
standard parallel links. Excelsys `wireless' sharing ensures that current
hogging is not possible. To parallel connect outputs:
1. Switch on IShare switch to ON on powerMods.
2. Connect Negative parallel link.
3. Adjust output voltages of powerMods to within 5mV of eachother. Power Good
4. Connect Positive Parallel Link. Opto-isolated output signal indicates that the powerMod is operating
Parallel Links available to correctly and output voltage is within normal band.
order. Part Number XP1 Opto transistor ON = Good.
Seriesing
To achieve increased output voltages, simply series outputs using stan-
dard series links, paying attention to the requirements to maintain Indication LEDs
SELV levels if required in your system. Each powerMod has a visual indicator to identify that it is operating
Series Links available. Part within normal ratings. Very useful for system diagnosis.
Number XS1
Signal Connector Pinout
Pin J2 (powerPac) J3 (powerMod) J3 (powerMod)
Type A Type B)
Remote Sensing 1 common +sense +pg (V2)
2 +5V bias -sense -pg (V2)
When the load is remote from the power supply, the remote sense
pins may be used to compensate for drops in the power leads. 3 V trim inhibit (V2)
Where the power cabling contributes significant dynamic impedance, 4 ac fail I trim common (V2)
see Xgen series Designers' Manual. 5 fan fail* +inhibit/enable +pg (V1)
6 global enable -inhibit/enable -pg (V1)
Bias Voltage 7 temp alarm* +power good inhibit (V1)
A SELV isolated 5V (always on) bias voltage rated at 250mA is pro- 8 global inhibit -power good common (V1)
vided on J2 to facilitate miscellaneous control functions.
*Option 01 only
Current Limit Adjustment Signal Connector Pinout
The output current limit setting may be adjusted (downwards only) TYPE A Xg1-Xg7 TYPE B : Xg8
by means of an external resistor connection to the I trim pin.
Inhibit/Enable J3 J3
Inhibiting may be implemented either globally or on a per module Voltage V1 Adjust
3 Adjust
basis (powerPac or powerMod inhibiting). Reverse logic (Enabling)
V2 Adjust
may also be implemented, see Xgen series Designers' Manual. 2 1 2 1
J4
J4
AC Fail 4
Open collector signal indicating that the input voltage has failed or is 2
3
less than 80Vac. This signal changes state giving 5mS of warning
before loss of output regulation. See Xgen series Designers' Manual
2
for full specifications.
1
1
M4 Screws
J4 Connector : M4 Screw J4Connector : Camden 9200/4A
J3 Connector Mating Connector J3 Connector Mating Connector
Housing: Locking Molex 51110-0860 Housing: Locking Molex 51110-0860
Non Locking Molex 51110-0850 Non Locking Molex 51110-0850
Crimp Termnal: Molex p/n 50394 Crimp Termnal: Molex p/n 50394
See Xgen series Designers' Manual for full signal connector details.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Xgen Plug & Play Power Supply Series 200W to 1340W
Series
powerPacs (4slot package, 89mm wide)
Family MODEL Watts Family MODEL Watts
Xlite XLA 200W Xmite XMA 200W
Standard
XLB 400W XMB 400W
Med
XLC 600W XMC 600W
XLD 750W XMD 750W
Xkite XKA 200W Xrite XRA 200W
Noise
Noise
Low
Med
Low
XKB 400W XRB 400W
XKC 600W XRC 600W
powerPacs (6slot package, 127mm wide)
Family MODEL Watts Family MODEL Watts
Xcite XCA 400W Xvite XVA 400W
Standard
XCB 700W XVB 700W
Med
XCC 1000W XVC 1000W
XCD 1200W XVD 1200W
XCE 1340W XVE 1340W
Temp
Xhite XHA 400W Xzite XZA 400W
High
Noise
Med
Low
XHB 600W XZB 900W
Xqite XQA 400W XZC 1200W
Noise
Low
XQB 900W
XQC 1200W
powerMods (for use with all powerPac models)
MODEL Vmin(4) Vnom Vmax(4) Imax Watts
Vtrim Vpot
Xg1 1.0 1.5 2.5 3.6 50A 125W
Xg2 1.5 3.2 5.0 6.0 40A 200W
c
Xg3 4.0 6.0 12.0 15.0 20A 240W erPa
Xg4 8.0 12.0 24.0 30.0 10A 240W
pow
Xg5 8.0 24.0 48.0 58.0 6A 288W
powerMod
Xg7 5.0 5.0 24.0 28.0 5A 120W s
Xg8 V1 5.0 5.0 24.0 28.0 3A 72W
V2 5.0 5.0 24.0 28.0 3A 72W
Part Numbering XVC 1 2 3 4 0 0 - 00 Factory Use
Configured Units may be specified and ordered using the part
numbering system shown opposite. For example, part number Sum of option
4 codes
XVC123400-00 specifies the following 1000W medical power supply.
Model `-' = standard;
· XVC-00 powerPac 1000W medically approved powerPac
`P' = preset
· Xg1 2.5V @ 50A powerMod Slot A
· Xg2 5V @ 40A powerMod
Slot B Slot F
· Xg3 12V @ 20A powerMod
· Xg4 24V @ 10A powerMod Slot C Slot E
Slot D
Accessories .
PowerMods can be parallel connected for higher current and series
connected for higher voltages. Configured units will have parallel and
series links fitted as required.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Slimline Plug & Play Power Supply Series 750W
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
lite
Slimline
Slimline Power Supply patents pending
User Configurable 1U size
The XLD is the latest addition to the Xlite family of power supplies and provides
an unprecedented 750W in a slimline 1U x 268 x 89mm package. Providing up to
PLUG & PLAY POWER 8 isolated outputs, the Xlite family is the most flexible power supply in its class
next generation power source and brings affordable configurable power to the 750W market.
With 800W peak power capability the slimline product boasts unrivalled power density
FEATURES saving valuable system space. Combine with ultra high efficiencies, the Xlite family
· Slimmest 750W configurable power provides system designers with flexible instant solutions that significantly shorten and
· Extra low profile: 1U height (40mm) simplify system design-in time.
· Up to 800W peak power
The XLD 750W powerPac model may be populated with up to 4 powerMods selected
· Ultra high efficiency, up to 89% from the table of powerMods shown below.
· Plug & Play Power
- allows fast custom configuration All configurations carry full safety agency approvals, UL60950, EN60950 and are CE
- allow easy logistics marked. For alternative power interfaces contact support@excelsys.com CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
· FLEXIMOUNT Flexible mounting system
· Few electrolytic capacitors (all long life)
powerMods powerPacs
· Visual LED indicators
MODEL Vmin(4) Vnom Vmax(4) Imax Watts MODEL Watts
· Series / Parallel of multiple outputs
Vtrim Vpot XLD 750W
· 5V bias standby voltage provided
Xg1 1.0 1.5 2.5 3.6 50A 125W
· Individual output control signals
Xg2 1.5 3.2 5.0 6.0 40A 200W
APPLICATIONS INCLUDE Xg3 4.0 6.0 12.0 15.0 20A 240W
· Industrial machines Xg4 8.0 12.0 24.0 30.0 10A 240W
· Test and measurement Xg5 8.0 24.0 48.0 58.0 6A 288W
· Automation equipment Xg7 5.0 5.0 24.0 28.0 5A 120W
· Printing
Xg8 V1 5.0 5.0 24.0 28.0 3A 72W
· Telecommunications V2 5.0 5.0 24.0 28.0 3A 72W
· For Medical applications see Xmite
EFFICIENCY (typical) MECHANICAL SPECIFICATIONS
93 1
92 Third angle projection
91
54.00 97.75
Efficiency %
90
122.00 92.00
89
J1
70C MAX OPERATING TEMPERATURE
SEE INSTRUCTION MANUAL
INPUT AC 100V-240V 50/60Hz
88 23.50
SLOT D
87
J2
SLOT C
86 42.00 TOP VIEW 19.00 89.00
SLOT B
85
23.50 SLOT A
84
70 85 100 115 130 145 160 175 190 205 220 235 260
Line Voltage VAC
40.40 29.50
All dimensions in mm.
Mounting Holes
4 M4 threaded holes on Base. Max screw penetration is 6mm from Base.
Series Fleximount Side Mounting Slots
Use with self-clinching studs type FH-M4-X or FH-832-X (X= stud length) from PEM, or equivalent
Alternatively, use Xgen Side Clamps from Excelsys. Part No. Z165 (drawing 61401)
750W Slimline Plug & Play Power Supply Series
SPECIFICATION applies to configured units consisting of powerMods modules plugged into the appropriate powerPac
INPUT
Parameter Conditions/Description Min Nom Max Units
Input Voltage Range Universal Input 85 264 VAC
120 380 VDC
Input Frequency Range 47 63 Hz
Slimline
Power Rating XLD Derate linearly from 750W at 140VAC to 525W at 85VAC. Note 5 750(800) W
Input Current XLD 85VAC in 525W out 7.5 A
Inrush Current 230VAC @ 25°C 50 A
Undervoltage Lockout Shutdown 65 74 VAC
Fusing XLD 250V 5 x 20mm F8A HRC
OUTPUT
Parameter Conditions/Description Min Nom Max Units
powerMod Power As per powerMod table
Output Adjustment Range Manual: Multi-turn potentiometer. As per powerMod table
Electronic: See Xgen Designers' Manual
Minimum Load 0 A
Line Regulation For ±10% change from nominal line ±0.1 %
Load Regulation For 25% to 75% load change ±0.2 %
Cross Regulation ±0.2 %
Transient Response For 25% to 75% load change Voltage Deviation 10 %
Settling Time 250 µs
Ripple and Noise 20MHz Bandwidth 1.0 % pk-pk
Overvoltage Protection Two-level. 1st level: Vset Tracking. 2nd level: Vmax (Latching) 110 125 %
Overcurrent Protection Straight line with hiccup activation at <30% of Vnom 110 120 %
See Designer's Manual for full details
Remote Sense Max. line drop compensation. (except Xg7, Xg8) 0.5 VDC
Overshoot 2 %
Turn-on Delay From AC In / Enable signal 1000/ 30 ms
Rise Time Monotonic 5 ms
Hold-up Time For nominal output voltages at full load 15 ms
Output Isolation Output to Output / Output to Chassis 500 / 500 VDC
GENERAL
Parameter Conditions/Description Min Nom Max Units
Isolation Voltage Input to Output 3000 VAC
Input to Chassis 1500 VAC
Efficiency 230VAC, 750W @ 24V 89 %
Safety Agency Approvals EN60950, UL60950, CSA22.2 No.950 UL File No. E181875
Leakage Current 250VAC, 60Hz, 25°C 1.5 mA
Signals See Xgen Series datasheet
Bias Supply Always ON. Current 250mA 4.8 5.0 5.2 VDC
Reliability Failures per million hours at 25°C and full load powerMod 0.98 fpmh
See Designers' Manual. powerPac excludes fans powerPac 0.92 fpmh
EMC
Parameter Standard Level Units
Emissions
Conducted EN55011, EN55022, FCC Level B
Radiated EN55011, EN55022, FCC Level B
Harmonic Distortion EN61000-3-2 Compliant
Flicker and Fluctuation EN61000-3-3 Compliant
Immunity
Electrostatic Discharge EN61000-4-2 Level 4
Radiated RFI EN61000-4-3 Level 3
Fast Transients - burst EN61000-4-4 Level 4
Input Line Surges EN61000-4-5 Class 4
Conducted RFI EN61000-4-6 10 V/m
Voltage Dips EN61000-4-11 (EN55024) 10 ms
ENVIRONMENTAL
Parameter Conditions/Description Min Nom Max Units
2 Operating Temperature -20 +70 °C
Storage Temperature -40 +85 °C
Derating 0.667% per °C 40-60°C.; 1.33% per per °C 60-70°C
Relative Humidity Non-condensing 5 95 %RH
Shock 3000 Bumps, 10G (16ms) half sine
Vibration 1.5G 10 200 Hz
NOTES 1. This product is not intended for use as a stand alone unit and must be installed by qualified personnel.
2. The specifications contained herein are believed to be correct at time of publication and are subject to change without notice.
3. All specifications at nominal input, full load, 25°C unless otherwise stated.
4. Vmin and Vmax voltages achieved when using Vtrim function on powerMod or the on board potentiometer. Vtrim is the lowest voltage that can be
achieved using Vtrim pin on powerMod. Vpot is the minimum voltage that can be achieved using the on-baord potentiometer. See Xgen series
Designers' Manual for full details on Vtrim and adjustment ranges.
5. 800W peak for 1s; Duty cycle 7%. powerMod output power must not exceed normal ratings.
6. When powering inductive or capacitive loads, it is recommended to use a blocking diode on the output.
Doc. XLD Rev02 11/09
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Xgen FLEXIBILITY and SIGNALS
Voltage Adjustment - Local Temperature Alarm (Option 01)
The multi-turn potentiometer that adjusts each output within the speci- Open collector signal indicating excessive powerPac temperatures due
fied range may be accessed via the output panel of the power supply. to fan failure or operation beyond ratings. This signal is activated at
Clockwise rotation increases output voltage. Resolution is approximate- least 10ms prior to system shutdown.
ly 5% of nominal voltage (Vnom) per turn.
Fan Fail (Option 01)
Voltage Adjustment - Remote (resistive / electronic) Open collector signal indicating that at least one of the system fans
The output voltage may be adjusted or trimmed by means of an exter- have failed. This does not cause system shutdown.
nal resistor or potentiometer network connected to the Vtrim pin. Linear
Electronic programming is also possible and may be implemented
according to the formula Vout = K Vcontrol. See Xgen series
Designers' Manual for full details.
Paralleling
To achieve increased current capacity, simply parallel outputs using the
standard parallel links. Excelsys `wireless' sharing ensures that current
hogging is not possible. To parallel connect outputs:
1. Switch on IShare switch to ON on powerMods.
2. Connect Negative parallel link.
3. Adjust output voltages of powerMods to within 5mV of eachother. Power Good
4. Connect Positive Parallel Link. Opto-isolated output signal indicates that the powerMod is operating
Parallel Links available to correctly and output voltage is within normal band.
order. Part Number XP1 Opto transistor ON = Good.
Seriesing
To achieve increased output voltages, simply series outputs using stan-
dard series links, paying attention to the requirements to maintain Indication LEDs
SELV levels if required in your system. Each powerMod has a visual indicator to identify that it is operating
Series Links available. Part within normal ratings. Very useful for system diagnosis.
Number XS1
Signal Connector Pinout
Pin J2 (powerPac) J3 (powerMod) J3 (powerMod)
Type A Type B)
Remote Sensing 1 common +sense +pg (V2)
2 +5V bias -sense -pg (V2)
When the load is remote from the power supply, the remote sense
pins may be used to compensate for drops in the power leads. 3 V trim inhibit (V2)
Where the power cabling contributes significant dynamic impedance, 4 ac fail I trim common (V2)
see Xgen series Designers' Manual. 5 fan fail* +inhibit/enable +pg (V1)
6 global enable -inhibit/enable -pg (V1)
Bias Voltage 7 temp alarm* +power good inhibit (V1)
A SELV isolated 5V (always on) bias voltage rated at 250mA is pro- 8 global inhibit -power good common (V1)
vided on J2 to facilitate miscellaneous control functions.
*Option 01 only
Current Limit Adjustment Signal Connector Pinout
The output current limit setting may be adjusted (downwards only) TYPE A Xg1-Xg7 TYPE B : Xg8
by means of an external resistor connection to the I trim pin.
Inhibit/Enable J3 J3
Inhibiting may be implemented either globally or on a per module Voltage V1 Adjust
3 Adjust
basis (powerPac or powerMod inhibiting). Reverse logic (Enabling)
V2 Adjust
may also be implemented, see Xgen series Designers' Manual. 2 1 2 1
J4
J4
AC Fail 4
Open collector signal indicating that the input voltage has failed or is 2
3
less than 80Vac. This signal changes state giving 5mS of warning
before loss of output regulation. See Xgen series Designers' Manual
2
for full specifications.
1
1
M4 Screws
J4 Connector : M4 Screw J4Connector : Camden 9200/4A
J3 Connector Mating Connector J3 Connector Mating Connector
Housing: Locking Molex 51110-0860 Housing: Locking Molex 51110-0860
Non Locking Molex 51110-0850 Non Locking Molex 51110-0850
Crimp Termnal: Molex p/n 50394 Crimp Termnal: Molex p/n 50394
See Xgen series Designers' Manual for full signal connector details.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Xgen Plug & Play Power Supply Series 200W to 1340W
Series
powerPacs (4slot package, 89mm wide)
Family MODEL Watts Family MODEL Watts
Xlite XLA 200W Xmite XMA 200W
Standard
XLB 400W XMB 400W
Med
XLC 600W XMC 600W
XLD 750W XMD 750W
Xkite XKA 200W Xrite XRA 200W
Noise
Noise
Low
Med
Low
XKB 400W XRB 400W
XKC 600W XRC 600W
powerPacs (6slot package, 127mm wide)
Family MODEL Watts Family MODEL Watts
Xcite XCA 400W Xvite XVA 400W
Standard
XCB 700W XVB 700W
Med
XCC 1000W XVC 1000W
XCD 1200W XVD 1200W
XCE 1340W XVE 1340W
Temp
Xhite XHA 400W Xzite XZA 400W
High
Noise
Med
Low
XHB 600W XZB 900W
Xqite XQA 400W XZC 1200W
Noise
Low
XQB 900W
XQC 1200W
powerMods (for use with all powerPac models)
MODEL Vmin(4) Vnom Vmax(4) Imax Watts
Vtrim Vpot
Xg1 1.0 1.5 2.5 3.6 50A 125W
Xg2 1.5 3.2 5.0 6.0 40A 200W
c
Xg3 4.0 6.0 12.0 15.0 20A 240W erPa
Xg4 8.0 12.0 24.0 30.0 10A 240W
pow
Xg5 8.0 24.0 48.0 58.0 6A 288W
powerMod
Xg7 5.0 5.0 24.0 28.0 5A 120W s
Xg8 V1 5.0 5.0 24.0 28.0 3A 72W
V2 5.0 5.0 24.0 28.0 3A 72W
Part Numbering XVC 1 2 3 4 0 0 - 00 Factory Use
Configured Units may be specified and ordered using the part
numbering system shown opposite. For example, part number Sum of option
4 codes
XVC123400-00 specifies the following 1000W medical power supply.
Model `-' = standard;
· XVC-00 powerPac 1000W medically approved powerPac
`P' = preset
· Xg1 2.5V @ 50A powerMod Slot A
· Xg2 5V @ 40A powerMod
Slot B Slot F
· Xg3 12V @ 20A powerMod
· Xg4 24V @ 10A powerMod Slot C Slot E
Slot D
Accessories .
PowerMods can be parallel connected for higher current and series
connected for higher voltages. Configured units will have parallel and
series links fitted as required.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
AC/DC Plug & Play Power Supply Series 400W-1200W
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
cite
Standard
AC/DC Power Supply patents pending
Ultra-high efficiency 1U size
The Xcite family of power supplies provides up to an incredible 1200W in an
extremely compact 1U x 260 x 127mm package. Boasting industry leading power
PLUG & PLAY POWER density of 15W/in3 and efficiencies of up to 90%, the Xcite family employs an
innovative plug & play architecture that allows users to instantly configure a
next generation power source custom power solution in less than 5 minutes!
FEATURES Ultra high efficiencies and high power density are made possible through the
combination of low loss technologies and the best field-proven technologies in planar
· 1.5V to 58V standard output voltages magnetics and surface mount electronics. Significantly increased efficiency reduces
· 1340W available (See XCE datasheet) system thermal load by more than 50%.
· All outputs fully floating
· Extra low profile: 1U height (40mm) The Xcite family consists of 4 powerPac models ranging in power levels from 400W to
1200W. Each model may be populated with up to 6 powerMods selected from the
· Ultra high efficiency, up to 90%
table of powerMods shown below.
· Plug & Play Power
- allows fast custom configuration All configurations carry full safety agency approvals, UL60950, EN60950 and are CE
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
- allow easy logistics marked. For alternative power interfaces contact support@excelsys.com Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
· Reduced system heat dissipation
powerMods powerPacs
· Few electrolytic capacitors (all long life)
MODEL Vmin Vnom Vmax Imax Watts MODEL Watts
· Visual LED indicators
· Series / Parallel of multiple outputs Xg1 1.5 2.5 3.6 50A 125W Xcite XCA 400W
· 5V bias standby voltage provided Xg2 3.2 5.0 6.0 40A 200W XCB 700W
· Individual output control signals Xg3 6.0 12.0 15.0 20A 240W XCC 1000W
Xg4 12.0 24.0 30.0 10A 240W XCD 1200W
APPLICATIONS INCLUDE
Xg5 28.0 48.0 58.0 6A 288W
· Industrial machines XCE 1340W
Xg7 5.0 24.0 28.0 5A 120W
· Test and measurement See XCEdatasheet
· Automation equipment Xg8 V1 5.0 24.0 28.0 3A 72W
V2 5.0 24.0 28.0 3A 72W
· Printing
· Telecommunications
· For Medical applications see Xvite
EFFICIENCY (typical) MECHANICAL SPECIFICATIONS
93 1
92 Third angle projection
91 50.00 97.75
Efficiency %
90
46.00 122.00 92.00
89
88 23.50
SLOT F
87 SLOT E
19.00
J1
70C MAX OPERATING TEMPERATURE
SEE INSTRUCTION MANUAL
INPUT AC 100V-240V 50/60Hz
86
TOP VIEW SLOT D
85 80.00 19.00 127.00
J2
SLOT C
84 19.00
70 85 100 115 130 145 160 175 190 205 220 235 260 SLOT B
Line Voltage VAC 23.50 SLOT A
40.40 29.50
All dimensions in mm.
