Hier Klicken für das PDF Dokument!!!

XHR 1 kW
   XHR 1 kW Programmable DC Power Supply




Provides 1000 Watts from a 120 Volt / 15 A Outlet                                                                             Xantrex Technology Inc.
                                                                                                                              Headquarters
The Xantrex XHR Series provides 1000 watts of DC power in a compact half-rack package. The                                    8999 Nelson Way
supplies are designed for benchtop and system use, and as an ideal companion for other half-rack                              Burnaby, British Columbia
instruments in a test console - eliminating the need for a blank panel to preserve vertical rack space.                       Canada V5A 4B5
Unique features and size make the XHR ideal for OEM applications where high power and wide                                    800 670 0707 Toll Free
adjustment of output voltage or current is required.                                                                          604 420 1591 Fax

The half-rack XHR comes with a choice of rear and/or front panel connectors for additional system                             5916 195th Street NE
flexibility. The supplies are power factor corrected for low current draw - only 11 A at 120 VAC for                          Arlington, Washington
1000 watts - and reduced generation of input current harmonics. Zero voltage or "soft switching"                              USA 98223
virtually eliminates switching transients and contributes to the high efficiency, low noise and high                          800 446 6180 Toll Free
reliability. The XHR is stackable, with a small footprint, front panel binding post connectors, and a low                     360 925 5144 Fax
current requirement allowing for it to be plugged into a standard 120 VAC, 15 A circuit.

Product Features
  Zero voltage "Soft Switching"
  Power Factor Correction (PFC)
  Simultaneous front panel display of output voltage and current
  Constant voltage or constant current operation
  Choice of front or rear connectors
  Ten-turn front panel knobs
  Standby mode
  Remote sense with 5 V line loss compensation
  LabVIEW® and LabWindows® drivers

Protection Features
  Over voltage protection
  Over temperature protection

Options
  Isolated analog control (ISOL)
  RS-232 interface card
  GPIB interface card
  GPIB-multichannel

                                                                            CompuMess Elektronik GmbH · Lise-Meitner-Str. 1 · D-85716 Unterschleißheim
                                                                            Telefon (089) 32 15 01 - 0 · Telefax (089) 32 15 01 - 11
                                                                            info@compumess.de · www.compumess.de · www.netzteile.de
© 2004 Xantrex Technology Inc. All rights reserved. Xantrex is a trademark of Xantrex International. PN DS20040608R03_xhr1 Printed in Canada www.xantrex.com
XHR 1 kW
    XHR 1 kW Programmable DC Power Supply