Mounting Holes
4 M4 threaded holes on Base. Max screw penetration is 6mm from Base.
Series Fleximount Side Mounting Slots
Use with self-clinching studs type FH-M4-X or FH-832-X (X= stud length) from PEM, or equivalent
Alternatively, use Xgen Side Clamps from Excelsys. Part No. Z165 (drawing 61401)
400W-1200W AC/DC Plug & Play Power Supply Series
SPECIFICATION applies to configured units consisting of powerMods modules plugged into the appropriate powerPac
INPUT
Parameter Conditions/Description Min Nom Max Units
Input Voltage Range Universal Input 85 264 VAC
120 380 VDC
Input Frequency Range 47 63 Hz
Standard
Power Rating XCA 400 W
XCB 700 W
XCC Derate linearly from 1000W at 100VAC to 850W at 85VAC 1000 W
XCD Derate linearly from 1200W at 120VAC to 850W at 85VAC 1200 W
Input Current XCA 85VAC in 400W out 7.5 A
XCB 85VAC in 700W out 9.5 A
XCC, XCD 85VAC in 850W out 11.5 A
Inrush Current 230VAC @ 25°C 25 A
Undervoltage Lockout Shutdown 65 74 VAC
Fusing XCA 250V F8A HRC
XCB 250V F10A HRC
XCC, XCD 250V F12A HRC
OUTPUT
Parameter Conditions/Description Min Nom Max Units
powerMod Power As per powerMod table
Output Adjustment Range Manual: Multi-turn potentiometer. As per powerMod table
Electronic: See Xgen Designers' Manual
Minimum Load 0 A
Line Regulation For ±10% change from nominal line ±0.1 %
Load & Cross Regulation For 25% to 75% load change ±0.2 %
Transient Response For 25% to 75% load change Voltage Deviation 10 %
Settling Time 250 µs
Ripple and Noise 20MHz Bandwidth 1.0 % pk-pk
Overvoltage Protection 1st level: Vset Tracking. 2nd level: Vmax (Latching) 110 125 %
Overcurrent Protection Straight line with hiccup activation at <30% of Vnom 110 120 %.
See Designer's Manual for full details
Remote Sense Max. line drop compensation. (except Xg7, Xg8) 0.5 VDC
Overshoot 2 %
Turn-on Delay From AC In / Enable signal 600 / 30 ms
Rise Time Monotonic 5 ms
Hold-up Time For nominal output voltages at full load. XCA,XCB,XCC / XCD 20 / 15 ms
Output Isolation Output to Output / Output to Chassis 500 / 500 VDC
GENERAL
Parameter Conditions/Description Min Nom Max Units
Isolation Voltage Input to Output 3000 VAC
Input to Chassis 1500 VAC
Efficiency 230VAC, 1200W @ 24V 90 %
Safety Agency Approvals EN60950, UL60950, CSA22.2 No.950 UL File No. E181875
Leakage Current 250VAC, 60Hz, 25°C 1.5 mA
Signals See Xgen Series datasheet
Bias Supply Always ON. Current 250mA 4.8 5.0 5.2 VDC
Reliability Failures per million hours at 25°C and full load powerMod 0.98 fpmh
See Designers' Manual. powerPac excludes fans powerPac 0.92 fpmh
EMC
Parameter Standard Level Units
Emissions
Conducted EN55011, EN55022, FCC Level B
Radiated EN55011, EN55022, FCC Level B
Harmonic Distortion EN61000-3-2 Compliant
Flicker and Fluctuation EN61000-3-3 Compliant
Immunity
Electrostatic Discharge EN61000-4-2 Level 4
Radiated RFI EN61000-4-3 Level 3
Fast Transients - burst EN61000-4-4 Level 4
2 Input Line Surges EN61000-4-5 Class 4
Conducted RFI EN61000-4-6 10 V/m
Voltage Dips EN61000-4-11 (EN55024) 10 ms
ENVIRONMENTAL
Parameter Conditions/Description Min Nom Max Units
Operating Temperature -20 +70 °C
Storage Temperature -40 +85 °C
Derating 1.6% per °C above 40°C. See Designers Manual for full deratings
Relative Humidity Non-condensing 5 95 %RH
Shock 3000 Bumps, 10G (16ms) half sine
Vibration 1.5G 10 200 Hz
NOTES 1. This product is not intended for use as a stand alone unit and must be installed by qualified personnel.
2. The specifications contained herein are believed to be correct at time of publication and are subject to change without notice.
3. All specifications at nominal input, full load, 25°C unless otherwise stated.
4. When powering inductive or capacitive loads, it is recommended to use a blocking diode on the output. Doc. 40032 rev. 08 11/09
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Xgen FLEXIBILITY and SIGNALS
Voltage Adjustment - Local Temperature Alarm (Option 01)
The multi-turn potentiometer that adjusts each output within the speci- Open collector signal indicating excessive powerPac temperatures due
fied range may be accessed via the output panel of the power supply. to fan failure or operation beyond ratings. This signal is activated at
Clockwise rotation increases output voltage. Resolution is approximate- least 10ms prior to system shutdown.
ly 5% of nominal voltage (Vnom) per turn.
Fan Fail (Option 01)
Voltage Adjustment - Remote (resistive / electronic) Open collector signal indicating that at least one of the system fans
The output voltage may be adjusted or trimmed by means of an exter- have failed. This does not cause system shutdown.
nal resistor or potentiometer network connected to the Vtrim pin. Linear
Electronic programming is also possible and may be implemented
according to the formula Vout = K Vcontrol. See Xgen series
Designers' Manual for full details.
Paralleling
To achieve increased current capacity, simply parallel outputs using the
standard parallel links. Excelsys `wireless' sharing ensures that current
hogging is not possible. To parallel connect outputs:
1. Switch on IShare switch to ON on powerMods.
2. Connect Negative parallel link.
3. Adjust output voltages of powerMods to within 5mV of eachother. Power Good
4. Connect Positive Parallel Link. Opto-isolated output signal indicates that the powerMod is operating
Parallel Links available to correctly and output voltage is within normal band.
order. Part Number XP1 Opto transistor ON = Good.
Seriesing
To achieve increased output voltages, simply series outputs using stan-
dard series links, paying attention to the requirements to maintain Indication LEDs
SELV levels if required in your system. Each powerMod has a visual indicator to identify that it is operating
Series Links available. Part within normal ratings. Very useful for system diagnosis.
Number XS1
Signal Connector Pinout
Pin J2 (powerPac) J3 (powerMod) J3 (powerMod)
Type A Type B)
Remote Sensing 1 common +sense +pg (V2)
2 +5V bias -sense -pg (V2)
When the load is remote from the power supply, the remote sense
pins may be used to compensate for drops in the power leads. 3 V trim inhibit (V2)
Where the power cabling contributes significant dynamic impedance, 4 ac fail I trim common (V2)
see Xgen series Designers' Manual. 5 fan fail* +inhibit/enable +pg (V1)
6 global enable -inhibit/enable -pg (V1)
Bias Voltage 7 temp alarm* +power good inhibit (V1)
A SELV isolated 5V (always on) bias voltage rated at 250mA is pro- 8 global inhibit -power good common (V1)
vided on J2 to facilitate miscellaneous control functions.
*Option 01 only
Current Limit Adjustment Signal Connector Pinout
The output current limit setting may be adjusted (downwards only) TYPE A Xg1-Xg7 TYPE B : Xg8
by means of an external resistor connection to the I trim pin.
Inhibit/Enable J3 J3
Inhibiting may be implemented either globally or on a per module Voltage V1 Adjust
3 Adjust
basis (powerPac or powerMod inhibiting). Reverse logic (Enabling)
V2 Adjust
may also be implemented, see Xgen series Designers' Manual. 2 1 2 1
J4
J4
AC Fail 4
Open collector signal indicating that the input voltage has failed or is 2
3
less than 80Vac. This signal changes state giving 5mS of warning
before loss of output regulation. See Xgen series Designers' Manual
2
for full specifications.
1
1
M4 Screws
J4 Connector : M4 Screw J4Connector : Camden 9200/4A
J3 Connector Mating Connector J3 Connector Mating Connector
Housing: Locking Molex 51110-0860 Housing: Locking Molex 51110-0860
Non Locking Molex 51110-0850 Non Locking Molex 51110-0850
Crimp Termnal: Molex p/n 50394 Crimp Termnal: Molex p/n 50394
See Xgen series Designers' Manual for full signal connector details.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Xgen Plug & Play Power Supply Series 200W to 1340W
Series
powerPacs (4slot package, 89mm wide)
Family MODEL Watts Family MODEL Watts
Xlite XLA 200W Xmite XMA 200W
Standard
XLB 400W XMB 400W
Med
XLC 600W XMC 600W
XLD 750W XMD 750W
Xkite XKA 200W Xrite XRA 200W
Noise
Noise
Low
Med
Low
XKB 400W XRB 400W
XKC 600W XRC 600W
powerPacs (6slot package, 127mm wide)
Family MODEL Watts Family MODEL Watts
Xcite XCA 400W Xvite XVA 400W
Standard
XCB 700W XVB 700W
Med
XCC 1000W XVC 1000W
XCD 1200W XVD 1200W
XCE 1340W XVE 1340W
Temp
Xhite XHA 400W Xzite XZA 400W
High
Noise
Med
Low
XHB 600W XZB 900W
Xqite XQA 400W XZC 1200W
Noise
Low
XQB 900W
XQC 1200W
powerMods (for use with all powerPac models)
MODEL Vmin(4) Vnom Vmax(4) Imax Watts
Vtrim Vpot
Xg1 1.0 1.5 2.5 3.6 50A 125W
Xg2 1.5 3.2 5.0 6.0 40A 200W
c
Xg3 4.0 6.0 12.0 15.0 20A 240W erPa
Xg4 8.0 12.0 24.0 30.0 10A 240W
pow
Xg5 8.0 24.0 48.0 58.0 6A 288W
powerMod
Xg7 5.0 5.0 24.0 28.0 5A 120W s
Xg8 V1 5.0 5.0 24.0 28.0 3A 72W
V2 5.0 5.0 24.0 28.0 3A 72W
Part Numbering XVC 1 2 3 4 0 0 - 00 Factory Use
Configured Units may be specified and ordered using the part
numbering system shown opposite. For example, part number Sum of option
4 codes
XVC123400-00 specifies the following 1000W medical power supply.
Model `-' = standard;
· XVC-00 powerPac 1000W medically approved powerPac
`P' = preset
· Xg1 2.5V @ 50A powerMod Slot A
· Xg2 5V @ 40A powerMod
Slot B Slot F
· Xg3 12V @ 20A powerMod
· Xg4 24V @ 10A powerMod Slot C Slot E
Slot D
Accessories .
PowerMods can be parallel connected for higher current and series
connected for higher voltages. Configured units will have parallel and
series links fitted as required.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
AC/DC Plug & Play Power Supply Series 1340W
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
cite
Standard
XCE AC/DC Power Supply patents pending
Ultra-high efficiency 1U size
The XCE addition to the Xgen family of power supplies provides up to an
incredible 1340W (peak power of 1450W) in an extremely compact 1U x 268 x
PLUG & PLAY POWER 127mm package. Boasting an industry leading power density of 17W/in3 and
efficiencies of up to 90%, the XCE family employs the innovative Xgen plug &
next generation power source play architecture that allows users to instantly configure a custom power
solution in less than 5 minutes!
FEATURES
Ultra high efficiencies and high power density are made possible through the
· 1.5V to 58V standard output voltages combination of low loss technologies and the best field-proven technologies in planar
· All outputs fully floating magnetics and surface mount electronics. Significantly increased efficiency reduces
· Extra low profile: 1U height (40mm) system thermal load by more than 50%.
· Ultra high efficiency, up to 90%
The XCE can be populated with up to 6 powerMods selected from the table of
· Plug & Play Power
powerMods shown below.
- allows fast custom configuration
· Up to 1450W peak power for 10 sec All configurations carry full safety agency approvals, UL60950, EN60950 and are CE
· Reduced system heat dissipation marked. For alternative power interfaces contact support@excelsys.com CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
· Few electrolytic capacitors (all long life)
powerMods powerPacs
· Visual LED indicators
MODEL Vmin Vnom Vmax Imax Watts MODEL Watts
· Series / Parallel of multiple outputs
· 5V bias standby voltage provided Xg1 1.5 2.5 3.6 50A 125W XCE 1340W
· Individual output control signals Xg2 3.2 5.0 6.0 40A 200W
Xg3 6.0 12.0 15.0 20A 240W
APPLICATIONS INCLUDE Xg4 12.0 24.0 30.0 10A 240W
· Industrial machines Xg5 28.0 48.0 58.0 6A 288W
· Test and measurement
Xg7 5.0 24.0 28.0 5A 120W
· Automation equipment
Xg8 V1 5.0 24.0 28.0 3A 72W
· Printing
V2 5.0 24.0 28.0 3A 72W
· Telecommunications
· For Medical applications see XVE
EFFICIENCY (typical) MECHANICAL SPECIFICATIONS
93 1
Third angle projection
92
91 54.00 97.75
Efficiency %
90 122.00 92.00
89
23.50 SLOT F
88
87 SLOT E
19.00
J1
70C MAX OPERATING TEMPERATURE
SEE INSTRUCTION MANUAL
INPUT AC 100V-240V 50/60Hz
86 TOP VIEW SLOT D
80.00 19.00 127.00
85 SLOT C
J2
19.00
84
SLOT B
70 85 100 115 130 145 160 175 190 205 220 235 260
SLOT A
Line Voltage VAC 23.50
40.40 29.50
All dimensions in mm.
Mounting Holes
4 M4 threaded holes on Base. Max screw penetration is 6mm from Base.
Series Fleximount Side Mounting Slots
Use with self-clinching studs type FH-M4-X or FH-832-X (X= stud length) from PEM, or equivalent
Alternatively, use Xgen Side Clamps from Excelsys. Part No. Z165 (drawing 61401)
1340W AC/DC Plug & Play Power Supply Series
SPECIFICATION applies to configured units consisting of powerMods modules plugged into the appropriate powerPac
INPUT
Parameter Conditions/Description Min Nom Max Units
Input Voltage Range Universal Input 85 264 VAC
120 380 VDC
Input Frequency Range 47 63 Hz
Standard
Power Rating XCE See Xgen Designers' Manual for derating versus input line voltage 1340 (1450) W
Input Current XCE 85VAC in 1000W out 14.0 A
Inrush Current 230VAC @ 25°C 25 A
Undervoltage Lockout Shutdown 65 74 VAC
Fusing XCE 250V F15A HRC Conditions
OUTPUT
Parameter Conditions/Description Min Nom Max Units
powerMod Power As per powerMod table
Output Adjustment Range Manual: Multi-turn potentiometer. As per powerMod table
Electronic: See Xgen Designers' Manual
Minimum Load 0 A
Line Regulation For ±10% change from nominal line ±0.1 %
Load & Cross Regulation For 25% to 75% load change ±0.2 %
Transient Response For 25% to 75% load change Voltage Deviation 10 %
Settling Time 250 µs
Ripple and Noise 20MHz Bandwidth 1.0 % pk-pk
Overvoltage Protection 1st level: Vset Tracking. 2nd level: Vmax (Latching) 110 125 %
Overcurrent Protection Straight line with hiccup activation at <30% of Vnom 110 120 %.
See Designer's Manual for full details
Remote Sense Max. line drop compensation. (except Xg7, Xg8) 0.5 VDC
Overshoot 2 %
Turn-on Delay From AC In / Enable signal 700 / 30 ms
Rise Time Monotonic 5 ms
Hold-up Time For nominal output voltages at full load. 230VAC/115VAC 15 ms
Output Isolation Output to Output / Output to Chassis 500 / 500 VDC
GENERAL
Parameter Conditions/Description Min Nom Max Units
Isolation Voltage Input to Output 3000 VAC
Input to Chassis 1500 VAC
Efficiency 230VAC, 1340W @ 24V 90 %
Safety Agency Approvals EN60950, UL60950, CSA22.2 No.950 UL File No. E181875
Leakage Current 250VAC, 60Hz, 25°C 1.5 mA
Signals See Xgen Series datasheet
Bias Supply Always ON. Current 30mA 4.8 5.0 5.2 VDC
Reliability Failures per million hours at 25°C and full load powerMod 0.98 fpmh
See Designers' Manual. powerPac excludes fans powerPac 0.92 fpmh
EMC
Parameter Standard Level Units
Emissions
Conducted EN55011, EN55022, FCC Level B
Radiated EN55011, EN55022, FCC Level B
Harmonic Distortion EN61000-3-2 Compliant
Flicker and Fluctuation EN61000-3-3 Compliant
Immunity
Electrostatic Discharge EN61000-4-2 Level 4
Radiated RFI EN61000-4-3 Level 3
Fast Transients - burst EN61000-4-4 Level 4
Input Line Surges EN61000-4-5 Class 4
Conducted RFI EN61000-4-6 10 V/m
Voltage Dips EN61000-4-11 (EN55024) 10 ms
ENVIRONMENTAL
Parameter Conditions/Description Min Nom Max Units
Operating Temperature -20 +70 °C
2 Storage Temperature -40 +85 °C
Derating See Xgen Designers Manual for full deratings versus temperature
Relative Humidity Non-condensing 5 95 %RH
Shock 3000 Bumps, 10G (16ms) half sine
Vibration 1.5G 10 200 Hz
NOTES 1. This product is not intended for use as a stand alone unit and must be installed by qualified personnel.
2. The specifications contained herein are believed to be correct at time of publication and are subject to change without notice.
3. All specifications at nominal input, full load, 25°C unless otherwise stated.
4. 1450W peak for 10s. Duty Cycle 8%. powerMod output power must not exceed normal ratings.
5. When powering inductive or capacitive loads, it is recommended to use a blocking diode on the output.
XCE Rev 03 11/09
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Xgen FLEXIBILITY and SIGNALS
Voltage Adjustment - Local Temperature Alarm (Option 01)
The multi-turn potentiometer that adjusts each output within the speci- Open collector signal indicating excessive powerPac temperatures due
fied range may be accessed via the output panel of the power supply. to fan failure or operation beyond ratings. This signal is activated at
Clockwise rotation increases output voltage. Resolution is approximate- least 10ms prior to system shutdown.
ly 5% of nominal voltage (Vnom) per turn.
Fan Fail (Option 01)
Voltage Adjustment - Remote (resistive / electronic) Open collector signal indicating that at least one of the system fans
The output voltage may be adjusted or trimmed by means of an exter- have failed. This does not cause system shutdown.
nal resistor or potentiometer network connected to the Vtrim pin. Linear
Electronic programming is also possible and may be implemented
according to the formula Vout = K Vcontrol. See Xgen series
Designers' Manual for full details.
Paralleling
To achieve increased current capacity, simply parallel outputs using the
standard parallel links. Excelsys `wireless' sharing ensures that current
hogging is not possible. To parallel connect outputs:
1. Switch on IShare switch to ON on powerMods.
2. Connect Negative parallel link.
3. Adjust output voltages of powerMods to within 5mV of eachother. Power Good
4. Connect Positive Parallel Link. Opto-isolated output signal indicates that the powerMod is operating
Parallel Links available to correctly and output voltage is within normal band.
order. Part Number XP1 Opto transistor ON = Good.
Seriesing
To achieve increased output voltages, simply series outputs using stan-
dard series links, paying attention to the requirements to maintain Indication LEDs
SELV levels if required in your system. Each powerMod has a visual indicator to identify that it is operating
Series Links available. Part within normal ratings. Very useful for system diagnosis.
Number XS1
Signal Connector Pinout
Pin J2 (powerPac) J3 (powerMod) J3 (powerMod)
Type A Type B)
Remote Sensing 1 common +sense +pg (V2)
2 +5V bias -sense -pg (V2)
When the load is remote from the power supply, the remote sense
pins may be used to compensate for drops in the power leads. 3 V trim inhibit (V2)
Where the power cabling contributes significant dynamic impedance, 4 ac fail I trim common (V2)
see Xgen series Designers' Manual. 5 fan fail* +inhibit/enable +pg (V1)
6 global enable -inhibit/enable -pg (V1)
Bias Voltage 7 temp alarm* +power good inhibit (V1)
A SELV isolated 5V (always on) bias voltage rated at 250mA is pro- 8 global inhibit -power good common (V1)
vided on J2 to facilitate miscellaneous control functions.
*Option 01 only
Current Limit Adjustment Signal Connector Pinout
The output current limit setting may be adjusted (downwards only) TYPE A Xg1-Xg7 TYPE B : Xg8
by means of an external resistor connection to the I trim pin.
Inhibit/Enable J3 J3
Inhibiting may be implemented either globally or on a per module Voltage V1 Adjust
3 Adjust
basis (powerPac or powerMod inhibiting). Reverse logic (Enabling)
V2 Adjust
may also be implemented, see Xgen series Designers' Manual. 2 1 2 1
J4
J4
AC Fail 4
Open collector signal indicating that the input voltage has failed or is 2
3
less than 80Vac. This signal changes state giving 5mS of warning
before loss of output regulation. See Xgen series Designers' Manual
2
for full specifications.
1
1
M4 Screws
J4 Connector : M4 Screw J4Connector : Camden 9200/4A
J3 Connector Mating Connector J3 Connector Mating Connector
Housing: Locking Molex 51110-0860 Housing: Locking Molex 51110-0860
Non Locking Molex 51110-0850 Non Locking Molex 51110-0850
Crimp Termnal: Molex p/n 50394 Crimp Termnal: Molex p/n 50394
See Xgen series Designers' Manual for full signal connector details.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Xgen Plug & Play Power Supply Series 200W to 1340W
Series
powerPacs (4slot package, 89mm wide)
Family MODEL Watts Family MODEL Watts
Xlite XLA 200W Xmite XMA 200W
Standard
XLB 400W XMB 400W
Med
XLC 600W XMC 600W
XLD 750W XMD 750W
Xkite XKA 200W Xrite XRA 200W
Noise
Noise
Low
Med
Low
XKB 400W XRB 400W
XKC 600W XRC 600W
powerPacs (6slot package, 127mm wide)
Family MODEL Watts Family MODEL Watts
Xcite XCA 400W Xvite XVA 400W
Standard
XCB 700W XVB 700W
Med
XCC 1000W XVC 1000W
XCD 1200W XVD 1200W
XCE 1340W XVE 1340W
Temp
Xhite XHA 400W Xzite XZA 400W
High
Noise
Med
Low
XHB 600W XZB 900W
Xqite XQA 400W XZC 1200W
Noise
Low
XQB 900W
XQC 1200W
powerMods (for use with all powerPac models)
MODEL Vmin(4) Vnom Vmax(4) Imax Watts
Vtrim Vpot
Xg1 1.0 1.5 2.5 3.6 50A 125W
Xg2 1.5 3.2 5.0 6.0 40A 200W
c
Xg3 4.0 6.0 12.0 15.0 20A 240W erPa
Xg4 8.0 12.0 24.0 30.0 10A 240W
pow
Xg5 8.0 24.0 48.0 58.0 6A 288W
powerMod
Xg7 5.0 5.0 24.0 28.0 5A 120W s
Xg8 V1 5.0 5.0 24.0 28.0 3A 72W
V2 5.0 5.0 24.0 28.0 3A 72W
Part Numbering XVC 1 2 3 4 0 0 - 00 Factory Use
Configured Units may be specified and ordered using the part
numbering system shown opposite. For example, part number Sum of option
4 codes
XVC123400-00 specifies the following 1000W medical power supply.
Model `-' = standard;
· XVC-00 powerPac 1000W medically approved powerPac
`P' = preset
· Xg1 2.5V @ 50A powerMod Slot A
· Xg2 5V @ 40A powerMod
Slot B Slot F
· Xg3 12V @ 20A powerMod
· Xg4 24V @ 10A powerMod Slot C Slot E
Slot D
Accessories .
PowerMods can be parallel connected for higher current and series
connected for higher voltages. Configured units will have parallel and
series links fitted as required.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Slimline Medically Approved Power Supply 200W/400W/600W
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
mite
Slimline
Medical
Medical Power Supply patents pending
User Configurable 1U size
The Xmite family of medically approved power supplies provides up to 600W in a
PLUG & PLAY POWER slimline 1U x 260 x 89mm package. The Xmite family carries full safety agency
next generation power source approvals to EN60601-1 and UL2601-1, meeting the stringent creepage
requirements in this compact package. Providing up to 8 isolated outputs, the
Xmite family is the most flexible power supply in its class and brings affordable
FEATURES configurable power to the 200-600W medical market.
· EN60601-1 and UL2601-1 approved
The Xmite family consists of 3 powerPac models in 200W, 400W and 600W power
· Less than 300µA leakage current levels. Each powerPac model may be populated with up to 4 powerMods selected
· 4000VAC isolation from the table of powerMods shown below. Simply select your appropriate powerPac
· Slimmest 600W configurable power and powerMods to get your instant custom power solution.
· 750W available (See XMD datasheet)
This slimline product boasts unrivalled power density, providing significant system space
· Extra low profile: 1U height (40mm)
savings. Combined with ultra-high efficiencies, the Xmite family provides system
· Ultra high efficiency, up to 89% designers with flexible instant solutions that significantly shorten system design-in time.
· Plug & Play Power For alternative power interfaces contact support@excelsys.com CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
- allows fast custom configuration
powerMods powerPacs
- allow easy logistics
MODEL Vmin Vnom Vmax Imax Watts MODEL Watts
· FLEXIMOUNT Flexible mounting system
· Few electrolytic capacitors (all long life) Xg1 1.5 2.5 3.6 50A 125W XMA 200W
Xmite
· Series / Parallel of multiple outputs Xg2 3.2 5.0 6.0 40A 200W XMB 400W
· 5V bias standby voltage provided Xg3 6.0 12.0 15.0 20A 240W
XMC 600W
· Individual output control signals Xg4 12.0 24.0 30.0 10A 240W
Xg5 28.0 48.0 58.0 6A 288W XMD 750W
APPLICATIONS INCLUDE See XMD datasheet
Xg7 5.0 24.0 28.0 5A 120W
· Radiological imaging
Xg8 V1 5.0 24.0 28.0 3A 72W
· Clinical diagnostics
V2 5.0 24.0 28.0 3A 72W
· Medical lasers
· Clinical chemistry
· For non-medical applications see Xlite
EFFICIENCY (typical) MECHANICAL SPECIFICATIONS
93 1
92 Third angle projection
91 50.00 97.75
Efficiency %
90
46.00 122.00 92.00
89
J1
70C MAX OPERATING TEMPERATURE
SEE INSTRUCTION MANUAL
INPUT AC 100V-240V 50/60Hz
88 23.50
SLOT D
87
J2
SLOT C
42.00 19.00 89.00
86 TOP VIEW
SLOT B
85
23.50 SLOT A
84
70 85 100 115 130 145 160 175 190 205 220 235 260
Line Voltage VAC
40.40 29.50
All dimensions in mm.
Mounting Holes
4 M4 threaded holes on Base. Max screw penetration is 6mm from Base.
Series Fleximount Side Mounting Slots
Use with self-clinching studs type FH-M4-X or FH-832-X (X= stud length) from PEM, or equivalent
Alternatively, use Xgen Side Clamps from Excelsys. Part No. Z165 (drawing 61401)
200W/400W/600W Slimline Medically Approved Power Supply
SPECIFICATION applies to configured units consisting of powerMods modules plugged into the appropriate powerPac
INPUT
Parameter Conditions/Description Min Nom Max Units
Input Voltage Range Universal Input 85 264 VAC
120 380 VDC
Input Frequency Range 47 63 Hz
Slimline
Power Rating XMA 200 W
XMB 400 W
XMC Derate linearly from 600W at 180VAC to 400W at 85VAC 600 W
Input Current XMA 85VAC in 200W out 4.0 A
XMB 85VAC in 400W out 6.0 A
XMC 85VAC in 400W out 7.5 A
Inrush Current 230VAC @ 25°C 50 A
Undervoltage Lockout Shutdown 65 74 VAC
Fusing XMA 250V 5 x 20mm F5A HRC
XMB 250V 5 x 20mm F6.3A HRC
XMC 250V 5 x 20mm F8A HRC
OUTPUT
Parameter Conditions/Description Min Nom Max Units
powerMod Power As per powerMod table
Output Adjustment Range Manual: Multi-turn potentiometer. As per powerMod table
Electronic: See Xgen Designers' Manual
Minimum Load 0 A
Line Regulation For ±10% change from nominal line ±0.1 %
Load Regulation For 25% to 75% load change ±0.2 %
Cross Regulation ±0.2 %
Transient Response For 25% to 75% load change Voltage Deviation 10 %
Settling Time 250 µs
Ripple and Noise 20MHz Bandwidth 1.0 % pk-pk
Overvoltage Protection 1st level: Vset Tracking. 2nd level: Vmax (Latching) 110 125 %
Overcurrent Protection Straight line with hiccup activation at <30% of Vnom 110 120 %
See Designer's Manual for full details
Remote Sense Max. line drop compensation. (except Xg7, Xg8) 0.5 VDC
Overshoot 2 %
Turn-on Delay From AC In / Enable signal 600 / 30 ms
Rise Time Monotonic 5 ms
Hold-up Time For nominal output voltages at full load 20 ms
Output Isolation Output to Output / Output to Chassis 500 / 500 VDC
GENERAL
Parameter Conditions/Description Min Nom Max Units
Isolation Voltage Input to Output 4000 VAC
Input to Chassis 1500 VAC
Efficiency 230VAC, 400W @ 24V 89 %
Safety Agency Approvals EN60601-1, UL2601-1, CSA601-1 UL File No. E230761
Leakage Current 250VAC, 60Hz, 25°C 300 µA
Signals See Xgen Series datasheet
Bias Supply Always ON. Current 250mA 4.8 5.0 5.2 VDC
Reliability Failures per million hours at 25°C and full load powerMod 0.98 fpmh
See Designers' Manual. powerPac excludes fans powerPac 0.92 fpmh
EMC
Parameter Standard Level Units
Emissions
Conducted EN55011, EN55022, FCC Level B
Radiated EN55011, EN55022, FCC Level B
Harmonic Distortion EN61000-3-2 Compliant
Flicker and Fluctuation EN61000-3-3 Compliant
Immunity
Electrostatic Discharge EN61000-4-2 Level 4
Radiated RFI EN61000-4-3 Level 3
Fast Transients - burst EN61000-4-4 Level 4
2 Input Line Surges EN61000-4-5 Class 4
Conducted RFI EN61000-4-6 10 V/m
Voltage Dips EN61000-4-11 (EN55024) 10 ms
ENVIRONMENTAL
Parameter Conditions/Description Min Nom Max Units
Operating Temperature -20 +70 °C
Storage Temperature -40 +85 °C
Derating 2.5% per °C above 40°C. See Designers Manual for full deratings
Relative Humidity Non-condensing 5 95 %RH
Shock 3000 Bumps, 10G (16ms) half sine
Vibration 1.5G 10 200 Hz
NOTES 1. This product is not intended for use as a stand alone unit and must be installed by qualified personnel.
2. The specifications contained herein are believed to be correct at time of publication and are subject to change without notice.
3. All specifications at nominal input, full load, 25°C unless otherwise stated.
4. When powering inductive or capacitive loads, it is recommended to use a blocking diode on the output. Doc. 40040 rev. 08 11/09
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Xgen FLEXIBILITY and SIGNALS
Voltage Adjustment - Local Temperature Alarm (Option 01)
The multi-turn potentiometer that adjusts each output within the speci- Open collector signal indicating excessive powerPac temperatures due
fied range may be accessed via the output panel of the power supply. to fan failure or operation beyond ratings. This signal is activated at
Clockwise rotation increases output voltage. Resolution is approximate- least 10ms prior to system shutdown.
ly 5% of nominal voltage (Vnom) per turn.
Fan Fail (Option 01)
Voltage Adjustment - Remote (resistive / electronic) Open collector signal indicating that at least one of the system fans
The output voltage may be adjusted or trimmed by means of an exter- have failed. This does not cause system shutdown.
nal resistor or potentiometer network connected to the Vtrim pin. Linear
Electronic programming is also possible and may be implemented
according to the formula Vout = K Vcontrol. See Xgen series
Designers' Manual for full details.
Paralleling
To achieve increased current capacity, simply parallel outputs using the
standard parallel links. Excelsys `wireless' sharing ensures that current
hogging is not possible. To parallel connect outputs:
1. Switch on IShare switch to ON on powerMods.
2. Connect Negative parallel link.
3. Adjust output voltages of powerMods to within 5mV of eachother. Power Good
4. Connect Positive Parallel Link. Opto-isolated output signal indicates that the powerMod is operating
Parallel Links available to correctly and output voltage is within normal band.
order. Part Number XP1 Opto transistor ON = Good.
Seriesing
To achieve increased output voltages, simply series outputs using stan-
dard series links, paying attention to the requirements to maintain Indication LEDs
SELV levels if required in your system. Each powerMod has a visual indicator to identify that it is operating
Series Links available. Part within normal ratings. Very useful for system diagnosis.
Number XS1
Signal Connector Pinout
Pin J2 (powerPac) J3 (powerMod) J3 (powerMod)
Type A Type B)
Remote Sensing 1 common +sense +pg (V2)
2 +5V bias -sense -pg (V2)
When the load is remote from the power supply, the remote sense
pins may be used to compensate for drops in the power leads. 3 V trim inhibit (V2)
Where the power cabling contributes significant dynamic impedance, 4 ac fail I trim common (V2)
see Xgen series Designers' Manual. 5 fan fail* +inhibit/enable +pg (V1)
6 global enable -inhibit/enable -pg (V1)
Bias Voltage 7 temp alarm* +power good inhibit (V1)
A SELV isolated 5V (always on) bias voltage rated at 250mA is pro- 8 global inhibit -power good common (V1)
vided on J2 to facilitate miscellaneous control functions.
*Option 01 only
Current Limit Adjustment Signal Connector Pinout
The output current limit setting may be adjusted (downwards only) TYPE A Xg1-Xg7 TYPE B : Xg8
by means of an external resistor connection to the I trim pin.
Inhibit/Enable J3 J3
Inhibiting may be implemented either globally or on a per module Voltage V1 Adjust
3 Adjust
basis (powerPac or powerMod inhibiting). Reverse logic (Enabling)
V2 Adjust
may also be implemented, see Xgen series Designers' Manual. 2 1 2 1
J4
J4
AC Fail 4
Open collector signal indicating that the input voltage has failed or is 2
3
less than 80Vac. This signal changes state giving 5mS of warning
before loss of output regulation. See Xgen series Designers' Manual for
2
full specifications.
1
1
M4 Screws
J4 Connector : M4 Screw J4Connector : Camden 9200/4A
J3 Connector Mating Connector J3 Connector Mating Connector
Housing: Locking Molex 51110-0860 Housing: Locking Molex 51110-0860
Non Locking Molex 51110-0850 Non Locking Molex 51110-0850
Crimp Termnal: Molex p/n 50394 Crimp Termnal: Molex p/n 50394
See Xgen series Designers' Manual for full signal connector details.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Xgen Plug & Play Power Supply Series 200W to 1340W
Series
powerPacs (4slot package, 89mm wide)
Family MODEL Watts Family MODEL Watts
Xlite XLA 200W Xmite XMA 200W
Standard
XLB 400W XMB 400W
Med
XLC 600W XMC 600W
XLD 750W XMD 750W
Xkite XKA 200W Xrite XRA 200W
Noise
Noise
Low
Med
Low
XKB 400W XRB 400W
XKC 600W XRC 600W
powerPacs (6slot package, 127mm wide)
Family MODEL Watts Family MODEL Watts
Xcite XCA 400W Xvite XVA 400W
Standard
XCB 700W XVB 700W
Med
XCC 1000W XVC 1000W
XCD 1200W XVD 1200W
XCE 1340W XVE 1340W
Temp
Xhite XHA 400W Xzite XZA 400W
High
Noise
Med
Low
XHB 600W XZB 900W
Xqite XQA 400W XZC 1200W
Noise
Low
XQB 900W
XQC 1200W
powerMods (for use with all powerPac models)
MODEL Vmin(4) Vnom Vmax(4) Imax Watts
Vtrim Vpot
Xg1 1.0 1.5 2.5 3.6 50A 125W
Xg2 1.5 3.2 5.0 6.0 40A 200W
c
Xg3 4.0 6.0 12.0 15.0 20A 240W erPa
Xg4 8.0 12.0 24.0 30.0 10A 240W
pow
Xg5 8.0 24.0 48.0 58.0 6A 288W
powerMod
Xg7 5.0 5.0 24.0 28.0 5A 120W s
Xg8 V1 5.0 5.0 24.0 28.0 3A 72W
V2 5.0 5.0 24.0 28.0 3A 72W
Part Numbering XVC 1 2 3 4 0 0 - 00 Factory Use
Configured Units may be specified and ordered using the part
numbering system shown opposite. For example, part number Sum of option
4 codes
XVC123400-00 specifies the following 1000W medical power supply.
Model `-' = standard;
· XVC-00 powerPac 1000W medically approved powerPac
`P' = preset
· Xg1 2.5V @ 50A powerMod Slot A
· Xg2 5V @ 40A powerMod
Slot B Slot F
· Xg3 12V @ 20A powerMod
· Xg4 24V @ 10A powerMod Slot C Slot E
Slot D
Accessories .
PowerMods can be parallel connected for higher current and series
connected for higher voltages. Configured units will have parallel and
series links fitted as required.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Slimline Medically Approved power supply 750W
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
mite
Approved
Medically
Medical Power Supply patents pending
User Configurable 1U size
The XMD is the latest addition to the Excelsys range of the Xmite family of
medically approved power supplies. Providing up to an incredidble 750W(800W
PLUG & PLAY POWER peak) in a slimline 1U x 268 x 89mm package, the Xmite family is the smallest
next generation power source power supply in its class..
The XMD carries full safety agency approvals to EN60601-1 and UL2601-1, meeting
· EN60601-1 and UL2601-1 approved the stringent creepage requirements in this compact package. Providing up to 8
· Less than 300µA leakage current isolated outputs, the Xmite family is the most flexible power supply in its class and brings
· 4000VAC isolation affordable configurable power 750W medical market.
· Slimmest 750W configurable power The XMDpowerPac may be populated with up to 4 powerMods selected from the table
· Up to 800W peak power of powerMods shown below. Simply select your appropriate powerPac and powerMods
· Extra low profile: 1U height (40mm) to get your instant custom power solution.
· Ultra high efficiency, up to 89% This slimline product boasts unrivalled power density, providing significant system space
· Plug & Play Power savings. Combined with ultra-high efficiencies, the XMD provides system designers with
- allows fast custom configuration flexible instant solutions that significantly shorten system design-in time.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
- allow easy logistics For alternative power interfaces contact www.compumess.de Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
powerMods powerPacs
· FLEXIMOUNT Flexible mounting system
MODEL Vmin(4) Vnom Vmax(4) Imax Watts MODEL Watts
· Few electrolytic capacitors (all long life)
· Series / Parallel of multiple outputs Xg1 1.0 2.5 3.6 50A 125W XMD 750W
· 5V bias standby voltage provided Xg2 1.5 5.0 6.0 40A 200W
· Individual output control signals Xg3 4.0 12.0 15.0 20A 240W
Xg4 8.0 24.0 30.0 10A 240W
APPLICATIONS INCLUDE Xg5 8.0 48.0 58.0 6A 288W
· Radiological imaging
Xg7 5.0 24.0 28.0 5A 120W
· Clinical diagnostics
Xg8 V1 5.0 24.0 28.0 3A 72W
· Medical lasers
V2 5.0 24.0 28.0 3A 72W
· Clinical chemistry
· For non-medical applications see Xlite
EFFICIENCY (typical) MECHANICAL SPECIFICATIONS
93 1
92 Third angle projection
91
54.00 97.75
Efficiency %
90
122.00 92.00
89
J1
70C MAX OPERATING TEMPERATURE
SEE INSTRUCTION MANUAL
INPUT AC 100V-240V 50/60Hz
88 23.50
SLOT D
87
J2
SLOT C
86 42.00 TOP VIEW 19.00 89.00
SLOT B
85
23.50 SLOT A
84
70 85 100 115 130 145 160 175 190 205 220 235 260
Line Voltage VAC
40.40 29.50
All dimensions in mm.