    Electrical Specifications 1
   Models                                                       7.5-130        20-50       33-33       40-25        60-18         100-10        150-7        300-3.5        600-1.7
   Output Ratings
       Output Voltage                                           0-7.5 V        0-20 V      0-33 V      0-40 V       0-60 V        0-100 V       0-150 V      0-300 V        0-600 V
       Output Current                                           0-130 A        0-50 A      0-33 A      0-25 A       0-18 A        0-10 A        0-7 A        0-3.5 A        0-1.7 A
       Output Power                                             975 W          1000 W      1089 W      1000 W       1080 W        1000 W        1050 W       1050 W         1020 W
   At the Front Panel Binding Posts
       Output Current                                           0-30 A         0-30 A      0-30A       0-25 A       0-18 A        0-10 A        0-7 A        0-3.5 A        0-1.7 A
       Output Power                                             225 W          600 W       990 W       1000 W       1080 W        1000 W        1050 W       1050 W         1020 W
   Line Regulation 2
       Voltage                                                  1 mV           1 mV        1 mV        1 mV         1 mV          1.5 mV        3 mV         10 mV          20 mV
       Current                                                  5 mA           2 mA        1 mA        1 mA         1 mA          1 mA          0.5 mA       0.5 mA         0.5 mA
   Load Regulation 3
       Voltage                                                  1.5 mV         1.5 mV      1.5 mV      1.5 mV       1.5 mV        2.5 mV        4 mV         10 mV          15 mV V
       Current                                                  15 mA          15 mA       8 mA        7 mA         4 mA          3 mA          3 mA         2.5 mA         2.5 mA
   Meter Accuracy
       Voltage (0.5% of Vmax + 1 count).                        0.05 V         0.2 V       0.3 V       0.3 V        0.7 V         1.1 V         1.6 V        4V             7V
       Current (0.5% of Imax + 1 count)                         0.8 A          0.4 A       0.3 A       0.3 A        0.19 A        0.11 A        0.08 A       0.05 A         0.03 A
   Output Noise (0-20 mHz)
       Voltage (p-p)                                            50 mV          50 mV       50 mV       50 mV        50 mV         50 mV         75 mV        100 mV         300 mV
   Output Ripple (rms)
       Voltage                                                  7.5 mV         5 mV        5 mV        5 mV         5 mV          5 mV          7.5 mV       20 mV          60 mV
   Drift (8 hours) 4
       Voltage (0.05% of Vmax)                                  3.75 mV        10 mV       16.5 mV     20 mV        30 mV         50 mV         75 mV        150 mV         300 mV
       Current (0.1% of Imax)                                   130 mA         50 mA       33 mA       25 mA        18 mA         10 mA         7 mA         3.5 mA         1.7 mA
   Temperature coefficient 5
       Voltage (0.02% of Vmax/°C)                               1.5 mV         4 mV        6.6 mV      8 mV         12 mV         20 mV         30 mV        60 mV          120 mV
       Current (0.03% of Imax/°C)                               39 mA          15 mA       9.9 mA      7.5 mA       5.4 mA        3 mA          2.1 mA       1.1 mA         0.48 mA
   Maximum Remote Sense
       Line Drop Compensation 6                                 3 V/line       5 V/line    5 V/line    5 V/line     5 V/line      5 V/line      5 V/line     5 V/line       5 V/line
   OVP Adjustment Range                                         0-375-8.25 V 1-22 v        1.65-36.3 V 2-44 V       3-66 V        5-110 V       7.5-165 V    15-330 V       30-660 V
       (5% to 110% of Vmax)
   Efficiency 7                                                 81%            83%         83%         83%          84%           84%           85%          85%            85%

1. Specifications indicate typical performance at 25° C ±5°C, nominal line input of 120 VAC.
2. For input voltage variation over the AC input voltage range, with constant rated load.
3. For 0-100% load variation, with constant nominal line voltage. Measured at the rear panel output connector unless stated otherwise.
4. Maximum drift over 8 hours with constant line, load, and temperature, after 30-minute warm-up.
5. Change in output per °C change in ambient temperature, with constant line and load.
6. Line drop is subtracted from total voltage available at supply output.
7. Typical efficiency at 115 VAC input and rated output power.



    General Specifications

    Operational AC Input Voltage                      85-250 VAC, 47-63 Hz; power factor corrected. Derate maximum output power to 900 W for AC input less than 95 V
    Power Factor                                      0.99 minimum for full load and 120 VAC input
    Switching Frequency                               7.5 V to 300 V models: nominal 125 kHz (250 kHz output ripple); 600 V model: nominal 62.5 kHz (125 kHz output ripple)
    Remote Analog Programming                         Voltage and current programming inputs (source must be isolated): 0-5 k, 0-10 k resistances; 0-5 V (default), 0-10 V voltage sources
    Remote Analog Monitoring                          Voltage and current monitor outputs 0-5 V (default), 0-10 V ranges for 0-100% of output
    Dimensions (HxWxD)                                3.4 x 8.5 x 18.6" (86.4 x 216.0 x 472.2 mm)
    Weight (one unit)                                 Approximately 14 lb (6 kg)
    Warranty                                          5 years
    Approvals                                         CE-marked units meet: EN61010-1, EN61000-6-2 and EN6100-6-4; CSA C/US certified to UL61010-1B and CSA C22.2 No 1010.1;
                                                      Meets USA EMC standard: FCC, part 15B, class A; Meets Canadian EMC standard; ICES-001, Class A.


Note: Specifications are subject to change without notice.