Mounting Holes
4 M4 threaded holes on Base. Max screw penetration is 6mm from Base.
Series Fleximount Side Mounting Slots
Use with self-clinching studs type FH-M4-X or FH-832-X (X= stud length) from PEM, or equivalent
Alternatively, use Xgen Side Clamps from Excelsys. Part No. Z165 (drawing 61401)
750W Medical Plug & Play Power Supply Series
SPECIFICATION applies to configured units consisting of powerMods modules plugged into the appropriate powerPac
INPUT
Parameter Conditions/Description Min Nom Max Units
Input Voltage Range Universal Input 85 264 VAC
120 380 VDC
Approved
Input Frequency Range 47 63 Hz
Medically
Power Rating XMD Derate linearly from 750W at 140VAC to 525W at 85VAC. Note 5 750(800) W
Input Current XMD 85VAC in 525W out 7.5 A
Inrush Current 230VAC @ 25°C 50 A
Undervoltage Lockout Shutdown 65 74 VAC
Fusing XMD 250V 5 x 20mm F8A HRC
OUTPUT
Parameter Conditions/Description Min Nom Max Units
powerMod Power As per powerMod table
Output Adjustment Range Manual: Multi-turn potentiometer. As per powerMod table
Electronic: See Xgen Designers' Manual
Minimum Load 0 A
Line Regulation For ±10% change from nominal line ±0.1 %
Load Regulation For 25% to 75% load change ±0.2 %
Cross Regulation ±0.2 %
Transient Response For 25% to 75% load change Voltage Deviation 10 %
Settling Time 250 µs
Ripple and Noise 20MHz Bandwidth 1.0 % pk-pk
Overvoltage Protection Two-level. 1st level: Vset Tracking. 2nd level: Vmax (Latching) 110 125 %
Overcurrent Protection Straight line with hiccup activation at <30% of Vnom 110 120 %
See Designer's Manual for full details
Remote Sense Max. line drop compensation. (except Xg7, Xg8) 0.5 VDC
Overshoot 2 %
Turn-on Delay From AC In / Enable signal 1000 / 30 ms
Rise Time Monotonic 5 ms
Hold-up Time For nominal output voltages at full load 15 ms
Output Isolation Output to Output / Output to Chassis 500 / 500 VDC
GENERAL
Parameter Conditions/Description Min Nom Max Units
Isolation Voltage Input to Output 4000 VAC
Input to Chassis 1500 VAC
Efficiency 230VAC, 750W @ 24V 89 %
Safety Agency Approvals EN60601-1, UL2601-1, CSA601-1 UL File No. E230761
Leakage Current 250VAC, 60Hz, 25°C 300 µA
Signals See Xgen Series datasheet
Bias Supply Always ON. Current 250mA 4.8 5.0 5.2 VDC
Reliability Failures per million hours at 25°C and full load powerMod 0.98 fpmh
See Designers' Manual. powerPac excludes fans powerPac 0.92 fpmh
EMC
Parameter Standard Level Units
Emissions
Conducted EN55011, EN55022, FCC Level B
Radiated EN55011, EN55022, FCC Level B
Harmonic Distortion EN61000-3-2 Compliant
Flicker and Fluctuation EN61000-3-3 Compliant
Immunity
Electrostatic Discharge EN61000-4-2 Level 4
Radiated RFI EN61000-4-3 Level 3
Fast Transients - burst EN61000-4-4 Level 4
Input Line Surges EN61000-4-5 Class 4
Conducted RFI EN61000-4-6 10 V/m
Voltage Dips EN61000-4-11 (EN55024) 10 ms
ENVIRONMENTAL
Parameter Conditions/Description Min Nom Max Units
2 Operating Temperature -20 +70 °C
Storage Temperature -40 +85 °C
Derating 0.667% per °C from 40 to 50°C. 1.33% per °C from 60 to 70°C
Relative Humidity Non-condensing 5 95 %RH
Shock 3000 Bumps, 10G (16ms) half sine
Vibration 1.5G 10 200 Hz
NOTES 1. This product is not intended for use as a stand alone unit and must be installed by qualified personnel.
2. The specifications contained herein are believed to be correct at time of publication and are subject to change without notice.
3. All specifications at nominal input, full load, 25°C unless otherwise stated.
4. Vmin and Vmax voltages achieved when using Vtrim function on powerMod. Voltage setpints can also be adjusted adjusted using on board
potentiometer
5. 800W peak for 1s; Duty cycle 7%. powerMod output power must not exceed normal ratings
6. When powering inductive or capacitive loads, it is recommended to use a blocking diode on the output.
Doc. XMD Rev 02 11/09
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Xgen FLEXIBILITY and SIGNALS
Voltage Adjustment - Local Temperature Alarm (Option 01)
The multi-turn potentiometer that adjusts each output within the speci- Open collector signal indicating excessive powerPac temperatures due
fied range may be accessed via the output panel of the power supply. to fan failure or operation beyond ratings. This signal is activated at
Clockwise rotation increases output voltage. Resolution is approximate- least 10ms prior to system shutdown.
ly 5% of nominal voltage (Vnom) per turn.
Fan Fail (Option 01)
Voltage Adjustment - Remote (resistive / electronic) Open collector signal indicating that at least one of the system fans
The output voltage may be adjusted or trimmed by means of an exter- have failed. This does not cause system shutdown.
nal resistor or potentiometer network connected to the Vtrim pin. Linear
Electronic programming is also possible and may be implemented
according to the formula Vout = K Vcontrol. See Xgen series
Designers' Manual for full details.
Paralleling
To achieve increased current capacity, simply parallel outputs using the
standard parallel links. Excelsys `wireless' sharing ensures that current
hogging is not possible. To parallel connect outputs:
1. Switch on IShare switch to ON on powerMods.
2. Connect Negative parallel link.
3. Adjust output voltages of powerMods to within 5mV of eachother. Power Good
4. Connect Positive Parallel Link. Opto-isolated output signal indicates that the powerMod is operating
Parallel Links available to correctly and output voltage is within normal band.
order. Part Number XP1 Opto transistor ON = Good.
Seriesing
To achieve increased output voltages, simply series outputs using stan-
dard series links, paying attention to the requirements to maintain Indication LEDs
SELV levels if required in your system. Each powerMod has a visual indicator to identify that it is operating
Series Links available. Part within normal ratings. Very useful for system diagnosis.
Number XS1
Signal Connector Pinout
Pin J2 (powerPac) J3 (powerMod) J3 (powerMod)
Type A Type B)
Remote Sensing 1 common +sense +pg (V2)
2 +5V bias -sense -pg (V2)
When the load is remote from the power supply, the remote sense
pins may be used to compensate for drops in the power leads. 3 V trim inhibit (V2)
Where the power cabling contributes significant dynamic impedance, 4 ac fail I trim common (V2)
see Xgen series Designers' Manual. 5 fan fail* +inhibit/enable +pg (V1)
6 global enable -inhibit/enable -pg (V1)
Bias Voltage 7 temp alarm* +power good inhibit (V1)
A SELV isolated 5V (always on) bias voltage rated at 250mA is pro- 8 global inhibit -power good common (V1)
vided on J2 to facilitate miscellaneous control functions.
*Option 01 only
Current Limit Adjustment Signal Connector Pinout
The output current limit setting may be adjusted (downwards only) TYPE A Xg1-Xg7 TYPE B : Xg8
by means of an external resistor connection to the I trim pin.
Inhibit/Enable J3 J3
Inhibiting may be implemented either globally or on a per module Voltage V1 Adjust
3 Adjust
basis (powerPac or powerMod inhibiting). Reverse logic (Enabling)
V2 Adjust
may also be implemented, see Xgen series Designers' Manual. 2 1 2 1
J4
J4
AC Fail 4
Open collector signal indicating that the input voltage has failed or is 2
3
less than 80Vac. This signal changes state giving 5mS of warning
before loss of output regulation. See Xgen series Designers' Manual
2
for full specifications.
1
1
M4 Screws
J4 Connector : M4 Screw J4Connector : Camden 9200/4A
J3 Connector Mating Connector J3 Connector Mating Connector
Housing: Locking Molex 51110-0860 Housing: Locking Molex 51110-0860
Non Locking Molex 51110-0850 Non Locking Molex 51110-0850
Crimp Termnal: Molex p/n 50394 Crimp Termnal: Molex p/n 50394
See Xgen series Designers' Manual for full signal connector details.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Xgen Plug & Play Power Supply Series 200W to 1340W
Series
powerPacs (4slot package, 89mm wide)
Family MODEL Watts Family MODEL Watts
Xlite XLA 200W Xmite XMA 200W
Standard
XLB 400W XMB 400W
Med
XLC 600W XMC 600W
XLD 750W XMD 750W
Xkite XKA 200W Xrite XRA 200W
Noise
Noise
Low
Med
Low
XKB 400W XRB 400W
XKC 600W XRC 600W
powerPacs (6slot package, 127mm wide)
Family MODEL Watts Family MODEL Watts
Xcite XCA 400W Xvite XVA 400W
Standard
XCB 700W XVB 700W
Med
XCC 1000W XVC 1000W
XCD 1200W XVD 1200W
XCE 1340W XVE 1340W
Temp
Xhite XHA 400W Xzite XZA 400W
High
Noise
Med
Low
XHB 600W XZB 900W
Xqite XQA 400W XZC 1200W
Noise
Low
XQB 900W
XQC 1200W
powerMods (for use with all powerPac models)
MODEL Vmin(4) Vnom Vmax(4) Imax Watts
Vtrim Vpot
Xg1 1.0 1.5 2.5 3.6 50A 125W
Xg2 1.5 3.2 5.0 6.0 40A 200W
c
Xg3 4.0 6.0 12.0 15.0 20A 240W erPa
Xg4 8.0 12.0 24.0 30.0 10A 240W
pow
Xg5 8.0 24.0 48.0 58.0 6A 288W
powerMod
Xg7 5.0 5.0 24.0 28.0 5A 120W s
Xg8 V1 5.0 5.0 24.0 28.0 3A 72W
V2 5.0 5.0 24.0 28.0 3A 72W
Part Numbering XVC 1 2 3 4 0 0 - 00 Factory Use
Configured Units may be specified and ordered using the part
numbering system shown opposite. For example, part number Sum of option
4 codes
XVC123400-00 specifies the following 1000W medical power supply.
Model `-' = standard;
· XVC-00 powerPac 1000W medically approved powerPac
`P' = preset
· Xg1 2.5V @ 50A powerMod Slot A
· Xg2 5V @ 40A powerMod
Slot B Slot F
· Xg3 12V @ 20A powerMod
· Xg4 24V @ 10A powerMod Slot C Slot E
Slot D
Accessories .
PowerMods can be parallel connected for higher current and series
connected for higher voltages. Configured units will have parallel and
series links fitted as required.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Medically Approved Plug & Play Power Supply 400W-1200W
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
vite
Medical
Medically Approved patents pending
Ultra-high efficiency 1U size
The Xvite family of medically approved power supplies provides up to an
incredible 1200W in an extremely compact 1U x 260 x 127mm package. Providing
PLUG & PLAY POWER up to 12 isolated DC outputs, the Xvite family employs innovative plug & play
architecture allowing users to instantly configure a custom power solution in
next generation power source less than 5 minutes!
FEATURES The Xvite family consists of 4 powerPacs ranging in power levels from 400W to 1200W
and 7 powerMod DC output modules. Simply select the appropriate powerPac and up to
· UL2601-1 and EN60601-1 approved 6 powerMods from the tables below to complete your custom power supply.
· Less than 300µA leakage current
· 4000VAC isolation The Xvite family boasts an industry leading power density of 15W/in3 and ultra-high
· 1340W available (See XVE datasheet) efficiencies (up to 90%). The significant system space savings and reduced heat
dissipation radically simplify system design.
· Extra low profile: 1U height (40mm)
· Ultra high efficiency up to 90% All configurations carry full safety agency approvals including UL2601-1and EN60601-1
· Plug & Play Power and are CE marked. For alternative power interfaces contact support@excelsys.com
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
- allows fast custom configuration
- allow easy logistics
powerMods powerPacs
· Reduced system heat dissipation
MODEL Vmin Vnom Vmax Imax Watts MODEL Watts
· Few electrolytic capacitors (all long life)
· Visual LED indicators Xg1 1.5 2.5 3.6 50A 125W XVA 400W
Xvite
· Series / Parallel of multiple outputs Xg2 3.2 5.0 6.0 40A 200W XVB 700W
· 5V bias standby voltage provided Xg3 6.0 12.0 15.0 20A 240W XVC 1000W
· Individual output control signals Xg4 12.0 24.0 30.0 10A 240W XVD 1200W
Xg5 28.0 48.0 58.0 6A 288W
APPLICATIONS INCLUDE XVE 1340W
Xg7 5.0 24.0 28.0 5A 120W
· Clinical diagnostic equipment See XVE datasheet
Xg8 V1 5.0 24.0 28.0 3A 72W
· Medical lasers
V2 5.0 24.0 28.0 3A 72W
· Dialysis equipment
EFFICIENCY (typical) MECHANICAL SPECIFICATIONS
93 1
92 Third angle projection
91 50.00 97.75
Efficiency %
90
46.00 122.00 92.00
89
88 23.50
SLOT F
87 SLOT E
19.00
J1
70C MAX OPERATING TEMPERATURE
SEE INSTRUCTION MANUAL
INPUT AC 100V-240V 50/60Hz
86
TOP VIEW SLOT D
85 80.00 19.00 127.00
J2
SLOT C
84 19.00
70 85 100 115 130 145 160 175 190 205 220 235 260 SLOT B
Line Voltage VAC 23.50 SLOT A
40.40 29.50
All dimensions in mm.
Mounting Holes
4 M4 threaded holes on Base. Max screw penetration is 6mm from Base.
Series Fleximount Side Mounting Slots
Use with self-clinching studs type FH-M4-X or FH-832-X (X= stud length) from PEM, or equivalent
Alternatively, use Xgen Side Clamps from Excelsys. Part No. Z165 (drawing 61401)
400W-1200W AC/DC Plug & Play Power Supply Series
SPECIFICATION applies to configured units consisting of powerMods modules plugged into the appropriate powerPac
INPUT
Parameter Conditions/Decription Min Nom Max Units
Input Voltage Range Universal Input 85 264 VAC
120 380 VDC
Input Frequency Range 47 63 Hz
Medical
Power Rating XVA 400 W
XVB 700 W
XVC Derate linearly from 1000W at 100VAC to 850W at 85VAC 1000 W
XVD Derate linearly from 1200W at 120VAC to 850W at 85VAC 1200 W
Input Current XVA 85VAC in 400W out 7.5 A
XVB 85VAC in 700W out 9.5 A
XVC, XVD 85VAC in 850W out 11.5 A
Inrush Current 230VAC @ 25°C 25 A
Undervoltage Lockout Shutdown 65 74 VAC
Fusing XVA 250V F8A HRC
XVB 250V F10A HRC
XVC, XVD 250V F12A HRC
OUTPUT
Parameter Conditions/Description Min Nom Max Units
powerMod Power As per powerMod table
Output Adjustment Range Manual: Multi-turn potentiometer. As per powerMod table
Electronic: See Xgen Designers' Manual
Minimum Load 0 A
Line Regulation For ±10% change from nominal line ±0.1 %
Load & Cross Regulation For 25% to 75% load change ±0.2 %
Transient Response For 25% to 75% load change Voltage Deviation 10 %
Settling Time 250 µs
Ripple and Noise 20MHz Bandwidth 1.0 % pk-pk
Overvoltage Protection Two-level. 1st level: Vset Tracking. 2nd level: Vmax (Latching) 110 125 %
Overcurrent Protection Straight line with hiccup activation at <30% of Vnom 110 120 %
See Designer's Manual for full details
Remote Sense Max. line drop compensation. (except Xg7, Xg8) 0.5 VDC
Overshoot 2 %
Turn-on Delay From AC In / Enable signal 600 / 30 ms
Rise Time Monotonic 5 ms
Hold-up Time For nominal output voltages at full load. XCA,XCB,XCC / XCD 20 / 15 ms
Output Isolation Output to Output / Output to Chassis 500 / 500 VDC
GENERAL
Parameter Conditions/Description Min Nom Max Units
Isolation Voltage Input to Output 4000 VAC
Input to Chassis 1500 VAC
Efficiency 230VAC, 1200W @ 24V 90 %
Safety Agency Approvals EN60601-1, UL2601-1, CSA601-1 UL File No. E230761
Earth Leakage Current 250VAC, 60Hz, 25°C 300 µA
Signals See Xgen Series datasheet
Bias Supply Always ON. Current 250mA 4.8 5.0 5.5 VDC
Reliability Failures per million hours at 25°C and full load powerMod 0.98 fpmh
See Designers' Manual. powerPac excludes fans powerPac 0.92 fpmh
EMC
Parameter Standard Level Units
Emissions
Conducted EN55011, EN55022, FCC Level B
Radiated EN55011, EN55022, FCC Level B
Harmonic Distortion EN61000-3-2 Compliant
Flicker and Fluctuation EN61000-3-3 Compliant
Immunity
Electrostatic Discharge EN61000-4-2 Level 4
Radiated RFI EN61000-4-3 Level 3
Fast Transients - burst EN61000-4-4 Level 4
2 Input Line Surges EN61000-4-5 Class 4
Conducted RFI EN61000-4-6 10 V/m
Voltage Dips EN61000-4-11 (EN55024) 10 ms
ENVIRONMENTAL
Parameter Conditions/Description Min Nom Max Units
Operating Temperature -20 +70 °C
Storage Temperature -40 +85 °C
Derating 1.6% per °C above 40°C. See Designers Manual for full deratings
Relative Humidity Non-condensing 5 95 %RH
Shock 3000 Bumps, 10G (16ms) half sine
Vibration 1.5G 10 200 Hz
NOTES 1. This product is not intended for use as a stand alone unit and must be installed by qualified personnel.
2. The specifications contained herein are believed to be correct at time of publication and are subject to change without notice.
3. All specifications at nominal input, full load, 25°C unless otherwise stated.
4. When powering inductive or capacitive loads, it is recommended to use a blocking diode on the output. Doc. 40039 rev. 08 11/09
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Xgen FLEXIBILITY and SIGNALS
Voltage Adjustment - Local Temperature Alarm (Option 01)
The multi-turn potentiometer that adjusts each output within the speci- Open collector signal indicating excessive powerPac temperatures due
fied range may be accessed via the output panel of the power supply. to fan failure or operation beyond ratings. This signal is activated at
Clockwise rotation increases output voltage. Resolution is approximate- least 10ms prior to system shutdown.
ly 5% of nominal voltage (Vnom) per turn.
Fan Fail (Option 01)
Voltage Adjustment - Remote (resistive / electronic) Open collector signal indicating that at least one of the system fans
The output voltage may be adjusted or trimmed by means of an exter- have failed. This does not cause system shutdown.
nal resistor or potentiometer network connected to the Vtrim pin. Linear
Electronic programming is also possible and may be implemented
according to the formula Vout = K Vcontrol. See Xgen series
Designers' Manual for full details.
Paralleling
To achieve increased current capacity, simply parallel outputs using the
standard parallel links. Excelsys `wireless' sharing ensures that current
hogging is not possible. To parallel connect outputs:
1. Switch on IShare switch to ON on powerMods.
2. Connect Negative parallel link.
3. Adjust output voltages of powerMods to within 5mV of eachother. Power Good
4. Connect Positive Parallel Link. Opto-isolated output signal indicates that the powerMod is operating
Parallel Links available to correctly and output voltage is within normal band.
order. Part Number XP1 Opto transistor ON = Good.
Seriesing
To achieve increased output voltages, simply series outputs using stan-
dard series links, paying attention to the requirements to maintain Indication LEDs
SELV levels if required in your system. Each powerMod has a visual indicator to identify that it is operating
Series Links available. Part within normal ratings. Very useful for system diagnosis.
Number XS1
Signal Connector Pinout
Pin J2 (powerPac) J3 (powerMod) J3 (powerMod)
Type A Type B)
Remote Sensing 1 common +sense +pg (V2)
2 +5V bias -sense -pg (V2)
When the load is remote from the power supply, the remote sense
pins may be used to compensate for drops in the power leads. 3 V trim inhibit (V2)
Where the power cabling contributes significant dynamic impedance, 4 ac fail I trim common (V2)
see Xgen series Designers' Manual. 5 fan fail* +inhibit/enable +pg (V1)
6 global enable -inhibit/enable -pg (V1)
Bias Voltage 7 temp alarm* +power good inhibit (V1)
A SELV isolated 5V (always on) bias voltage rated at 250mA is pro- 8 global inhibit -power good common (V1)
vided on J2 to facilitate miscellaneous control functions.
*Option 01 only
Current Limit Adjustment Signal Connector Pinout
The output current limit setting may be adjusted (downwards only) TYPE A Xg1-Xg7 TYPE B : Xg8
by means of an external resistor connection to the I trim pin.
Inhibit/Enable J3 J3
Inhibiting may be implemented either globally or on a per module Voltage V1 Adjust
3 Adjust
basis (powerPac or powerMod inhibiting). Reverse logic (Enabling)
V2 Adjust
may also be implemented, see Xgen series Designers' Manual. 2 1 2 1
J4
J4
AC Fail 4
Open collector signal indicating that the input voltage has failed or is 2
3
less than 80Vac. This signal changes state giving 5mS of warning
before loss of output regulation. See Xgen series Designers' Manual
2
for full specifications.
1
1
M4 Screws
J4 Connector : M4 Screw J4Connector : Camden 9200/4A
J3 Connector Mating Connector J3 Connector Mating Connector
Housing: Locking Molex 51110-0860 Housing: Locking Molex 51110-0860
Non Locking Molex 51110-0850 Non Locking Molex 51110-0850
Crimp Termnal: Molex p/n 50394 Crimp Termnal: Molex p/n 50394
See Xgen series Designers' Manual for full signal connector details.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Xgen Plug & Play Power Supply Series 200W to 1340W
Series
powerPacs (4slot package, 89mm wide)
Family MODEL Watts Family MODEL Watts
Xlite XLA 200W Xmite XMA 200W
Standard
XLB 400W XMB 400W
Med
XLC 600W XMC 600W
XLD 750W XMD 750W
Xkite XKA 200W Xrite XRA 200W
Noise
Noise
Low
Med
Low
XKB 400W XRB 400W
XKC 600W XRC 600W
powerPacs (6slot package, 127mm wide)
Family MODEL Watts Family MODEL Watts
Xcite XCA 400W Xvite XVA 400W
Standard
XCB 700W XVB 700W
Med
XCC 1000W XVC 1000W
XCD 1200W XVD 1200W
XCE 1340W XVE 1340W
Temp
Xhite XHA 400W Xzite XZA 400W
High
Noise
Med
Low
XHB 600W XZB 900W
Xqite XQA 400W XZC 1200W
Noise
Low
XQB 900W
XQC 1200W
powerMods (for use with all powerPac models)
MODEL Vmin(4) Vnom Vmax(4) Imax Watts
Vtrim Vpot
Xg1 1.0 1.5 2.5 3.6 50A 125W
Xg2 1.5 3.2 5.0 6.0 40A 200W
c
Xg3 4.0 6.0 12.0 15.0 20A 240W erPa
Xg4 8.0 12.0 24.0 30.0 10A 240W
pow
Xg5 8.0 24.0 48.0 58.0 6A 288W
powerMod
Xg7 5.0 5.0 24.0 28.0 5A 120W s
Xg8 V1 5.0 5.0 24.0 28.0 3A 72W
V2 5.0 5.0 24.0 28.0 3A 72W
Part Numbering XVC 1 2 3 4 0 0 - 00 Factory Use
Configured Units may be specified and ordered using the part
numbering system shown opposite. For example, part number Sum of option
4 codes
XVC123400-00 specifies the following 1000W medical power supply.
Model `-' = standard;
· XVC-00 powerPac 1000W medically approved powerPac
`P' = preset
· Xg1 2.5V @ 50A powerMod Slot A
· Xg2 5V @ 40A powerMod
Slot B Slot F
· Xg3 12V @ 20A powerMod
· Xg4 24V @ 10A powerMod Slot C Slot E
Slot D
Accessories .
PowerMods can be parallel connected for higher current and series
connected for higher voltages. Configured units will have parallel and
series links fitted as required.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Medically Approved Plug & Play Power Supply 1340W
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
vite
Medical
Medically Approved patents pending
Ultra-high efficiency 1U size
The XVE addition to the Xgen family of medically approved power supplies
provides up to 1340W (peak power 1450W) in the most compact package of 1U x
PLUG & PLAY POWER 268mm x 127mm. Boasting an industry leading 17W/in3 and 90% efficiency, the
XVE can provide up to 12 isolated DC outputs. The XVE employs innovative plug
next generation power source & play architecture allowing users to instantly configure a custom power solution
in less than 5 minutes!
FEATURES
Ultra high efficiencies and high power density are made possible through the
· UL60601-1 and EN60601-1 approved combination of low loss technologies and best field-proven techniques in planar
· Less than 300µA leakage current magnetics and surface mount electronics. The significant system space savings and
· 4000VAC isolation reduced heat dissipation radically simplify system design.
· 1450W peak power for 10sec
The XVE can be populated with up to 6 powerMods selected from the table of
· Extra low profile: 1U height (40mm)
powerMods shown below.
· Ultra high efficiency up to 90%
· Plug & Play Power All configurations carry full safety agency approvals including UL60601-1and EN60601-1
- allows fast custom configuration and are CE marked. For alternative power interfaces contact support@excelsys.com CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
- allow easy logistics
powerMods powerPacs
· Reduced system heat dissipation
MODEL Vmin Vnom Vmax Imax Watts MODEL Watts
· Few electrolytic capacitors (all long life)
· Visual LED indicators Xg1 1.5 2.5 3.6 50A 125W XVE 1340W
· Series / Parallel of multiple outputs Xg2 3.2 5.0 6.0 40A 200W
· 5V bias standby voltage provided Xg3 6.0 12.0 15.0 20A 240W
· Individual output control signals Xg4 12.0 24.0 30.0 10A 240W
Xg5 28.0 48.0 58.0 6A 288W
APPLICATIONS INCLUDE
Xg7 5.0 24.0 28.0 5A 120W
· Clinical diagnostic equipment
· Medical lasers Xg8 V1 5.0 24.0 28.0 3A 72W
V2 5.0 24.0 28.0 3A 72W
· Dialysis equipment
· For Standard applications see XCE
EFFICIENCY (typical) MECHANICAL SPECIFICATIONS
93 1
92 Third angle projection
91 54.00 97.75
Efficiency %
90 122.00 92.00
89
23.50 SLOT F
88
87 SLOT E
19.00
J1
70C MAX OPERATING TEMPERATURE
SEE INSTRUCTION MANUAL
INPUT AC 100V-240V 50/60Hz
86 TOP VIEW SLOT D
80.00 19.00 127.00
85 SLOT C
J2
19.00
84
SLOT B
70 85 100 115 130 145 160 175 190 205 220 235 260
SLOT A
Line Voltage VAC 23.50
40.40 29.50
All dimensions in mm.
Mounting Holes
4 M4 threaded holes on Base. Max screw penetration is 6mm from Base.
Series Fleximount Side Mounting Slots
Use with self-clinching studs type FH-M4-X or FH-832-X (X= stud length) from PEM, or equivalent
Alternatively, use Xgen Side Clamps from Excelsys. Part No. Z165 (drawing 61401)
1340W Medically Approved Plug & Play Power Supply Series
SPECIFICATION applies to configured units consisting of powerMods modules plugged into the appropriate powerPac
INPUT
Parameter Conditions/Decription Min Nom Max Units
Input Voltage Range Universal Input 85 264 VAC
120 380 VDC
Input Frequency Range 47 63 Hz
Medical
Power Rating XVE See Xgen Designers' Manual for derating versus input line voltage 1340(1450) W
Input Current XVE 85VAC in 1000W out 14.0 A
Inrush Current 230VAC @ 25°C 25 A
Undervoltage Lockout Shutdown 65 74 VAC
Fusing XVE 250V F15A HRC
OUTPUT
Parameter Conditions/Description Min Nom Max Units
powerMod Power As per powerMod table
Output Adjustment Range Manual: Multi-turn potentiometer. As per powerMod table
Electronic: See Xgen Designers' Manual
Minimum Load 0 A
Line Regulation For ±10% change from nominal line ±0.1 %
Load & Cross Regulation For 25% to 75% load change ±0.2 %
Transient Response For 25% to 75% load change Voltage Deviation 10 %
Settling Time 250 µs
Ripple and Noise 20MHz Bandwidth 1.0 % pk-pk
Overvoltage Protection Two-level. 1st level: Vset Tracking. 2nd level: Vmax (Latching) 110 125 %
Overcurrent Protection Straight line with hiccup activation at <30% of Vnom 110 120 %
See Designer's Manual for full details
Remote Sense Max. line drop compensation. (except Xg7, Xg8) 0.5 VDC
Overshoot 2 %
Turn-on Delay From AC In / Enable signal 700 / 30 ms
Rise Time Monotonic 5 ms
Hold-up Time For nominal output voltages at full load. 230VAC/115VAC 15 ms
Output Isolation Output to Output / Output to Chassis 500 / 500 VDC
GENERAL
Parameter Conditions/Description Min Nom Max Units
Isolation Voltage Input to Output 4000 VAC
Input to Chassis 1500 VAC
Efficiency 230VAC, 1340W @ 24V 90 %
Safety Agency Approvals EN60601-1, UL2601-1, CSA601-1 UL File No. E230761
Earth Leakage Current 250VAC, 60Hz, 25°C 300 µA
Signals See Xgen Series datasheet
Bias Supply Always ON. Current 30mA 4.8 5.0 5.2 VDC
Reliability Failures per million hours at 25°C and full load powerMod 0.98 fpmh
See Designers' Manual. powerPac excludes fans powerPac 0.92 fpmh
EMC
Parameter Standard Level Units
Emissions
Conducted EN55011, EN55022, FCC Level B
Radiated EN55011, EN55022, FCC Level B
Harmonic Distortion EN61000-3-2 Compliant
Flicker and Fluctuation EN61000-3-3 Compliant
Immunity
Electrostatic Discharge EN61000-4-2 Level 4
Radiated RFI EN61000-4-3 Level 3
Fast Transients - burst EN61000-4-4 Level 4
Input Line Surges EN61000-4-5 Class 4
Conducted RFI EN61000-4-6 10 V/m
Voltage Dips EN61000-4-11 (EN55024) 10 ms
ENVIRONMENTAL
Parameter Conditions/Description Min Nom Max Units
Operating Temperature -20 +70 °C
2 Storage Temperature -40 +85 °C
Derating See Designers Manual for full deratings versus temperature
Relative Humidity Non-condensing 5 95 %RH
Shock 3000 Bumps, 10G (16ms) half sine
Vibration 1.5G 10 200 Hz
NOTES 1. This product is not intended for use as a stand alone unit and must be installed by qualified personnel.
2. The specifications contained herein are believed to be correct at time of publication and are subject to change without notice.
3. All specifications at nominal input, full load, 25°C unless otherwise stated.
4. 1450W peak for 10s; Duty cycle 8%. powerMod output power must not exceed normal ratings
5. When powering inductive or capacitive loads, it is recommended to use a blocking diode on the output.
XVE Rev 02 11/09
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Xgen FLEXIBILITY and SIGNALS
Voltage Adjustment - Local Temperature Alarm (Option 01)
The multi-turn potentiometer that adjusts each output within the speci- Open collector signal indicating excessive powerPac temperatures due
fied range may be accessed via the output panel of the power supply. to fan failure or operation beyond ratings. This signal is activated at
Clockwise rotation increases output voltage. Resolution is approximate- least 10ms prior to system shutdown.
ly 5% of nominal voltage (Vnom) per turn.
Fan Fail (Option 01)
Voltage Adjustment - Remote (resistive / electronic) Open collector signal indicating that at least one of the system fans
The output voltage may be adjusted or trimmed by means of an exter- have failed. This does not cause system shutdown.
nal resistor or potentiometer network connected to the Vtrim pin. Linear
Electronic programming is also possible and may be implemented
according to the formula Vout = K Vcontrol. See Xgen series
Designers' Manual for full details.
Paralleling
To achieve increased current capacity, simply parallel outputs using the
standard parallel links. Excelsys `wireless' sharing ensures that current
hogging is not possible. To parallel connect outputs:
1. Switch on IShare switch to ON on powerMods.
2. Connect Negative parallel link.
3. Adjust output voltages of powerMods to within 5mV of eachother. Power Good
4. Connect Positive Parallel Link. Opto-isolated output signal indicates that the powerMod is operating
Parallel Links available to correctly and output voltage is within normal band.
order. Part Number XP1 Opto transistor ON = Good.
Seriesing
To achieve increased output voltages, simply series outputs using stan-
dard series links, paying attention to the requirements to maintain Indication LEDs
SELV levels if required in your system. Each powerMod has a visual indicator to identify that it is operating
Series Links available. Part within normal ratings. Very useful for system diagnosis.
Number XS1
Signal Connector Pinout
Pin J2 (powerPac) J3 (powerMod) J3 (powerMod)
Type A Type B)
Remote Sensing 1 common +sense +pg (V2)
2 +5V bias -sense -pg (V2)
When the load is remote from the power supply, the remote sense
pins may be used to compensate for drops in the power leads. 3 V trim inhibit (V2)
Where the power cabling contributes significant dynamic impedance, 4 ac fail I trim common (V2)
see Xgen series Designers' Manual. 5 fan fail* +inhibit/enable +pg (V1)
6 global enable -inhibit/enable -pg (V1)
Bias Voltage 7 temp alarm* +power good inhibit (V1)
A SELV isolated 5V (always on) bias voltage rated at 250mA is pro- 8 global inhibit -power good common (V1)
vided on J2 to facilitate miscellaneous control functions.
*Option 01 only
Current Limit Adjustment Signal Connector Pinout
The output current limit setting may be adjusted (downwards only) TYPE A Xg1-Xg7 TYPE B : Xg8
by means of an external resistor connection to the I trim pin.
Inhibit/Enable J3 J3
Inhibiting may be implemented either globally or on a per module Voltage V1 Adjust
3 Adjust
basis (powerPac or powerMod inhibiting). Reverse logic (Enabling)
V2 Adjust
may also be implemented, see Xgen series Designers' Manual. 2 1 2 1
J4
J4
AC Fail 4
Open collector signal indicating that the input voltage has failed or is 2
3
less than 80Vac. This signal changes state giving 5mS of warning
before loss of output regulation. See Xgen series Designers' Manual
2
for full specifications.
1
1
M4 Screws
J4 Connector : M4 Screw J4Connector : Camden 9200/4A
J3 Connector Mating Connector J3 Connector Mating Connector
Housing: Locking Molex 51110-0860 Housing: Locking Molex 51110-0860
Non Locking Molex 51110-0850 Non Locking Molex 51110-0850
Crimp Termnal: Molex p/n 50394 Crimp Termnal: Molex p/n 50394
See Xgen series Designers' Manual for full signal connector details.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Xgen Plug & Play Power Supply Series 200W to 1340W
Series
powerPacs (4slot package, 89mm wide)
Family MODEL Watts Family MODEL Watts
Xlite XLA 200W Xmite XMA 200W
Standard
XLB 400W XMB 400W
Med
XLC 600W XMC 600W
XLD 750W XMD 750W
Xkite XKA 200W Xrite XRA 200W
Noise
Noise
Low
Med
Low
XKB 400W XRB 400W
XKC 600W XRC 600W
powerPacs (6slot package, 127mm wide)
Family MODEL Watts Family MODEL Watts
Xcite XCA 400W Xvite XVA 400W
Standard
XCB 700W XVB 700W
Med
XCC 1000W XVC 1000W
XCD 1200W XVD 1200W
XCE 1340W XVE 1340W
Temp
Xhite XHA 400W Xzite XZA 400W
High
Noise
Med
Low
XHB 600W XZB 900W
Xqite XQA 400W XZC 1200W
Noise
Low
XQB 900W
XQC 1200W
powerMods (for use with all powerPac models)
MODEL Vmin(4) Vnom Vmax(4) Imax Watts
Vtrim Vpot
Xg1 1.0 1.5 2.5 3.6 50A 125W
Xg2 1.5 3.2 5.0 6.0 40A 200W
c
Xg3 4.0 6.0 12.0 15.0 20A 240W erPa
Xg4 8.0 12.0 24.0 30.0 10A 240W
pow
Xg5 8.0 24.0 48.0 58.0 6A 288W
powerMod
Xg7 5.0 5.0 24.0 28.0 5A 120W s
Xg8 V1 5.0 5.0 24.0 28.0 3A 72W
V2 5.0 5.0 24.0 28.0 3A 72W
Part Numbering XVC 1 2 3 4 0 0 - 00 Factory Use
Configured Units may be specified and ordered using the part
numbering system shown opposite. For example, part number Sum of option
4 codes
XVC123400-00 specifies the following 1000W medical power supply.
Model `-' = standard;
· XVC-00 powerPac 1000W medically approved powerPac
`P' = preset
· Xg1 2.5V @ 50A powerMod Slot A
· Xg2 5V @ 40A powerMod
Slot B Slot F
· Xg3 12V @ 20A powerMod
· Xg4 24V @ 10A powerMod Slot C Slot E
Slot D
Accessories .
PowerMods can be parallel connected for higher current and series
connected for higher voltages. Configured units will have parallel and
series links fitted as required.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Hi-Temp AC/DC Plug & Play Power Supply Series 400W-600W
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
hite
Hi-Temp
Hi-Temp Power Supply patents pending
Ultra-high efficiency 1U size
The Xhite family of high temperature power supplies provides up to 600W in an
extremely compact 1U x 260 x 127mm package. Designed as a configurable
PLUG & PLAY POWER power supply, the Xhite family employs the innovative plug and play architecture
that allows users to instantly configure a custom power solution in less than 5
next generation power source minutes.
FEATURES The Xhite family is ideal for use in harsh environments where there can be high ambient
temperatures and wide temperature fluctuations. Operation at higher temperatures is
· -20° to +70°C operating ambient temp
C made possible through employment of leading edge technologies and cooling
· 1.5V to 58V standard output voltages techniques, making it possible for the Xhite to achieve unprecedented efficiencies of up to
· All outputs fully floating 90%.
· Extra low profile: 1U height (40mm)
The Xhite family consists of 2 powerPac models ranging in power levels from 400W to
· Ultra high efficiency, up to 90%
600W. Each model may be populated with up to 6 powerMods selected from the table
· Plug & Play Power of powerMods shown below.
- allows fast custom configuration
- allow easy maintenance logistics All configurations carry full safety agency approvals, UL60950, EN60950 and are CE
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
· Reduced system heat dissipation marked. For alternative power interfaces contact support@excelsys.com Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
· Few electrolytic capacitors (all long life) powerMods powerPacs
· Visual LED indicators MODEL Vmin Vnom Vmax Imax Watts MODEL Watts
· Series / Parallel of multiple outputs
Xg1 1.5 2.5 3.6 25A 65W
· 5V bias standby voltage provided
Xhite
Xg2 3.2 5.0 6.0 20A 100W XHA 400W
· Individual output control signals
Xg3 6.0 12.0 15.0 10A 120W
APPLICATIONS INCLUDE Xg4 12.0 24.0 30.0 5A 120W XHB 600W
· Industrial equipment Xg5 28.0 48.0 58.0 3A 144W
· Telecommunications Xg7 5.0 24.0 28.0 2.5A 60W
· Outdoor display systems Xg8 V1 5.0 24.0 28.0 1.5A 36W
V2 5.0 24.0 28.0 1.5A 36W
EFFICIENCY (typical) MECHANICAL SPECIFICATIONS
93 1
92 Third angle projection
91 50.00 97.75
Efficiency %
90
46.00 122.00 92.00
89
88 23.50
SLOT F
87 SLOT E
19.00
J1
70C MAX OPERATING TEMPERATURE
SEE INSTRUCTION MANUAL
INPUT AC 100V-240V 50/60Hz
86
TOP VIEW SLOT D
85 80.00 19.00 127.00
J2
SLOT C
84 19.00
70 85 100 115 130 145 160 175 190 205 220 235 260 SLOT B
Line Voltage VAC 23.50 SLOT A
40.40 29.50
All dimensions in mm.
Mounting Holes
4 M4 threaded holes on Base. Max screw penetration is 6mm from Base.
Series Fleximount Side Mounting Slots
Use with self-clinching studs type FH-M4-X or FH-832-X (X= stud length) from PEM, or equivalent
Alternatively, use Xgen Side Clamps from Excelsys. Part No. Z165 (drawing 61401)
400W-600W Hi-Temp AC/DC Plug & Play Power Supply Series
SPECIFICATION applies to configured units consisting of powerMods modules plugged into the appropriate powerPac
INPUT
Parameter Conditions/Description Min Nom Max Units
Input Voltage Range Universal Input 85 264 VAC
120 380 VDC
Input Frequency Range 47 63 Hz
Hi-Temp
Power Rating XHA 400 W
XHB Derate linearly from 600W at 120Vac to 425W at 85Vac 600 W
Input Current XHA 85VAC in 400W out 6.5 A
XHB 85VAC in 425W out 7.5 A
Inrush Current 230VAC @ 25°C 25 A
Undervoltage Lockout Shutdown 65 74 VAC
Fusing XHA 250V F10A HRC
XHB 250V F12A HRC
OUTPUT
Parameter Conditions/Description Min Nom Max Units
powerMod Power As per powerMod table
Output Adjustment Range Manual: Multi-turn potentiometer. As per powerMod table
Electronic: See Xgen Designers' Manual
Minimum Load 0 A
Line Regulation For ±10% change from nominal line ±0.1 %
Load & Cross Regulation For 25% to 75% load change ±0.2 %
Transient Response For 25% to 75% load change Voltage Deviation 10 %
Settling Time 250 µs
Ripple and Noise 20MHz Bandwidth 1.0 % pk-pk
Overvoltage Protection 1st level: Vset Tracking. 2nd level: Vmax (Latching) 110 125 %
Overcurrent Protection Straight line with hiccup activation at <30% of Vnom 110 120 %
See Designer's Manual for full details
Remote Sense Max. line drop compensation. (except Xg7, Xg8) 0.5 VDC
Overshoot 2 %
Turn-on Delay From AC In / Enable signal 600 / 30 ms
Rise Time Monotonic 5 ms
Hold-up Time For nominal output voltages at full load. 20 ms
Output Isolation Output to Output / Output to Chassis 500 / 500 VDC
GENERAL
Parameter Conditions/Description Min Nom Max Units
Isolation Voltage Input to Output 3000 VAC
Input to Chassis 1500 VAC
Efficiency 230VAC, 900W @ 24V 90 %
Safety Agency Approvals EN60950, UL60950, CSA22.2 No.950 UL File No. E181875
Leakage Current 250VAC, 60Hz, 25°C 1.5 mA
Signals See Xgen Series datasheet
Bias Supply Always ON. Current 250mA 4.8 5.0 5.2 VDC
Reliability Failures per million hours at 25°C and full load powerMod 0.98 fpmh
See Designers' Manual. powerPac excludes fans powerPac 0.92 fpmh
EMC
Parameter Standard Level Units
Emissions
Conducted EN55011, EN55022, FCC Level B
Radiated EN55011, EN55022, FCC Level B
Harmonic Distortion EN61000-3-2 Compliant
Flicker and Fluctuation EN61000-3-3 Compliant
Immunity
Electrostatic Discharge EN61000-4-2 Level 4
Radiated RFI EN61000-4-3 Level 3
Fast Transients - burst EN61000-4-4 Level 4
Input Line Surges EN61000-4-5 Class 4
Conducted RFI EN61000-4-6 10 V/m
Voltage Dips EN61000-4-11 (EN55024) 10 ms
2
ENVIRONMENTAL
Parameter Conditions/Description Min Nom Max Units
Operating Temperature Full Load -20 +70 °C
Storage Temperature -40 +85 °C
Derating None
Relative Humidity Non-condensing 5 95 %RH
Shock 3000 Bumps, 10G (16ms) half sine
Vibration 1.5G 10 200 Hz
NOTES 1. This product is not intended for use as a stand alone unit and must be installed by qualified personnel.
2. The specifications contained herein are believed to be correct at time of publication and are subject to change without notice.
3. All specifications at nominal input, full load, 25°C unless otherwise stated.
4. When powering inductive or capacitive loads, it is recommended to use a blocking diode on the output.
Doc. 40041 rev. 08 11/09
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Xgen FLEXIBILITY and SIGNALS
Voltage Adjustment - Local Temperature Alarm (Option 01)
The multi-turn potentiometer that adjusts each output within the speci- Open collector signal indicating excessive powerPac temperatures due
fied range may be accessed via the output panel of the power supply. to fan failure or operation beyond ratings. This signal is activated at
Clockwise rotation increases output voltage. Resolution is approximate- least 10ms prior to system shutdown.
ly 5% of nominal voltage (Vnom) per turn.
Fan Fail (Option 01)
Voltage Adjustment - Remote (resistive / electronic) Open collector signal indicating that at least one of the system fans
The output voltage may be adjusted or trimmed by means of an exter- have failed. This does not cause system shutdown.
nal resistor or potentiometer network connected to the Vtrim pin. Linear
Electronic programming is also possible and may be implemented
according to the formula Vout = K Vcontrol. See Xgen series
Designers' Manual for full details.
Paralleling
To achieve increased current capacity, simply parallel outputs using the
standard parallel links. Excelsys `wireless' sharing ensures that current
hogging is not possible. To parallel connect outputs:
1. Switch on IShare switch to ON on powerMods.
2. Connect Negative parallel link.
3. Adjust output voltages of powerMods to within 5mV of eachother. Power Good
4. Connect Positive Parallel Link. Opto-isolated output signal indicates that the powerMod is operating
Parallel Links available to correctly and output voltage is within normal band.
order. Part Number XP1 Opto transistor ON = Good.
Seriesing
To achieve increased output voltages, simply series outputs using stan-
dard series links, paying attention to the requirements to maintain Indication LEDs
SELV levels if required in your system. Each powerMod has a visual indicator to identify that it is operating
Series Links available. Part within normal ratings. Very useful for system diagnosis.
Number XS1
Signal Connector Pinout
Pin J2 (powerPac) J3 (powerMod) J3 (powerMod)
Type A Type B)
Remote Sensing 1 common +sense +pg (V2)
2 +5V bias -sense -pg (V2)
When the load is remote from the power supply, the remote sense
pins may be used to compensate for drops in the power leads. 3 V trim inhibit (V2)
Where the power cabling contributes significant dynamic impedance, 4 ac fail I trim common (V2)
see Xgen series Designers' Manual. 5 fan fail* +inhibit/enable +pg (V1)
6 global enable -inhibit/enable -pg (V1)
Bias Voltage 7 temp alarm* +power good inhibit (V1)
A SELV isolated 5V (always on) bias voltage rated at 250mA is pro- 8 global inhibit -power good common (V1)
vided on J2 to facilitate miscellaneous control functions.
*Option 01 only
Current Limit Adjustment Signal Connector Pinout
The output current limit setting may be adjusted (downwards only) TYPE A Xg1-Xg7 TYPE B : Xg8
by means of an external resistor connection to the I trim pin.
Inhibit/Enable J3 J3
Inhibiting may be implemented either globally or on a per module Voltage V1 Adjust
3 Adjust
basis (powerPac or powerMod inhibiting). Reverse logic (Enabling)
V2 Adjust
may also be implemented, see Xgen series Designers' Manual. 2 1 2 1
J4
J4
AC Fail 4
Open collector signal indicating that the input voltage has failed or is 2
3
less than 80Vac. This signal changes state giving 5mS of warning
before loss of output regulation. See Xgen series Designers' Manual
2
for full specifications.
1
1
M4 Screws
J4 Connector : M4 Screw J4Connector : Camden 9200/4A
J3 Connector Mating Connector J3 Connector Mating Connector
Housing: Locking Molex 51110-0860 Housing: Locking Molex 51110-0860
Non Locking Molex 51110-0850 Non Locking Molex 51110-0850
Crimp Termnal: Molex p/n 50394 Crimp Termnal: Molex p/n 50394
See Xgen series Designers' Manual for full signal connector details.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Xgen Plug & Play Power Supply Series 200W to 1340W
Series
powerPacs (4slot package, 89mm wide)
Family MODEL Watts Family MODEL Watts
Xlite XLA 200W Xmite XMA 200W
Standard
XLB 400W XMB 400W
Med
XLC 600W XMC 600W
XLD 750W XMD 750W
Xkite XKA 200W Xrite XRA 200W
Noise
Noise
Low
Med
Low
XKB 400W XRB 400W
XKC 600W XRC 600W
powerPacs (6slot package, 127mm wide)
Family MODEL Watts Family MODEL Watts
Xcite XCA 400W Xvite XVA 400W
Standard
XCB 700W XVB 700W
Med
XCC 1000W XVC 1000W
XCD 1200W XVD 1200W
XCE 1340W XVE 1340W
Temp
Xhite XHA 400W Xzite XZA 400W
High
Noise
Med
Low
XHB 600W XZB 900W
Xqite XQA 400W XZC 1200W
Noise
Low
XQB 900W
XQC 1200W
powerMods (for use with all powerPac models)
MODEL Vmin(4) Vnom Vmax(4) Imax Watts
Vtrim Vpot
Xg1 1.0 1.5 2.5 3.6 50A 125W
Xg2 1.5 3.2 5.0 6.0 40A 200W
c
Xg3 4.0 6.0 12.0 15.0 20A 240W erPa
Xg4 8.0 12.0 24.0 30.0 10A 240W
pow
Xg5 8.0 24.0 48.0 58.0 6A 288W
powerMod
Xg7 5.0 5.0 24.0 28.0 5A 120W s
Xg8 V1 5.0 5.0 24.0 28.0 3A 72W
V2 5.0 5.0 24.0 28.0 3A 72W
Part Numbering XVC 1 2 3 4 0 0 - 00 Factory Use
Configured Units may be specified and ordered using the part
numbering system shown opposite. For example, part number Sum of option
4 codes
XVC123400-00 specifies the following 1000W medical power supply.
Model `-' = standard;
· XVC-00 powerPac 1000W medically approved powerPac
`P' = preset
· Xg1 2.5V @ 50A powerMod Slot A
· Xg2 5V @ 40A powerMod
Slot B Slot F
· Xg3 12V @ 20A powerMod
· Xg4 24V @ 10A powerMod Slot C Slot E
Slot D
Accessories .
PowerMods can be parallel connected for higher current and series
connected for higher voltages. Configured units will have parallel and
series links fitted as required.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Low Noise AC/DC Plug & Play Power Supply Series 200W-600W
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
kite
Low Noise
Slimline Power Supply patents pending
User Configurable 1U size
The Xkite family of low noise power supplies provides up to 600W in a slimline 1U
x 260 x 89mm package. Providing up to 8 isolated outputs, the Xkite family is the
PLUG & PLAY POWER most flexible power supply in its class and brings affordable configurable power
next generation power source to the 200-600W market.
Ideal for acoustic sensitive applications, the Xkite boasts unrivalled power density saving
FEATURES valuable system space. Combine with ultra high efficiencies, the Xkite family provides
· Low Acoustic Noise 54dBA system designers with flexible instant solutions that significantly shorten and simplify
· Slimmest 600W configurable power system design-in time.
· Extra low profile: 1U height (40mm)
The Xkite family consists of 3 powerPac models in 200W, 400W and 600W power levels.
· All outputs fully floating
Each powerPac model may be populated with up to 4 powerMods selected from the
· Ultra high efficiency, up to 89% table of powerMods shown below.
· Plug & Play Power
- allows fast custom configuration All configurations carry full safety agency approvals, UL60950, EN60950 and are CE
marked. For alternative power interfaces contact support@excelsys.com
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
- allow easy logistics Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
· FLEXIMOUNT Flexible mounting system
powerMods powerPacs
· Few electrolytic capacitors (all long life)
MODEL Vmin Vnom Vmax Imax Watts MODEL Watts
· Visual LED indicators
· Series / Parallel of multiple outputs Xg1 1.5 2.5 3.6 50A 125W XKA 200W
Xkite
· 5V bias standby voltage provided Xg2 3.2 5.0 6.0 40A 200W XKB 400W
· Individual output control signals Xg3 6.0 12.0 15.0 20A 240W XKC 600W
Xg4 12.0 24.0 30.0 10A 240W
APPLICATIONS INCLUDE Xg5 28.0 48.0 58.0 6A 288W
· Audio Equipment
Xg7 5.0 24.0 28.0 5A 120W
· Test and measurement
Xg8 V1 5.0 24.0 28.0 3A 72W
· Telecommunications
V2 5.0 24.0 28.0 3A 72W
· For Medical applications see Xrite
EFFICIENCY (typical) MECHANICAL SPECIFICATIONS
93 1
92 Third angle projection
91 50.00 97.75
Efficiency %
90
46.00 122.00 92.00
89
J1
70C MAX OPERATING TEMPERATURE
SEE INSTRUCTION MANUAL
INPUT AC 100V-240V 50/60Hz
88 23.50
SLOT D
87
J2
SLOT C
42.00 19.00 89.00
86 TOP VIEW
SLOT B
85
23.50 SLOT A
84
70 85 100 115 130 145 160 175 190 205 220 235 260
Line Voltage VAC
40.40 29.50
All dimensions in mm.
Mounting Holes
4 M4 threaded holes on Base. Max screw penetration is 6mm from Base.
Series Fleximount Side Mounting Slots
Use with self-clinching studs type FH-M4-X or FH-832-X (X= stud length) from PEM, or equivalent
Alternatively, use Xgen Side Clamps from Excelsys. Part No. Z165 (drawing 61401)
200W-600W Slimline Low Noise Plug & Play Power Supply Series
SPECIFICATION applies to configured units consisting of powerMods modules plugged into the appropriate powerPac
INPUT
Parameter Conditions/Description Min Nom Max Units
Input Voltage Range Universal Input 85 264 VAC
120 380 VDC
Input Frequency Range 47 63 Hz
Low Noise
Power Rating XKA 200 W
XKB 400 W
XKC 600 W
Input Current XKA 85VAC in 200W out 4.5 A
XKB 85VAC in 400W out 5.5 A
XKC 85VAC in 600W out 7.5 A
Inrush Current 230VAC @ 25°C 50 A
Undervoltage Lockout Shutdown 65 74 VAC
Fusing XKA 250V 5 x 20mm F5A HRC
XKB 250V 5 x 20mm F6.3A HRC
XKC 250V 5 x 20mm F8A HRC
OUTPUT
Parameter Conditions/Description Min Nom Max Units
powerMod Power As per powerMod table
Output Adjustment Range Manual: Multi-turn potentiometer. As per powerMod table
Electronic: See Xgen Designers' Manual
Minimum Load 0 A
Line Regulation For ±10% change from nominal line ±0.1 %
Load Regulation For 25% to 75% load change ±0.2 %
Cross Regulation ±0.2 %
Transient Response For 25% to 75% load change Voltage Deviation 10 %
Settling Time 250 µs
Ripple and Noise 20MHz Bandwidth 1.0 % pk-pk
Overvoltage Protection Two-level. 1st level: Vset Tracking. 2nd level: Vmax (Latching) 110 125 %
Overcurrent Protection Straight line with hiccup activation at <30% of Vnom 110 120 %
See Designer's Manual for full details
Remote Sense Max. line drop compensation. (except Xg7, Xg8) 0.5 VDC
Overshoot 2 %
Turn-on Delay From AC In / Enable signal 600 / 30 ms
Rise Time Monotonic 5 ms
Hold-up Time For nominal output voltages at full load 20 ms
Output Isolation Output to Output / Output to Chassis 500 / 500 VDC
GENERAL
Parameter Conditions/Description Min Nom Max Units
Isolation Voltage Input to Output 3000 VAC
Input to Chassis 1500 VAC
Efficiency 230VAC, 600W @ 24V 89 %
Safety Agency Approvals EN60950, UL60950, CSA22.2 No.950 UL File No. E181875
Leakage Current 250VAC, 60Hz, 25°C 1.5 mA
Signals See Xgen Series datasheet
Bias Supply Always ON. Current 250mA 4.8 5.0 5.2 VDC
Reliability Failures per million hours at 25°C and full load powerMod 0.98 fpmh
See Designers' Manual. powerPac excludes fans powerPac 0.92 fpmh
EMC
Parameter Standard Level Units
Emissions
Conducted EN55011, EN55022, FCC Level B
Radiated EN55011, EN55022, FCC Level B
Harmonic Distortion EN61000-3-2 Compliant
Flicker and Fluctuation EN61000-3-3 Compliant
Immunity
Electrostatic Discharge EN61000-4-2 Level 4
Radiated RFI EN61000-4-3 Level 3
Fast Transients - burst EN61000-4-4 Level 4
Input Line Surges EN61000-4-5 Class 4
2 Conducted RFI EN61000-4-6 10 V/m
Voltage Dips EN61000-4-11 (EN55024) 10 ms
ENVIRONMENTAL
Parameter Conditions/Description Min Nom Max Units
Operating Temperature -20 +70 °C
Storage Temperature -40 +85 °C
Derating See Designers Manual for full deratings
Relative Humidity Non-condensing 5 95 %RH
Acoustic Noise Background noise 28.6dBA, Noise measured 1m from unit 54 dBA
Shock 3000 Bumps, 10G (16ms) half sine
Vibration 1.5G 10 200 Hz
NOTES 1. This product is not intended for use as a stand alone unit and must be installed by qualified personnel.
2. The specifications contained herein are believed to be correct at time of publication and are subject to change without notice.
3. All specifications at nominal input, full load, 25°C unless otherwise stated.
4. When powering inductive or capacitive loads, it is recommended to use a blocking diode on the output. Xkite Rev 08 11/09
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Xgen FLEXIBILITY and SIGNALS
Voltage Adjustment - Local Temperature Alarm (Option 01)
The multi-turn potentiometer that adjusts each output within the speci- Open collector signal indicating excessive powerPac temperatures due
fied range may be accessed via the output panel of the power supply. to fan failure or operation beyond ratings. This signal is activated at
Clockwise rotation increases output voltage. Resolution is approximate- least 10ms prior to system shutdown.
ly 5% of nominal voltage (Vnom) per turn.
Fan Fail (Option 01)
Voltage Adjustment - Remote (resistive / electronic) Open collector signal indicating that at least one of the system fans
The output voltage may be adjusted or trimmed by means of an exter- have failed. This does not cause system shutdown.
nal resistor or potentiometer network connected to the Vtrim pin. Linear
Electronic programming is also possible and may be implemented
according to the formula Vout = K Vcontrol. See Xgen series
Designers' Manual for full details.
Paralleling
To achieve increased current capacity, simply parallel outputs using the
standard parallel links. Excelsys `wireless' sharing ensures that current
hogging is not possible. To parallel connect outputs:
1. Switch on IShare switch to ON on powerMods.
2. Connect Negative parallel link.
3. Adjust output voltages of powerMods to within 5mV of eachother. Power Good
4. Connect Positive Parallel Link. Opto-isolated output signal indicates that the powerMod is operating
Parallel Links available to correctly and output voltage is within normal band.
order. Part Number XP1 Opto transistor ON = Good.
Seriesing
To achieve increased output voltages, simply series outputs using stan-
dard series links, paying attention to the requirements to maintain Indication LEDs
SELV levels if required in your system. Each powerMod has a visual indicator to identify that it is operating
Series Links available. Part within normal ratings. Very useful for system diagnosis.
Number XS1
Signal Connector Pinout
Pin J2 (powerPac) J3 (powerMod) J3 (powerMod)
Type A Type B)
Remote Sensing 1 common +sense +pg (V2)
2 +5V bias -sense -pg (V2)
When the load is remote from the power supply, the remote sense
pins may be used to compensate for drops in the power leads. 3 V trim inhibit (V2)
Where the power cabling contributes significant dynamic impedance, 4 ac fail I trim common (V2)
see Xgen series Designers' Manual. 5 fan fail* +inhibit/enable +pg (V1)
6 global enable -inhibit/enable -pg (V1)
Bias Voltage 7 temp alarm* +power good inhibit (V1)
A SELV isolated 5V (always on) bias voltage rated at 250mA is pro- 8 global inhibit -power good common (V1)
vided on J2 to facilitate miscellaneous control functions.
*Option 01 only
Current Limit Adjustment Signal Connector Pinout
The output current limit setting may be adjusted (downwards only) TYPE A Xg1-Xg7 TYPE B : Xg8
by means of an external resistor connection to the I trim pin.
Inhibit/Enable J3 J3
Inhibiting may be implemented either globally or on a per module Voltage V1 Adjust
3 Adjust
basis (powerPac or powerMod inhibiting). Reverse logic (Enabling)
V2 Adjust
may also be implemented, see Xgen series Designers' Manual. 2 1 2 1
J4
J4
AC Fail 4
Open collector signal indicating that the input voltage has failed or is 2
3
less than 80Vac. This signal changes state giving 5mS of warning
before loss of output regulation. See Xgen series Designers' Manual
2
for full specifications.
1
1
M4 Screws
J4 Connector : M4 Screw J4Connector : Camden 9200/4A
J3 Connector Mating Connector J3 Connector Mating Connector
Housing: Locking Molex 51110-0860 Housing: Locking Molex 51110-0860
Non Locking Molex 51110-0850 Non Locking Molex 51110-0850
Crimp Termnal: Molex p/n 50394 Crimp Termnal: Molex p/n 50394
See Xgen series Designers' Manual for full signal connector details.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Xgen Plug & Play Power Supply Series 200W to 1340W
Series
powerPacs (4slot package, 89mm wide)
Family MODEL Watts Family MODEL Watts
Xlite XLA 200W Xmite XMA 200W
Standard
XLB 400W XMB 400W
Med
XLC 600W XMC 600W
XLD 750W XMD 750W
Xkite XKA 200W Xrite XRA 200W
Noise
Noise
Low
Med
Low
XKB 400W XRB 400W
XKC 600W XRC 600W
powerPacs (6slot package, 127mm wide)
Family MODEL Watts Family MODEL Watts
Xcite XCA 400W Xvite XVA 400W
Standard
XCB 700W XVB 700W
Med
XCC 1000W XVC 1000W
XCD 1200W XVD 1200W
XCE 1340W XVE 1340W
Temp
Xhite XHA 400W Xzite XZA 400W
High
Noise
Med
Low
XHB 600W XZB 900W
Xqite XQA 400W XZC 1200W
Noise
Low
XQB 900W
XQC 1200W
powerMods (for use with all powerPac models)
MODEL Vmin(4) Vnom Vmax(4) Imax Watts
Vtrim Vpot
Xg1 1.0 1.5 2.5 3.6 50A 125W
Xg2 1.5 3.2 5.0 6.0 40A 200W
c
Xg3 4.0 6.0 12.0 15.0 20A 240W erPa
Xg4 8.0 12.0 24.0 30.0 10A 240W
pow
Xg5 8.0 24.0 48.0 58.0 6A 288W
powerMod
Xg7 5.0 5.0 24.0 28.0 5A 120W s
Xg8 V1 5.0 5.0 24.0 28.0 3A 72W
V2 5.0 5.0 24.0 28.0 3A 72W
Part Numbering XVC 1 2 3 4 0 0 - 00 Factory Use
Configured Units may be specified and ordered using the part
numbering system shown opposite. For example, part number Sum of option
4 codes
XVC123400-00 specifies the following 1000W medical power supply.
Model `-' = standard;
· XVC-00 powerPac 1000W medically approved powerPac
`P' = preset
· Xg1 2.5V @ 50A powerMod Slot A
· Xg2 5V @ 40A powerMod
Slot B Slot F
· Xg3 12V @ 20A powerMod
· Xg4 24V @ 10A powerMod Slot C Slot E
Slot D
Accessories .
PowerMods can be parallel connected for higher current and series
connected for higher voltages. Configured units will have parallel and
series links fitted as required.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Low Noise AC/DC Plug & Play Power Supply Series 400W-1200W
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
qite
Low Noise
Low Noise Power Supply patents pending
Ultra-high efficiency 1U size
The Xqite family of low noise power supplies provides up to 1200W in an
extremely compact 1U x 260 x 127mm package. Boasting industry leading power
PLUG & PLAY POWER density of 15W/in3 and efficiencies of up to 90%, the Xqite family employs an
innovative plug & play architecture that allows users to instantly configure a
next generation power source custom power solution in less than 5 minutes!
FEATURES Ideal for acoustic sensitive applications such as audio applications, the Xqite family
provides unmatched efficiency and high power density, made possible through the
· Low Acoustic Noise 59dBA combination of low loss technologies and the best field-proven technologies in planar
· 1.5V to 58V standard output voltages magnetics and surface mount electronics.
· All outputs fully floating
· Extra low profile: 1U height (40mm) The Xqite family consists of 2 powerPac models ranging in power levels from 400W to
1200W. Each model may be populated with up to 6 powerMods selected from the
· Ultra high efficiency, up to 90%
table of powerMods shown below.
· Plug & Play Power
- allows fast custom configuration All configurations carry full safety agency approvals, UL60950, EN60950 and are CE
- allow easy logistics marked. For alternative power interfaces contact support@excelsys.com CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
· Reduced system heat dissipation
powerMods powerPacs
· Few electrolytic capacitors (all long life)
MODEL Vmin Vnom Vmax Imax Watts MODEL Watts
· Visual LED indicators
· Series / Parallel of multiple outputs Xg1 1.5 2.5 3.6 50A 125W XQA 600W
Xqite
· 5V bias standby voltage provided Xg2 3.2 5.0 6.0 40A 200W XQB 900W
· Individual output control signals Xg3 6.0 12.0 15.0 20A 240W XQC 1200W
Xg4 12.0 24.0 30.0 10A 240W
APPLICATIONS INCLUDE Xg5 28.0 48.0 58.0 6A 288W
· Audio Equipment
Xg7 5.0 24.0 28.0 5A 120W
· Test and measurement
Xg8 V1 5.0 24.0 28.0 3A 72W
· Telecommunications
V2 5.0 24.0 28.0 3A 72W
· For Medical applications, See Xzite
EFFICIENCY (typical) MECHANICAL SPECIFICATIONS
93 1
92 Third angle projection
91 50.00 97.75
Efficiency %
90
46.00 122.00 92.00
89
88 23.50
SLOT F
87 SLOT E
19.00
J1
70C MAX OPERATING TEMPERATURE
SEE INSTRUCTION MANUAL
INPUT AC 100V-240V 50/60Hz
86
TOP VIEW SLOT D
85 80.00 19.00 127.00
J2
SLOT C
84 19.00
70 85 100 115 130 145 160 175 190 205 220 235 260 SLOT B
Line Voltage VAC 23.50 SLOT A
40.40 29.50
All dimensions in mm.
Mounting Holes
4 M4 threaded holes on Base. Max screw penetration is 6mm from Base.
Series Fleximount Side Mounting Slots
Use with self-clinching studs type FH-M4-X or FH-832-X (X= stud length) from PEM, or equivalent
Alternatively, use Xgen Side Clamps from Excelsys. Part No. Z165 (drawing 61401)
400W-1200W Low Noise AC/DC Plug & Play Power Supply Series
SPECIFICATION applies to configured units consisting of powerMods modules plugged into the appropriate powerPac
INPUT
Parameter Conditions/Description Min Nom Max Units
Input Voltage Range Universal Input 85 264 VAC
120 380 VDC
Input Frequency Range 47 63 Hz
Low Noise
Power Rating XQA 400 W
XQB 900
XQC Derate linearly from 1200W at 120VAC to 850W at 85VAC 1200 W
Input Current XQA 85VAC in 400W out 7.5 A
XQB 85VAC in 850W out 11.5 A
XQC 85VACin 1200W ouot 11.5 A
Inrush Current 230VAC @ 25°C 25 A
Undervoltage Lockout Shutdown 65 74 VAC
Fusing XQA 250V F8A HRC
XQB 250V F12A HRC
XQC 250V F12A HRC
OUTPUT
Parameter Conditions/Description Min Nom Max Units
powerMod Power As per powerMod table
Output Adjustment Range Manual: Multi-turn potentiometer. As per powerMod table
Electronic: See Xgen Designers' Manual
Minimum Load 0 A
Line Regulation For ±10% change from nominal line ±0.1 %
Load & Cross Regulation For 25% to 75% load change ±0.2 %
Transient Response For 25% to 75% load change Voltage Deviation 10 %
Settling Time 250 µs
Ripple and Noise 20MHz Bandwidth 1.0 % pk-pk
Overvoltage Protection 1st level: Vset Tracking. 2nd level: Vmax (Latching) 110 125 %
Overcurrent Protection Straight line with hiccup activation at <30% of Vnom 110 120 %
See Designer's Manual for full details
Remote Sense Max. line drop compensation. (except Xg7, Xg8) 0.5 VDC
Overshoot 2 %
Turn-on Delay From AC In / Enable signal 600 / 30 ms
Rise Time Monotonic 5 ms
Hold-up Time For nominal output voltages at full load. XQA / XQB & XQC 20 / 15 ms
Output Isolation Output to Output / Output to Chassis 500 / 500 VDC
GENERAL
Parameter Conditions/Description Min Nom Max Units
Isolation Voltage Input to Output 3000 VAC
Input to Chassis 1500 VAC
Efficiency 230VAC, 1200W @ 24V 90 %
Safety Agency Approvals EN60950, UL60950, CSA22.2 No.950 UL File No. E181875
Leakage Current 250VAC, 60Hz, 25°C 1.5 mA
Signals See Xgen Designer's Manual for full details
Bias Supply Always ON. Current 250mA 4.8 5.0 5.2 VDC
Reliability Failures per million hours at 25°C and full load powerMod 0.98 fpmh
See Designers' Manual. powerPac excludes fans powerPac 0.92 fpmh
EMC
Parameter Standard Level Units
Emissions
Conducted EN55011, EN55022, FCC Level B
Radiated EN55011, EN55022, FCC Level B
Harmonic Distortion EN61000-3-2 Compliant
Flicker and Fluctuation EN61000-3-3 Compliant
Immunity
Electrostatic Discharge EN61000-4-2 Level 4
Radiated RFI EN61000-4-3 Level 3
Fast Transients - burst EN61000-4-4 Level 4
Input Line Surges EN61000-4-5 Class 4
Conducted RFI EN61000-4-6 10 V/m
2 Voltage Dips EN61000-4-11 (EN55024) 10 ms
ENVIRONMENTAL
Parameter Conditions/Description Min Nom Max Units
Operating Temperature -20 +70 °C
Storage Temperature -40 +85 °C
Derating See Xgen Designers Manual deratings
Relative Humidity Non-condensing 5 95 %RH
Acoustic Noise Background noise 28.6dBA, Noise measured 1m from unit 59 dBA
Shock 3000 Bumps, 10G (16ms) half sine
Vibration 1.5G 10 200 Hz
NOTES 1. This product is not intended for use as a stand alone unit and must be installed by qualified personnel.
2. The specifications contained herein are believed to be correct at time of publication and are subject to change without notice.
3. All specifications at nominal input, full load, 25°C unless otherwise stated.
4. See Xgen Designers Manual for detailed power ratings
5. When powering inductive or capacitive loads, it is recommended to use a blocking diode on the output. Doc. 40042 rev. 08 11/09
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Xgen FLEXIBILITY and SIGNALS
Voltage Adjustment - Local Temperature Alarm (Option 01)
The multi-turn potentiometer that adjusts each output within the speci- Open collector signal indicating excessive powerPac temperatures due
fied range may be accessed via the output panel of the power supply. to fan failure or operation beyond ratings. This signal is activated at
Clockwise rotation increases output voltage. Resolution is approximate- least 10ms prior to system shutdown.
ly 5% of nominal voltage (Vnom) per turn.
Fan Fail (Option 01)
Voltage Adjustment - Remote (resistive / electronic) Open collector signal indicating that at least one of the system fans
The output voltage may be adjusted or trimmed by means of an exter- have failed. This does not cause system shutdown.
nal resistor or potentiometer network connected to the Vtrim pin. Linear
Electronic programming is also possible and may be implemented
according to the formula Vout = K Vcontrol. See Xgen series
Designers' Manual for full details.
Paralleling
To achieve increased current capacity, simply parallel outputs using the
standard parallel links. Excelsys `wireless' sharing ensures that current
hogging is not possible. To parallel connect outputs:
1. Switch on IShare switch to ON on powerMods.
2. Connect Negative parallel link.
3. Adjust output voltages of powerMods to within 5mV of eachother. Power Good
4. Connect Positive Parallel Link. Opto-isolated output signal indicates that the powerMod is operating
Parallel Links available to correctly and output voltage is within normal band.
order. Part Number XP1 Opto transistor ON = Good.
Seriesing
To achieve increased output voltages, simply series outputs using stan-
dard series links, paying attention to the requirements to maintain Indication LEDs
SELV levels if required in your system. Each powerMod has a visual indicator to identify that it is operating
Series Links available. Part within normal ratings. Very useful for system diagnosis.
Number XS1
Signal Connector Pinout
Pin J2 (powerPac) J3 (powerMod) J3 (powerMod)
Type A Type B)
Remote Sensing 1 common +sense +pg (V2)
2 +5V bias -sense -pg (V2)
When the load is remote from the power supply, the remote sense
pins may be used to compensate for drops in the power leads. 3 V trim inhibit (V2)
Where the power cabling contributes significant dynamic impedance, 4 ac fail I trim common (V2)
see Xgen series Designers' Manual. 5 fan fail* +inhibit/enable +pg (V1)
6 global enable -inhibit/enable -pg (V1)
Bias Voltage 7 temp alarm* +power good inhibit (V1)
A SELV isolated 5V (always on) bias voltage rated at 250mA is pro- 8 global inhibit -power good common (V1)
vided on J2 to facilitate miscellaneous control functions.
*Option 01 only
Current Limit Adjustment Signal Connector Pinout
The output current limit setting may be adjusted (downwards only) TYPE A Xg1-Xg7 TYPE B : Xg8
by means of an external resistor connection to the I trim pin.
Inhibit/Enable J3 J3
Inhibiting may be implemented either globally or on a per module Voltage V1 Adjust
3 Adjust
basis (powerPac or powerMod inhibiting). Reverse logic (Enabling)
V2 Adjust
may also be implemented, see Xgen series Designers' Manual. 2 1 2 1
J4
J4
AC Fail 4
Open collector signal indicating that the input voltage has failed or is 2
3
less than 80Vac. This signal changes state giving 5mS of warning
before loss of output regulation. See Xgen series Designers' Manual
2
for full specifications.
1
1
M4 Screws
J4 Connector : M4 Screw J4Connector : Camden 9200/4A
J3 Connector Mating Connector J3 Connector Mating Connector
Housing: Locking Molex 51110-0860 Housing: Locking Molex 51110-0860
Non Locking Molex 51110-0850 Non Locking Molex 51110-0850
Crimp Termnal: Molex p/n 50394 Crimp Termnal: Molex p/n 50394
See Xgen series Designers' Manual for full signal connector details.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Xgen Plug & Play Power Supply Series 200W to 1340W
Series
powerPacs (4slot package, 89mm wide)
Family MODEL Watts Family MODEL Watts
Xlite XLA 200W Xmite XMA 200W
Standard
XLB 400W XMB 400W
Med
XLC 600W XMC 600W
XLD 750W XMD 750W
Xkite XKA 200W Xrite XRA 200W
Noise
Noise
Low
Med
Low
XKB 400W XRB 400W
XKC 600W XRC 600W
powerPacs (6slot package, 127mm wide)
Family MODEL Watts Family MODEL Watts
Xcite XCA 400W Xvite XVA 400W
Standard
XCB 700W XVB 700W
Med
XCC 1000W XVC 1000W
XCD 1200W XVD 1200W
XCE 1340W XVE 1340W
Temp
Xhite XHA 400W Xzite XZA 400W
High
Noise
Med
Low
XHB 600W XZB 900W
Xqite XQA 400W XZC 1200W
Noise
Low
XQB 900W
XQC 1200W
powerMods (for use with all powerPac models)
MODEL Vmin(4) Vnom Vmax(4) Imax Watts
Vtrim Vpot
Xg1 1.0 1.5 2.5 3.6 50A 125W
Xg2 1.5 3.2 5.0 6.0 40A 200W
c
Xg3 4.0 6.0 12.0 15.0 20A 240W erPa
Xg4 8.0 12.0 24.0 30.0 10A 240W
pow
Xg5 8.0 24.0 48.0 58.0 6A 288W
powerMod
Xg7 5.0 5.0 24.0 28.0 5A 120W s
Xg8 V1 5.0 5.0 24.0 28.0 3A 72W
V2 5.0 5.0 24.0 28.0 3A 72W
Part Numbering XVC 1 2 3 4 0 0 - 00 Factory Use
Configured Units may be specified and ordered using the part
numbering system shown opposite. For example, part number Sum of option
4 codes
XVC123400-00 specifies the following 1000W medical power supply.
Model `-' = standard;
· XVC-00 powerPac 1000W medically approved powerPac
`P' = preset
· Xg1 2.5V @ 50A powerMod Slot A
· Xg2 5V @ 40A powerMod
Slot B Slot F
· Xg3 12V @ 20A powerMod
· Xg4 24V @ 10A powerMod Slot C Slot E
Slot D
Accessories .
PowerMods can be parallel connected for higher current and series
connected for higher voltages. Configured units will have parallel and
series links fitted as required.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Low Noise Medically Approved Power Supply 200W-600W
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
rite
Low Noise
Medical
Medical Power Supply patents pending
Low Noise 1U size
The Xrite family of low noise medically approved power supplies provides up to
600W in a slimline 1U x 260 x 89mm package. Ideal for acoustoc sensitive
PLUG & PLAY POWER medical equipment, the Xrite family carries full safety agency approvals to
next generation power source EN60601-1 and UL2601-1, meeting the stringent creepage requirements in this
compact package. Providing up to 8 isolated outputs, the Xrite family is the most
FEATURES flexible power supply in its class and brings affordable configurable power to the
200-600W medical market.
· Low Acoustic Noise 54dBA
· EN60601-1 and UL2601-1 approved The Xrite family consists of 3 powerPac models in 200W, 400W and 600W power levels.
Each powerPac model may be populated with up to 4 powerMods selected from the
· Less than 300µA leakage current
table of powerMods shown below. Simply select your appropriate powerPac and
· 4000VAC isolation powerMods to get your instant custom power solution.
· Slimmest 600W configurable power
· Extra low profile: 1U height (40mm) This slimline product boasts unrivalled power density, providing significant system space
· Ultra high efficiency, up to 89% savings. Combined with ultra-high efficiencies, the Xrite family provides system designers
with flexible instant solutions that significantly shorten system design-in time. For
· Plug & Play Power CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
alternative power interfaces contact support@excelsys.com Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
- allows fast custom configuration
powerMods powerPacs
- allow easy logistics
MODEL Vmin Vnom Vmax Imax Watts MODEL Watts
· FLEXIMOUNT Flexible mounting system
· Few electrolytic capacitors (all long life) Xg1 1.5 2.5 3.6 50A 125W XRA 200W
Xrite
· Series / Parallel of multiple outputs Xg2 3.2 5.0 6.0 40A 200W XRB 400W
· 5V bias standby voltage provided Xg3 6.0 12.0 15.0 20A 240W
XRC 600W
· Individual output control signals Xg4 12.0 24.0 30.0 10A 240W
Xg5 28.0 48.0 58.0 6A 288W
APPLICATIONS INCLUDE
Xg7 5.0 24.0 28.0 5A 120W
· Radiological imaging
Xg8 V1 5.0 24.0 28.0 3A 72W
· Clinical diagnostics
V2 5.0 24.0 28.0 3A 72W
· Medical lasers
· Clinical chemistry
· For non-medical applications see Xkite
EFFICIENCY (typical) MECHANICAL SPECIFICATIONS
93 1
92 Third angle projection
91 50.00 97.75
Efficiency %
90
46.00 122.00 92.00
89
J1
70C MAX OPERATING TEMPERATURE
SEE INSTRUCTION MANUAL
INPUT AC 100V-240V 50/60Hz
88 23.50
SLOT D
87
J2
SLOT C
86 42.00 TOP VIEW 19.00 89.00
SLOT B
85
23.50 SLOT A
84
70 85 100 115 130 145 160 175 190 205 220 235 260
Line Voltage VAC
40.40 29.50
All dimensions in mm.
Mounting Holes
4 M4 threaded holes on Base. Max screw penetration is 6mm from Base.
Series Fleximount Side Mounting Slots
Use with self-clinching studs type FH-M4-X or FH-832-X (X= stud length) from PEM, or equivalent
Alternatively, use Xgen Side Clamps from Excelsys. Part No. Z165 (drawing 61401)
200W-600W Low Noise Medically Approved Power Supply
SPECIFICATION applies to configured units consisting of powerMods modules plugged into the appropriate powerPac
INPUT
Parameter Conditions/Description Min Nom Max Units
Input Voltage Range Universal Input 85 264 VAC
120 380 VDC
Input Frequency Range 47 63 Hz
Power Rating XRA 200 W
Low Noise
Medical
XRB 400 W
XRC 600 W
Input Current XRA 85VAC in 200W out 4.5 A
XRB 85VAC in 400W out 5.5 A
XRC 85VAC in 600W out 7.5 A
Inrush Current 230VAC @ 25°C 50 A
Undervoltage Lockout Shutdown 65 74 VAC
Fusing XRA 250V 5 x 20mm F5A HRC
XRB 250V 5 x 20mm F6.3A HRC
XRC 250V 5 x 20mm F8A HRC
OUTPUT
Parameter Conditions/Description Min Nom Max Units
powerMod Power As per powerMod table
Output Adjustment Range Manual: Multi-turn potentiometer. As per powerMod table
Electronic: See Xgen Designers' Manual
Minimum Load 0 A
Line Regulation For ±10% change from nominal line ±0.1 %
Load Regulation For 25% to 75% load change ±0.2 %
Cross Regulation ±0.2 %
Transient Response For 25% to 75% load change Voltage Deviation 10 %
Settling Time 250 µs
Ripple and Noise 20MHz Bandwidth 1.0 % pk-pk
Overvoltage Protection 1st level: Vset Tracking. 2nd level: Vmax (Latching) 110 125 %
Overcurrent Protection Straight line with hiccup activation at <30% of Vnom 110 120 %
See Designer's Manual for full details
Remote Sense Max. line drop compensation. (except Xg7, Xg8) 0.5 VDC
Overshoot 2 %
Turn-on Delay From AC In / Enable signal 600 / 30 ms
Rise Time Monotonic 5 ms
Hold-up Time For nominal output voltages at full load 20 ms
Output Isolation Output to Output / Output to Chassis 500 / 500 VDC
GENERAL
Parameter Conditions/Description Min Nom Max Units
Isolation Voltage Input to Output 4000 VAC
Input to Chassis 1500 VAC
Efficiency 230VAC, 600W @ 24V 89 %
Safety Agency Approvals EN60601-1, UL2601-1, CSA601-1 UL File No. E230761
Leakage Current 250VAC, 60Hz, 25°C 300 µA
Signals See Xgen Series datasheet
Bias Supply Always ON. Current 250mA 4.8 5.0 5.2 VDC
Reliability Failures per million hours at 25°C and full load powerMod 0.98 fpmh
See Designers' Manual. powerPac excludes fans powerPac 0.92 fpmh
EMC
Parameter Standard Level Units
Emissions
Conducted EN55011, EN55022, FCC Level B
Radiated EN55011, EN55022, FCC Level B
Harmonic Distortion EN61000-3-2 Compliant
Flicker and Fluctuation EN61000-3-3 Compliant
Immunity
Electrostatic Discharge EN61000-4-2 Level 4
Radiated RFI EN61000-4-3 Level 3
Fast Transients - burst EN61000-4-4 Level 4
Input Line Surges EN61000-4-5 Class 4
2 Conducted RFI EN61000-4-6 10 V/m
Voltage Dips EN61000-4-11 (EN55024) 10 ms
ENVIRONMENTAL
Parameter Conditions/Description Min Nom Max Units
Operating Temperature -20 +70 °C
Storage Temperature -40 +85 °C
Derating See Designers Manual for full deratings
Relative Humidity Non-condensing 5 95 %RH
Acoustic Noise Background noise 28.6dBA, Noise measured 1m from unit 54 dBA
Shock 3000 Bumps, 10G (16ms) half sine
Vibration 1.5G 10 200 Hz
NOTES 1. This product is not intended for use as a stand alone unit and must be installed by qualified personnel.
2. The specifications contained herein are believed to be correct at time of publication and are subject to change without notice.
3. All specifications at nominal input, full load, 25°C unless otherwise stated.
4. When powering inductive or capacitive loads, it is recommended to use a blocking diode on the output. Xrite rev 08 11/09
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Xgen FLEXIBILITY and SIGNALS
Voltage Adjustment - Local Temperature Alarm (Option 01)
The multi-turn potentiometer that adjusts each output within the speci- Open collector signal indicating excessive powerPac temperatures due
fied range may be accessed via the output panel of the power supply. to fan failure or operation beyond ratings. This signal is activated at
Clockwise rotation increases output voltage. Resolution is approximate- least 10ms prior to system shutdown.
ly 5% of nominal voltage (Vnom) per turn.
Fan Fail (Option 01)
Voltage Adjustment - Remote (resistive / electronic) Open collector signal indicating that at least one of the system fans
The output voltage may be adjusted or trimmed by means of an exter- have failed. This does not cause system shutdown.
nal resistor or potentiometer network connected to the Vtrim pin. Linear
Electronic programming is also possible and may be implemented
according to the formula Vout = K Vcontrol. See Xgen series
Designers' Manual for full details.
Paralleling
To achieve increased current capacity, simply parallel outputs using the
standard parallel links. Excelsys `wireless' sharing ensures that current
hogging is not possible. To parallel connect outputs:
1. Switch on IShare switch to ON on powerMods.
2. Connect Negative parallel link.
3. Adjust output voltages of powerMods to within 5mV of eachother. Power Good
4. Connect Positive Parallel Link. Opto-isolated output signal indicates that the powerMod is operating
Parallel Links available to correctly and output voltage is within normal band.
order. Part Number XP1 Opto transistor ON = Good.
Seriesing
To achieve increased output voltages, simply series outputs using stan-
dard series links, paying attention to the requirements to maintain Indication LEDs
SELV levels if required in your system. Each powerMod has a visual indicator to identify that it is operating
Series Links available. Part within normal ratings. Very useful for system diagnosis.
Number XS1
Signal Connector Pinout
Pin J2 (powerPac) J3 (powerMod) J3 (powerMod)
Type A Type B)
Remote Sensing 1 common +sense +pg (V2)
2 +5V bias -sense -pg (V2)
When the load is remote from the power supply, the remote sense
pins may be used to compensate for drops in the power leads. 3 V trim inhibit (V2)
Where the power cabling contributes significant dynamic impedance, 4 ac fail I trim common (V2)
see Xgen series Designers' Manual. 5 fan fail* +inhibit/enable +pg (V1)
6 global enable -inhibit/enable -pg (V1)
Bias Voltage 7 temp alarm* +power good inhibit (V1)
A SELV isolated 5V (always on) bias voltage rated at 250mA is pro- 8 global inhibit -power good common (V1)
vided on J2 to facilitate miscellaneous control functions.
*Option 01 only
Current Limit Adjustment Signal Connector Pinout
The output current limit setting may be adjusted (downwards only) TYPE A Xg1-Xg7 TYPE B : Xg8
by means of an external resistor connection to the I trim pin.
Inhibit/Enable J3 J3
Inhibiting may be implemented either globally or on a per module Voltage V1 Adjust
3 Adjust
basis (powerPac or powerMod inhibiting). Reverse logic (Enabling)
V2 Adjust
may also be implemented, see Xgen series Designers' Manual. 2 1 2 1
J4
J4
AC Fail 4
Open collector signal indicating that the input voltage has failed or is 2
3
less than 80Vac. This signal changes state giving 5mS of warning
before loss of output regulation. See Xgen series Designers' Manual for
2
full specifications.
1
1
M4 Screws
J4 Connector : M4 Screw J4Connector : Camden 9200/4A
J3 Connector Mating Connector J3 Connector Mating Connector
Housing: Locking Molex 51110-0860 Housing: Locking Molex 51110-0860
Non Locking Molex 51110-0850 Non Locking Molex 51110-0850
Crimp Termnal: Molex p/n 50394 Crimp Termnal: Molex p/n 50394
See Xgen series Designers' Manual for full signal connector details.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Xgen Plug & Play Power Supply Series 200W to 1340W
Series
powerPacs (4slot package, 89mm wide)
Family MODEL Watts Family MODEL Watts
Xlite XLA 200W Xmite XMA 200W
Standard
XLB 400W XMB 400W
Med
XLC 600W XMC 600W
XLD 750W XMD 750W
Xkite XKA 200W Xrite XRA 200W
Noise
Noise
Low
Med
Low
XKB 400W XRB 400W
XKC 600W XRC 600W
powerPacs (6slot package, 127mm wide)
Family MODEL Watts Family MODEL Watts
Xcite XCA 400W Xvite XVA 400W
Standard
XCB 700W XVB 700W
Med
XCC 1000W XVC 1000W
XCD 1200W XVD 1200W
XCE 1340W XVE 1340W
Temp
Xhite XHA 400W Xzite XZA 400W
High
Noise
Med
Low
XHB 600W XZB 900W
Xqite XQA 400W XZC 1200W
Noise
Low
XQB 900W
XQC 1200W
powerMods (for use with all powerPac models)
MODEL Vmin(4) Vnom Vmax(4) Imax Watts
Vtrim Vpot
Xg1 1.0 1.5 2.5 3.6 50A 125W
Xg2 1.5 3.2 5.0 6.0 40A 200W
c
Xg3 4.0 6.0 12.0 15.0 20A 240W erPa
Xg4 8.0 12.0 24.0 30.0 10A 240W
pow
Xg5 8.0 24.0 48.0 58.0 6A 288W
powerMod
Xg7 5.0 5.0 24.0 28.0 5A 120W s
Xg8 V1 5.0 5.0 24.0 28.0 3A 72W
V2 5.0 5.0 24.0 28.0 3A 72W
Part Numbering XVC 1 2 3 4 0 0 - 00 Factory Use
Configured Units may be specified and ordered using the part
numbering system shown opposite. For example, part number Sum of option
4 codes
XVC123400-00 specifies the following 1000W medical power supply.
Model `-' = standard;
· XVC-00 powerPac 1000W medically approved powerPac
`P' = preset
· Xg1 2.5V @ 50A powerMod Slot A
· Xg2 5V @ 40A powerMod
Slot B Slot F
· Xg3 12V @ 20A powerMod
· Xg4 24V @ 10A powerMod Slot C Slot E
Slot D
Accessories .
PowerMods can be parallel connected for higher current and series
connected for higher voltages. Configured units will have parallel and
series links fitted as required.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Medical Low Noise AC/DC Plug & Play Power Supply Series 400W-1200W
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
zite
Low Noise
Medical
Medical Power Supply patents pending
Low Noise 1U size
The Xzite family of low noise medically approved power supplies provides up to
1200W in an extremely compact 1U x 260 x 127mm package. Boasting industry
PLUG & PLAY POWER leading power density of 15W/in3 and efficiencies of up to 90%, the Xzite family
employs an innovative plug & play architecture that allows users to instantly
next generation power source configure a custom power solution in less than 5 minutes!
FEATURES Ideal for acoustic sensitive medical applications the Xzite family provides unmatched
efficiency and high power density, made possible through the combination of low loss
· Low Acoustic Noise 59dBA technologies and the best field-proven technologies in planar magnetics and surface
· UL60601-1 and EN60601-1 approved mount electronics.
· Less than 300µA leakage current
· 4000VAC isolation The Xzite family consists of 3 powerPac models ranging in power levels from 400W to
1200W. Each model may be populated with up to 6 powerMods selected from the
· 1.5V to 58V standard output voltages
table of powerMods shown below.
· Extra low profile: 1U height (40mm)
· Ultra high efficiency, up to 90% All configurations carry full safety agency approvals, UL2601-1, EN60601-1 and are CE
· Plug & Play Power marked. For alternative power interfaces contact support@excelsys.com
- allows fast custom configuration
powerMods powerPacs
- allow easy logistics
MODEL Vmin Vnom Vmax Imax Watts MODEL Watts
· Reduced system heat dissipation
· Series / Parallel of multiple outputs Xg1 1.5 2.5 3.6 50A 125W XZA 600W
Xzite
· 5V bias standby voltage provided Xg2 3.2 5.0 6.0 40A 200W XZB 900W
· Individual output control signals Xg3 6.0 12.0 15.0 20A 240W
XZC 1200W
Xg4 12.0 24.0 30.0 10A 240W
APPLICATIONS INCLUDE Xg5 28.0 48.0 58.0 6A 288W
· Clinical diagnostic equipment
Xg7 5.0 24.0 28.0 5A 120W
· Medical lasers
Xg8 V1 5.0 24.0 28.0 3A 72W
· Dialysis equipment
V2 5.0 24.0 28.0 3A 72W
· For Standard applications see Xcite, Xqite
EFFICIENCY (typical) MECHANICAL SPECIFICATIONS
93 1
92 Third angle projection
91 50.00 97.75
Efficiency %
90
46.00 122.00 92.00
89
88 23.50
SLOT F
87 SLOT E
19.00
J1
70C MAX OPERATING TEMPERATURE
SEE INSTRUCTION MANUAL
INPUT AC 100V-240V 50/60Hz
86
TOP VIEW SLOT D
85 80.00 19.00 127.00
J2
SLOT C
84 19.00
70 85 100 115 130 145 160 175 190 205 220 235 260 SLOT B
Line Voltage VAC 23.50 SLOT A
40.40 29.50
All dimensions in mm.
Mounting Holes
4 M4 threaded holes on Base. Max screw penetration is 6mm from Base.
Series Fleximount Side Mounting Slots
Use with self-clinching studs type FH-M4-X or FH-832-X (X= stud length) from PEM, or equivalent
Alternatively, use Xgen Side Clamps from Excelsys. Part No. Z165 (drawing 61401)
400W-1200W Medical Low Noise AC/DC Plug & Play Power Supply Series
SPECIFICATION applies to configured units consisting of powerMods modules plugged into the appropriate powerPac
INPUT
Parameter Conditions/Description Min Nom Max Units
Input Voltage Range Universal Input 85 264 VAC
120 380 VDC
Low Noise
Input Frequency Range 47 63 Hz
Power Rating XZA 400 W
Medical
XZB Derate linearly from 900W at 120VAC to 600W at 85VAC 900 W
XZC Derate linearly from 900W at 120VAC to 600W at 85VAC 1200 W
Input Current XZA 85VAC in 400W out 7.5 A
XZB 85VAC in 600W out 11.5 A
XZC 85VAC in 600W out 11.5 A
Inrush Current 230VAC @ 25°C 25 A
Undervoltage Lockout Shutdown 65 74 VAC
Fusing XZA 250V F8A HRC
XZB 250V F12A HRC
XZC 250V F12A HRC
OUTPUT
Parameter Conditions/Description Min Nom Max Units
powerMod Power As per powerMod table
Output Adjustment Range Manual: Multi-turn potentiometer. As per powerMod table
Electronic: See Xgen Designers' Manual
Minimum Load 0 A
Line Regulation For ±10% change from nominal line ±0.1 %
Load & Cross Regulation For 25% to 75% load change ±0.2 %
Transient Response For 25% to 75% load change Voltage Deviation 10 %
Settling Time 250 µs
Ripple and Noise 20MHz Bandwidth 1.0 % pk-pk
Overvoltage Protection 1st level: Vset Tracking. 2nd level: Vmax (Latching) 110 125 %
Overcurrent Protection Straight line with hiccup activation at <30% of Vnom 110 120 %
See Designer's Manual for full details
Remote Sense Max. line drop compensation. (except Xg7, Xg8) 0.5 VDC
Overshoot 2 %
Turn-on Delay From AC In / Enable signal 600 / 30 ms
Rise Time Monotonic 5 ms
Hold-up Time For nominal output voltages at full load. XZA / XZB & XZC 20 / 15 ms
Output Isolation Output to Output / Output to Chassis 500 / 500 VDC
GENERAL
Parameter Conditions/Description Min Nom Max Units
Isolation Voltage Input to Output 4000 VAC
Input to Chassis 1500 VAC
Efficiency 230VAC, 1200W @ 24V 90 %
Safety Agency Approvals EN60601-1, UL2601-1, CSA601-1 UL File No. E230761
Leakage Current 250VAC, 60Hz, 25°C 300 µA
Signals See Xgen Series datasheet
Bias Supply Always ON. Current 250mA 4.8 5.0 5.2 VDC
Reliability Failures per million hours at 25°C and full load powerMod 0.98 fpmh
See Designers' Manual. powerPac excludes fans powerPac 0.92 fpmh
EMC
Parameter Standard Level Units
Emissions
Conducted EN55011, EN55022, FCC Level B
Radiated EN55011, EN55022, FCC Level B
Harmonic Distortion EN61000-3-2 Compliant
Flicker and Fluctuation EN61000-3-3 Compliant
Immunity
Electrostatic Discharge EN61000-4-2 Level 4
Radiated RFI EN61000-4-3 Level 3
Fast Transients - burst EN61000-4-4 Level 4
Input Line Surges EN61000-4-5 Class 4
2 Conducted RFI EN61000-4-6 10 V/m
Voltage Dips EN61000-4-11 (EN55024) 10 ms
ENVIRONMENTAL
Parameter Conditions/Description Min Nom Max Units
Operating Temperature -20 +70 °C
Storage Temperature -40 +85 °C
Derating 1.6% per °C above 40°C. See Designers Manual for full deratings
Relative Humidity Non-condensing 5 95 %RH
Acoustic Noise Background noise 28.6dBA, Noise measured 1m from unit 59 dBA
Shock 3000 Bumps, 10G (16ms) half sine
Vibration 1.5G 10 200 Hz
NOTES 1. This product is not intended for use as a stand alone unit and must be installed by qualified personnel.
2. The specifications contained herein are believed to be correct at time of publication and are subject to change without notice.
3. All specifications at nominal input, full load, 25°C unless otherwise stated.
4. See Xgen Designers Manual for detailed power ratings
Doc. 40042 rev. 08 11/09
5. When powering inductive or capacitive loads, it is recommended to use a blocking diode on the output.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Xgen FLEXIBILITY and SIGNALS
Voltage Adjustment - Local Temperature Alarm (Option 01)
The multi-turn potentiometer that adjusts each output within the speci- Open collector signal indicating excessive powerPac temperatures due
fied range may be accessed via the output panel of the power supply. to fan failure or operation beyond ratings. This signal is activated at
Clockwise rotation increases output voltage. Resolution is approximate- least 10ms prior to system shutdown.
ly 5% of nominal voltage (Vnom) per turn.
Fan Fail (Option 01)
Voltage Adjustment - Remote (resistive / electronic) Open collector signal indicating that at least one of the system fans
The output voltage may be adjusted or trimmed by means of an exter- have failed. This does not cause system shutdown.
nal resistor or potentiometer network connected to the Vtrim pin. Linear
Electronic programming is also possible and may be implemented
according to the formula Vout = K Vcontrol. See Xgen series
Designers' Manual for full details.
Paralleling
To achieve increased current capacity, simply parallel outputs using the
standard parallel links. Excelsys `wireless' sharing ensures that current
hogging is not possible. To parallel connect outputs:
1. Switch on IShare switch to ON on powerMods.
2. Connect Negative parallel link.
3. Adjust output voltages of powerMods to within 5mV of eachother. Power Good
4. Connect Positive Parallel Link. Opto-isolated output signal indicates that the powerMod is operating
Parallel Links available to correctly and output voltage is within normal band.
order. Part Number XP1 Opto transistor ON = Good.
Seriesing
To achieve increased output voltages, simply series outputs using stan-
dard series links, paying attention to the requirements to maintain Indication LEDs
SELV levels if required in your system. Each powerMod has a visual indicator to identify that it is operating
Series Links available. Part within normal ratings. Very useful for system diagnosis.
Number XS1
Signal Connector Pinout
Pin J2 (powerPac) J3 (powerMod) J3 (powerMod)
Type A Type B)
Remote Sensing 1 common +sense +pg (V2)
2 +5V bias -sense -pg (V2)
When the load is remote from the power supply, the remote sense
pins may be used to compensate for drops in the power leads. 3 V trim inhibit (V2)
Where the power cabling contributes significant dynamic impedance, 4 ac fail I trim common (V2)
see Xgen series Designers' Manual. 5 fan fail* +inhibit/enable +pg (V1)
6 global enable -inhibit/enable -pg (V1)
Bias Voltage 7 temp alarm* +power good inhibit (V1)
A SELV isolated 5V (always on) bias voltage rated at 250mA is pro- 8 global inhibit -power good common (V1)
vided on J2 to facilitate miscellaneous control functions.
*Option 01 only
Current Limit Adjustment Signal Connector Pinout
The output current limit setting may be adjusted (downwards only) TYPE A Xg1-Xg7 TYPE B : Xg8
by means of an external resistor connection to the I trim pin.
Inhibit/Enable J3 J3
Inhibiting may be implemented either globally or on a per module Voltage V1 Adjust
3 Adjust
basis (powerPac or powerMod inhibiting). Reverse logic (Enabling)
V2 Adjust
may also be implemented, see Xgen series Designers' Manual. 2 1 2 1
J4
J4
AC Fail 4
Open collector signal indicating that the input voltage has failed or is 2
3
less than 80Vac. This signal changes state giving 5mS of warning
before loss of output regulation. See Xgen series Designers' Manual
2
for full specifications.
1
1
M4 Screws
J4 Connector : M4 Screw J4Connector : Camden 9200/4A
J3 Connector Mating Connector J3 Connector Mating Connector
Housing: Locking Molex 51110-0860 Housing: Locking Molex 51110-0860
Non Locking Molex 51110-0850 Non Locking Molex 51110-0850
Crimp Termnal: Molex p/n 50394 Crimp Termnal: Molex p/n 50394
See Xgen series Designers' Manual for full signal connector details.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
Xgen Plug & Play Power Supply Series 200W to 1340W
Series
powerPacs (4slot package, 89mm wide)
Family MODEL Watts Family MODEL Watts
Xlite XLA 200W Xmite XMA 200W
Standard
XLB 400W XMB 400W
Med
XLC 600W XMC 600W
XLD 750W XMD 750W
Xkite XKA 200W Xrite XRA 200W
Noise
Noise
Low
Med
Low
XKB 400W XRB 400W
XKC 600W XRC 600W
powerPacs (6slot package, 127mm wide)
Family MODEL Watts Family MODEL Watts
Xcite XCA 400W Xvite XVA 400W
Standard
XCB 700W XVB 700W
Med
XCC 1000W XVC 1000W
XCD 1200W XVD 1200W
XCE 1340W XVE 1340W
Temp
Xhite XHA 400W Xzite XZA 400W
High
Noise
Med
Low
XHB 600W XZB 900W
Xqite XQA 400W XZC 1200W
Noise
Low
XQB 900W
XQC 1200W
powerMods (for use with all powerPac models)
MODEL Vmin(4) Vnom Vmax(4) Imax Watts
Vtrim Vpot
Xg1 1.0 1.5 2.5 3.6 50A 125W
Xg2 1.5 3.2 5.0 6.0 40A 200W
c
Xg3 4.0 6.0 12.0 15.0 20A 240W erPa
Xg4 8.0 12.0 24.0 30.0 10A 240W
pow
Xg5 8.0 24.0 48.0 58.0 6A 288W
powerMod
Xg7 5.0 5.0 24.0 28.0 5A 120W s
Xg8 V1 5.0 5.0 24.0 28.0 3A 72W
V2 5.0 5.0 24.0 28.0 3A 72W
Part Numbering XVC 1 2 3 4 0 0 - 00 Factory Use
Configured Units may be specified and ordered using the part
numbering system shown opposite. For example, part number Sum of option
4 codes
XVC123400-00 specifies the following 1000W medical power supply.
Model `-' = standard;
· XVC-00 powerPac 1000W medically approved powerPac
`P' = preset
· Xg1 2.5V @ 50A powerMod Slot A
· Xg2 5V @ 40A powerMod
Slot B Slot F
· Xg3 12V @ 20A powerMod
· Xg4 24V @ 10A powerMod Slot C Slot E
Slot D
Accessories .
PowerMods can be parallel connected for higher current and series
connected for higher voltages. Configured units will have parallel and
series links fitted as required.
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de
powerKit
Series
powerKit
powerKit
Ultimate in Plug & Play Power
your dreams come true!
The powerKit family from the Excelsys Xgen series brings user convenience to a
new paradigm for system design engineers tasked with development of system
PLUG & PLAY POWER power supply solutions. The powerKit contains an application specific powerPac
chassis module, along with a selection of user installable plug-in powerMod dc
next generation power source output modules. Each powerMod can be simply plugged in, removed and
exchanged offering a remarkably powerful flexible system solution. Truly, for
FEATURES system design engineers, your dreams come true!
· Make your own custom power supply! The feature-rich powerMods provide a suite of output signals and user configurable
· 1.5V to 58V standard output voltages functions increasing design-in flexibility. User configurable functions include local and
· Only available from Excelsys remote adjusment, adjustable current limit, alternative current limiting technique and
· Straight line or Foldback current limit inhibit/enable functions.
· Output inhibit/enable control
Employing high efficiency conversion techniques, Xgen series powerMods and
· Parallel powerMods for higher current powerPacs have minimal power losses, while the advanced packaging makes the Xgen
· Series powerMods for higher voltages series the smallest power supply in the industry.
· Available in application specific kits
powerKits
EACH powerKit CONTAINS
MODEL powerPac Power Application Slots Ref
· One powerPac
· Seven powerMod dc output modules XKC Xcite 1200W Standard 6 see Xcite datasheet
· Xgen Designers' Manual XKV Xvite 1200W Medical 6 see Xvite datasheet
· Two pairs of parallel links (XP1) XKH Xhite 600W Hi-Temp 6 see Xhite datasheet
· Two series links (XS1) XKQ Xqite 900W Low Noise 6 see Xqite datasheet
· Power & Signal mating connectors
XKL Xlite 600W Standard 4 see Xlite datasheet
· Quality posi screwdriver
XKM Xmite 600W Medical 4 see Xmite datasheet
· Quality Voltage adjustment tool
Each powerKit model contains ONE of each of the following powerMods
MODEL Vmin Vnom Vmax Imax Imin Type Watts *
Xg1 1.5 2.5 3.6 50A 0A A 125W
Xg2 3.2 5.0 6.0 40A 0A A 200W
Xg3 6.0 12.0 15.0 20A 0A A 240W
Xg4 12.0 24.0 30.0 10A 0A A 240W 1
Xg5 28.0 48.0 58.0 6A 0A A 288W
Xg7 5.0 24.0 28.0 5A 0A AB 120W
Xg8 V1 5.0 24.0 28.0 3A 0A B** 72W
V2 5.0 24.0 28.0 3A 0A 72W
*Derate at 2.5% per ° above 50° up to 70° (maximum operating temperature)
C C C
**See powerMod datasheets for details of powerMod types.
All powerKits are provided in an attractive rugged Xgen powerKit case specially
designed for Excelsys to bring a new level of convenience to system engineers
charged with power supply design. Doc. 40043 rev. 01 12/06
CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
info@compumess.de · www.compumess.de · www.netzteile.de